Time permitting, we were planning to characterize and test our glycolate oxidase gene using the following assay procedure:

  • Mix 0.94mL of mono-potassium phosphate with 0.6mL of di-potassium phosphate with 90 mL DI H2O to generate 100mL stock solution of potassium phosphate buffer at 8pH.
  • Follow Freeze/Thaw lyse protocol instructions. Note best results happen when using fresh lysate. If not possible follow step and aliquote out smaller volumes to freeze.
  • Create Enzyme Assay master mixture 10mL:
    666.7 micromoles of potassium phosphate
    0.67 micromoles of DCIP
    0.33 mL of 1% PMS
    0.033 - 0.33 mL of cell extract
    = final volume should be ~10 mL
    Aliquote out 1 mL volumes for enzyme assay
  • Create Positive Control 1 mL:
    0.067 micromoles of DCIP
    0.033 mL of 1% PMS
    0.0033 - 0.033 mL of cell extract
    Top off with potassium phosphate buffer for 1 mL volume
  • Create Negative Control 1 mL:
    0.067 micromoles of DCIP
    0.033 mL of 1% PMS
    Top off with potassium phosphate buffer for 1 mL volume
  • Make up a solution of potassium glycolate by mixing Add 10 micromoles of glycolic acid (MW: 76.05 g/mol) to enough buffer to neutralize it to glycolate (this should be enough for three 1 mL cuvette)
  • Measure 600 nm time-lapse spectrophotometer for positive control over 5 mins (Absorbance start at or be under 1)
  • Add 3.33 micromoles of potassium glycolate to the negative control mixture
  • Measure 600 nm time-lapse spectrophotometer for negative control over 5 mins (Absorbance start at or be under 1)
  • Add 3.33 micromoles of potassium glycolate to the enzyme mixture
  • Measure a decrease in extinction at 600 nm time-lapse spectrophotometer over 5 mins (Absorbance start at or be under 1)
Analysis: A decrease in extinction of 0.01 corresponds to oxidation of 1.8 nmoles of glycolate
Adapted from J.M. Lord 1971