To establish a common conversion factor from fluorescence/OD600 to CFU/ml, which acts as a more absolute unit than the relative unit of OD600. We were supplied with six plasmid test constructs each containing an RBS to express a composite part, as well as positive and negative controls. We also received a Standard Measurement Kit in order to create standard curves for converting Abs600 to OD600, an absorption standard curve and a fluorescence standard curve.
Device
Part Number
Negative control
BBa_R0040
Positive Control
BBa_I20270
Test Device 1
BBa_J364000
Test Device 2
BBa_J364001
Test Device 3
BBa_J364002
Test Device 4
BBa_J364007
Test Device 5
BBa_J364008
Test Device 6
BBa_J364009
Results
Volumes of culture and media required for 0.02 starting OD600 Target Abs600 = 0.02, Target volume (mL) = 6
Sample
Abs600
Volume of culture(mL)
Volume of LB + Cam media (mL)
Positive control colony 1
0.1247
2.26
3.74
Positive control colony 2
0.12595
2.21
3.79
Negative control colony 1
0.13665
1.85
4.15
Negative control colony 2
0.13305
1.96
4.04
Device 1 colony 1
0.0959
1.96
4.04
Device 1 colony 2
0.11865
2.56
3.44
Device 2 colony 1
0.161
1.34
4.66
Device 2 colony 2
0.14855
1.56
4.44
Device 3 colony 1
0.1269
2.17
3.83
Device 3 colony 2
0.14105
1.73
4.27
Device 4 colony 1
0.11275
2.92
3.08
Device 4 colony 2
0.0959
1.96
4.04
Device 5 colony 1
0.1061
3.49
2.51
Device 5 colony 2
0.11295
2.91
3.09
Device 6 colony 1
0.1378
1.82
4.18
Device 6 colony 2
0.11935
2.52
3.48
Volumes of culture and media required for 0.1 OD600