Difference between revisions of "Team:HUST-China/InterLab"

Line 2,241: Line 2,241:
 
<link rel="stylesheet" href="https://2018.igem.org/Team:HUST-China/js/changetwo?action=raw&amp;ctype=text/css" type="text/css" "/>
 
<link rel="stylesheet" href="https://2018.igem.org/Team:HUST-China/js/changetwo?action=raw&amp;ctype=text/css" type="text/css" "/>
 
<link rel="stylesheet" href="https://2018.igem.org/Team:HUST-China/js/maizi?action=raw&amp;ctype=text/css" type="text/css"/>
 
<link rel="stylesheet" href="https://2018.igem.org/Team:HUST-China/js/maizi?action=raw&amp;ctype=text/css" type="text/css"/>
   
+
  <script type="text/javascript" src="https://2018.igem.org/Team:HUST-China/js/actionlabel?action=raw&amp;ctype=text/javascript"></script>
  
 
</head>
 
</head>
Line 2,652: Line 2,652:
 
       <img src="https://static.igem.org/mediawiki/2018/archive/5/51/20180915130425%21T--HUST-China--2018-Intelab-pic1.png"  class="img-responsive" >
 
       <img src="https://static.igem.org/mediawiki/2018/archive/5/51/20180915130425%21T--HUST-China--2018-Intelab-pic1.png"  class="img-responsive" >
 
       <img src="https://static.igem.org/mediawiki/2018/5/51/T--HUST-China--2018-Intelab-pic1.png" class="img-responsive" >
 
       <img src="https://static.igem.org/mediawiki/2018/5/51/T--HUST-China--2018-Intelab-pic1.png" class="img-responsive" >
 
+
  <script  src="https://2018.igem.org/Team:HUST-China/js/actionlabel?action=raw&amp;ctype=text/javascript"></script>
  
 
                 </div>
 
                 </div>
Line 2,660: Line 2,660:
 
</div>
 
</div>
 
</section>
 
</section>
 +
 
<!--home-->           
 
<!--home-->           
 
     <footer>
 
     <footer>

Revision as of 07:02, 7 October 2018

HillSide Multi purpose HTML5 Template

Interlab

Introduction

It is significant for synthetic biology to develop a reliable and repeatable measurement, the same to all the other engineering disciplines. We HUST-China have volunteered to test some RBS devices (BCDs) that are intended to make gene expression more precise and reliable by measure the expression level of GFP, in order to help the iGEM community collect data about how reliable will these devices turn out to be in labs around the world.

Provenance and release

What chassis did you use?

Escherichia coli DH5α

What Biosafety Level is your chassis?

BSL1

What PPE did you utilize during your experiments?

T ianming gloves Songxinjiujiu labcoats

Instrument

What instrument did you use during your measurements?

plate reader

Please provide the brand and model of your instrument.

Flexstation 3

Calibration protocol

A1. OD600 reference point-LUDOX protocol

Did you use pathlength correction during measurement? Yes

Number of flashes per well

6

Orbital averaging (nm)

600

What temperature setting did you use during the measurement? 22℃

What type of 96-well plate did you use?

Black plate (preferred)

Did your plate have flat-bottomed or round-bottomed wells?

Flat

Did you use pathlength correction during measurement?

Yes Number of flashes per well 6

Orbital averaging (nm)

600 What temperature setting did you use during the measurement? 22℃ What type of 96-well plate did you use? Black plate (preferred)

Did your plate have flat-bottomed or round-bottomed wells?

Flat

B2. Measurement Steps

❏ Obtain the tube labeled “Silica Beads” from the InterLab test kit and vortex

❏vigorously for 30 seconds. NOTE: Microspheres should NOT bestored at 0°C or below, as freezing affects the properties of the microspheres. If you believe your microspheres may have been frozen, please contact the iGEM Measurement

Committee for a replacement (measurement at igem dot org).

❏ Immediately pipet 96 μL microspheres into a 1.5 mL eppendorf tube

❏ Add 904 μL of ddH2O to the microspheres

❏ Vortex well. This is your Microsphere Stock Solution.

❏Add 100 μl of ddH2O into wells A2, B2, C2, D2....A12, B12, C12, D12

❏Vortex the tube containing the stock solution of microspheres vigorously for 10 seconds

❏Immediately add 200 μl of microspheres stock solution into A1

❏Transfer 100 μl of microsphere stock solution from A1 into A2.

❏Mix A2 by pipetting up and down 3x and transfer 100 μl into A3…

❏Mix A3 by pipetting up and down 3x and transfer 100 μl into A4...

❏Mix A4 by pipetting up and down 3x and transfer 100 μl into A5...

❏Mix A5 by pipetting up and down 3x and transfer 100 μl into A6...

❏Mix A6 by pipetting up and down 3x and transfer 100 μl into A7...

❏Mix A7 by pipetting up and down 3x and transfer 100 μl into A8...

❏ Mix A8 by pipetting up and down 3x and transfer 100 μl into A9...

❏Mix A9 by pipetting up and down 3x and transfer 100 μl into A10...

❏Mix A10 by pipetting up and down 3x and transfer 100 μl into A11...

❏Mix A11 by pipetting up and down 3x and transfer 100 μl into liquid waste

TAKE CARE NOT TO CONTINUE SERIAL DILUTION INTO COLUMN 12.

❏ Repeat dilution series for rows B, C, D

❏ IMPORTANT! Re-Mix (Pipette up and down) each row of your plate immediately

before putting in the plate reader! (This is important because the beads begin to settle to the bottom of the wells within about 10 minutes, which will affect the measurements.) Take care to mix gently and avoid creating bubbles on the surface of the liquid.

❏ Measure Abs600 of all samples in instrument

❏ Record the data in your notebook

❏ Import data into Excel sheet provided (particle standard curve tab)

C1: Fluorescence standard curve - Fluorescein Protocol

Did you use pathlength correction during measurement?

Yes

Number of flashes per well

6

What gain setting did you use?

Automatic

If you used a filter, what light wavelengths did it pass?

530nm

Emission wavelength

525nm

Excitation wavelength

485nm

Fluorescence reading

Bottom optic

What type of 96-well plate did you use?

Black plate (preferred)

Did your plate have flat-bottomed or round-bottomed wells?

Flat

What temperature setting did you use during the measurement?

22℃

C2. Measurement Steps

❏Add 100 μl of PBS into wells A2, B2, C2, D2....A12, B12, C12, D12

❏ Add 200 μl of fluorescein 1x stock solution into A1, B1, C1, D1

❏ Transfer 100 μl of fluorescein stock solution from A1 into A2.

❏ Mix A2 by pipetting up and down 3x and transfer 100 μl into A3…

❏ Mix A3 by pipetting up and down 3x and transfer 100 μl into A4...

❏Mix A4 by pipetting up and down 3x and transfer 100 μl into A5...

❏ Mix A5 by pipetting up and down 3x and transfer 100 μl into A6...

❏ Mix A6 by pipetting up and down 3x and transfer 100 μl into A7...

❏ Mix A7 by pipetting up and down 3x and transfer 100 μl into A8...

❏ Mix A8 by pipetting up and down 3x and transfer 100 μl into A9...

❏ Mix A9 by pipetting up and down 3x and transfer 100 μl into A10...

❏ Mix A10 by pipetting up and down 3x and transfer 100 μl into A11...

❏ Mix A11 by pipetting up and down 3x and transfer 100 μl into liquid waste TAKE CARE NOT TO CONTINUE SERIAL DILUTION INTO COLUMN 12.

❏ Repeat dilution series for rows B, C, D

❏ Measure fluorescence of all samples in instrument

❏ Record the data in your notebook

❏ Import data into Excel sheet provided (fluorescein standard curve tab)

Cell culture setup and meaturement

Transformation:

Negative control BBa_R0040 Kit Plate 7 Well 2D

Positive control BBa_I20270 Kit Plate 7 Well 2B

Test Device 1 BBa_J364000 Kit Plate 7 Well 2F

Test Device 2 BBa_J364001 Kit Plate 7 Well 2H

Test Device 3 BBa_J364002 Kit Plate 7 Well 2J

Test Device 4 BBa_J364007 Kit Plate 7 Well 2L

Test Device 5 BBa_J364008 Kit Plate 7 Well 2N

Test Device 6 BBa_J364009 Kit Plate 7 Well 2P

The initial OD600 measurement of our overnight cultures

What type of media did you use for this step?

Luria Bertani

What type of vessel or container did you use to grow your cells?

50 ml Falcon tube

What temperature setting did you use during the measurement?

22℃

What type of 96-well plates did you use?

Black plates with transparent/clear bottom (preferred)

Flat

Measurement

o Measure OD and fluorescence of all samples

Suggested Plate Layout for 96-well Plate

Interlab result

OD600 reference point

Particle standard curve

Fluorescein standard curve

Raw Plate Reader Measurements