<b>Introduction</b>
 +
<br>
 +
The interlab study was conducted to provide a standardized protocol for measurements of absorbance and fluorescence. We initially had trouble getting our Fluostar Galaxy to work as the program had certain constraints during the setup. Once we familiarized ourselves with how it functioned, we conducted the protocol using black 96 well plates. The first trial of the study was not accepted due to the fluorescence and absorbance readings being too similar between the test devices. The study was conducted once more, but with black wells and transparent bottom plates instead of using fully transparent plates. This submission gave outcomes closer to theoretical results, and was a successful submission.
 +
<br><br>
 
<b>Original Measurement Study</b>
 
<b>Original Measurement Study</b>
 
<br>
 
<br>
Line 19: Line 23:
 
<br>
 
<br>
 
<img src="https://static.igem.org/mediawiki/2018/2/23/T--Bio_Without_Borders--original_cal2.png">
 
<img src="https://static.igem.org/mediawiki/2018/2/23/T--Bio_Without_Borders--original_cal2.png">
 +
<br>
 +
<br>
 
<img src="https://static.igem.org/mediawiki/2018/7/79/T--Bio_Without_Borders--original_cal2_graph2.png">
 
<img src="https://static.igem.org/mediawiki/2018/7/79/T--Bio_Without_Borders--original_cal2_graph2.png">
 
<br>
 
<br>
Line 28: Line 34:
 
<br>
 
<br>
 
<br>
 
<br>
<img src="">
+
<img src="https://static.igem.org/mediawiki/2018/6/6c/T--Bio_Without_Borders--original_cal3_graph1.png">
<img src="">
+
<br>
<img src="">
+
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/e/ed/T--Bio_Without_Borders--original_cal3_graph2.png">
 +
<br>
 +
<br>
 +
Fluorescence of Cell Cultures
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/8/87/T--Bio_Without_Borders--original_fluo.png">
 +
<br>
 +
<br>
 +
Absorbance of Cell Cultures
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/7/75/T--Bio_Without_Borders--original_abs.png">
  
7/27 1:10 Dilution  iGEM Measurement Samples
+
<br>
 +
<br>
 +
<b>Corrected Measurement Study</b>
  
 
<br>
 
<br>
<img src="https://static.igem.org/mediawiki/2018/e/ea/T--Bio_Without_Borders--measurement_dilution.png">
+
<br>
  
 +
<img src="https://static.igem.org/mediawiki/2018/e/e8/T--Bio_Without_Borders--redo_cal1.png">
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/1/1b/T--Bio_Without_Borders--redo_cal2.png">
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/5/57/T--Bio_Without_Borders--redo_cal2_graph1.png">
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/5/58/T--Bio_Without_Borders--redo_cal2_graph2.png">
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/6/60/T--Bio_Without_Borders--redo_cal3.png">
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/c/cc/T--Bio_Without_Borders--redo_cal3_graph1.png">
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/0/03/T--Bio_Without_Borders--redo_cal3_graph2.png">
 +
<br>
 +
<br>
 +
Fluoresence Measurement
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/e/e9/T--Bio_Without_Borders--redo_fluo.png">
 +
<br>
 +
<br>
 +
Absorbance Measurement
 +
<br>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2018/e/e7/T--Bio_Without_Borders--redo_abs.png">
 +
 +
<img src="">
 +
<br>
 +
<br>
 
</p>
 
</p>
 
</div>
 
</div>
 
 
  
  

Latest revision as of 19:10, 12 October 2018

Introduction
The interlab study was conducted to provide a standardized protocol for measurements of absorbance and fluorescence. We initially had trouble getting our Fluostar Galaxy to work as the program had certain constraints during the setup. Once we familiarized ourselves with how it functioned, we conducted the protocol using black 96 well plates. The first trial of the study was not accepted due to the fluorescence and absorbance readings being too similar between the test devices. The study was conducted once more, but with black wells and transparent bottom plates instead of using fully transparent plates. This submission gave outcomes closer to theoretical results, and was a successful submission.

Original Measurement Study

Calibration 1




Calibration 2







Calibration 3







Fluorescence of Cell Cultures



Absorbance of Cell Cultures



Corrected Measurement Study















Fluoresence Measurement



Absorbance Measurement