Interlab

This year, we complete the Interlab along with the Flow Cytometry portion to qualify for the bronze medal. Below you can find our data including the results of our competent cell test kit, background fluorescence information from out samples, and raw data. This year we were also able to utilize our Flow Cytometer as well to submit our flow cytometry data to iGEM. We hope that by submitting our data to iGEM, we can help standardize measuring protocols for reproducibility within experiments.

In this year’s InterLab, our team transformed E. coli DH5α with different plasmids expressing Green Fluorescent Protein (GFP). A plate reader was then used to measure fluorescence and absorbance values from the transformed strains.

Competent Cells Test

Results

Calibration 1: OD600 Reference point with LUDOX Protocol

Table 1. OD600/Abs600 measurements, showing a correction factor of 2.895

Calibration 2: Particle Standard Curve with Microsphere Protocol

After following the Microsphere Protocol, we were able to produce a Particle Standard Curves in order to observe the relationship between Abs600 and amount of particles present.

Figure 1. Particle Standard Curve

Figure 2. Particle Standard Curve (log scale)

From our data, we observed a linear relationship between Abs600 and particle count.

Calibration 3: Fluorescence standard curve with Fluorescence Protocol

Next we were able to utilize the Microsphere Protocol in order to obtain a standard curve for our fluorescence values.

Cell Measurement Protocol

Day One

All cells were transformed into E. coli DH5a based on well locations in kit provided by iGEM.

Day Two

Colonies from the transformation plates were then picked and inoculated in 10.0 mL LB broth + Chloramphenicol resistance. The cells were then incubated overnight at 37°C and shaking at 220 rpm.

Day Three

Followed all protocols provided by iGEM, with extra care during serial dilution steps.