Difference between revisions of "Team:NEU China A/Improve"

 
(13 intermediate revisions by one other user not shown)
Line 1: Line 1:
 
{{NEU_China_A}}
 
{{NEU_China_A}}
 +
{{Template:NEU_China_A/header}}
 
<html>
 
<html>
 +
<style>
 +
    .tooltip {
 +
        font-size: 12px;
 +
        color: #000
 +
    }
  
 +
    .tooltip strong {
 +
        font-weight: 700
 +
    }
  
 +
    .borderleft a {
 +
        color: #03a9f4;
 +
        text-decoration: underline;
 +
    }
 +
</style>
 +
<style>.blu{background-color:#a36dc0 !important;box-shadow:0px 3px 1px #a36dc0 !important} </style>
  
<div class="clear"></div>
+
<div class="section hold"></div>
  
 +
<div style="position:absolute;top: 20;width:100%">
 +
    <div class="row "> 
 +
        <h2 style="padding-left:200px; padding-top:calc(100vh - 250px)">Improved Biobrick</h2>
 +
    </div>
 +
</div>
  
<div class="column full_size">
+
<div class="homeheight">
<h1>Improve</h1>
+
    <div class="parallax-container homeheight">
<p>For teams seeking to improve upon a previous part or project, you should document all of your work on this page. Please remember to include all part measurement and characterization data on the part page on the Registry. Please include a link to your improved part on this page.</p>
+
        <div class="parallax">
 
+
            <img class="responsive-img" src="https://static.igem.org/mediawiki/2018/3/3c/T--NEU_China_A--improve_parts.jpg">
<h3>Gold Medal Criterion #2</h3>
+
        </div>
<p><b>Standard Tracks:</b> Create a new part that has a functional improvement upon an existing BioBrick part. The sequences of the new and existing parts must be different. You must perform experiments with both parts to demonstrate this improvement.  Document the experimental characterization on the Part's Main Page on the Registry for both the existing and new parts. Both the new and existing Main Page of each Part’s Registry entry must reference each other. Submit a sample of the new part to the Registry.
+
 
+
The existing part must NOT be from your 2018 part number range and must be different from the part documented in bronze #4.
+
 
+
<br><br>
+
<b>Special Tracks:</b> Improve the function of an existing iGEM project (that your current team did not originally create) and display your achievement on your wiki.</p>
+
 
+
  
 +
    </div>
 
</div>
 
</div>
  
 
+
<body>
 +
    <div class="container">
 +
        <h3 class="header light-blue-text">Improvement</h3>
 +
        <br />
 +
        <div class="row">
 +
            <div class="s10 offset-s2">
 +
                <p class="borderleft">
 +
                    This year, we chose <a href="http://parts.igem.org/Part:BBa_K381001">BBa_K381001</a> (PyeaR-GFP) as
 +
                    an alternative to our inflammatory sensor, due to promoter PyeaR is sensitive to nitrate and
 +
                    nitrite. When nitrate and nitrite enter E. coli, they will be converted to nitric oxide. Then
 +
                    nitric oxide will bind to the repressor protein NsrR that inactivates PyeaR to inhibit
 +
                    transcription of downstream genes.
 +
                </p>
 +
                <br />
 +
                <p class="borderleft">
 +
                    We learned that the iGEM 2010 Team BCCS-Bristol had used BBa_K381001 to detect the soil nitrate and
 +
                    nitrite to demonstrate the fertility of soil. Thus, farmers can determine which soils are
 +
                    fertilized by detecting the fluorescence of GFP reporter gene. In this way, farmers only need to
 +
                    apply fertilizer in places where there is no fertility, which can save excess fertilizer. Given the
 +
                    economic costs and the impact of eutrophication on ecosystems, the use of BBa_K381001 has great
 +
                    benefits for both agriculture and the environment. However, due to the influence of outdoor
 +
                    temperature, GFP fluorescence density fluctuated significantly. This instability is unfavorable
 +
                    for the detection of soil fertility. In addition, the detection of GFP fluorescence signal requires
 +
                    special equipment that is not readily available for farmers. Therefore, we replaced GFP with blue
 +
                    chromoprotein (amilCP encoded protein) for visual detection. On the one hand, amilCP expression is
 +
                    less affected by temperature and is a more stable reporter than GFP. On the other hand, blue
 +
                    chromoprotein can be visualized by human eyes, instead of requiring the special equipment.
 +
                    Therefore, we believe that our improved part <a href="http://parts.igem.org/wiki/index.php?title=Part:BBa_K2817007">BBa_K2817007</a>
 +
                    is very beneficial to farmers.
 +
                </p>
 +
                <br />
 +
                <p class="borderleft">
 +
                    According to the results of the <a href="https://2016.igem.org/Team:ShanghaiTechChina_B/Project#NO_Sensor">ShanghaiTechChina_B
 +
                        2016 team</a>, 100μM Sodium Nitroprusside Dihydrate (SNP) aqueous solution can continually
 +
                    release NO, and the NO concentration is stable at about 5.5μM. Since our project also tested for
 +
                    inflammatory signals, we chose this concentration before testing for <a href="http://parts.igem.org/Part:BBa_K381001">BBa_K381001</a>
 +
                    and <a href="http://parts.igem.org/wiki/index.php?title=Part:BBa_K2817007">BBa_K2817007</a>.
 +
                </p>
 +
                <br />
 +
                <p class="borderleft">
 +
                    The construction of BBa_K381001 can be seen from Figure 1A. We transformed the plasmid containing
 +
                    BBa_K381001 into DH5α competent E. coli strain and cultured at 37 ℃ overnight to dilute to OD600 =
 +
                    0.4. Then we took half of the bacteria as control and the rest was added SNP aqueous solution, and
 +
                    induced at 37 ℃ for 6 h. Then the fluorescence intensity of cells was observed under microplate
 +
                    reader (Figure 1B) and fluorescence inverted microscope (Figure 1C). The histogram of GFP
 +
                    fluorescent density and microscope images indicated that PyeaR could be effectively activated by NO
 +
                    and there was almost no leakage expression.
 +
                </p>
 +
                <br />
 +
                <div class="center-align">
 +
                    <img class="responsive-img" title="Figure 1. The test of BBa_K381001." src="https://static.igem.org/mediawiki/2018/f/fb/T--NEU_China_A--improve-1.png" />
 +
                </div>
 +
                <p class="tooltip center-align">
 +
                    <strong>Figure 1. The test of BBa_K381001.</strong>
 +
                    <strong>A</strong>, the construction of BBa_K381001.
 +
                    <strong>B</strong>, Histogram of GFP fluorescence: LB control, without SNP, with 100μM SNP.
 +
                    <strong>C</strong>, GFP fluorescence image from top to bottom: without SNP, with 100μM SNP.
 +
                </p>
 +
            </div>
 +
            <br />
 +
            <div class="s10 offset-s2">
 +
                <p class="borderleft">
 +
                    The construction of BBa_K2817007 can be seen from Figure 2A. We transformed the plasmid containing
 +
                    BBa_K2817007 into DH5α, and cultured at 37 ℃ overnight to dilute to OD = 0.4. Then we took half as
 +
                    control and the other half added SNP aqueous solution and induced at 37 ℃ for 6 h. We also set up a
 +
                    negative control group which doesn’t contain amilCP. After 6 h at 37 ℃, 1 mL of the bacterial
 +
                    solution was centrifuged at 8,000 r.p.m for 1 min (Figure 2B). We could directly observe the result
 +
                    of PyeaR being activated by NO without special equipment.
 +
                </p>
 +
                <div class="center-align">
 +
                    <img class="responsive-img" title="Figure 2. The test of BBa_K2817007." src="https://static.igem.org/mediawiki/2018/3/3e/T--NEU_China_A--improve-2.png" />
 +
                </div>
 +
                <p class="tooltip center-align">
 +
                    <strong>Figure 2. The test of BBa_K2817007.</strong>
 +
                    <strong>A</strong>, the construction of BBa_K2817007.
 +
                    <strong>B</strong>, Pellets of bacteria transformed with plasmid containing BBa_K2817007 after induction of 6h. From left to right: negative control group, without SNP group, with 100μM SNP group.
 +
                </p>
 +
                <br />
 +
                <p class="borderleft">
 +
                    In conclusion, we confirmed our improvement through an experimental comparison between the two parts. In the future, we will further confirm the situation of different concentrations of NO and different temperature conditions.
 +
                </p>
 +
            </div>
 +
        </div>
 +
    </div>
 +
</body>
  
 
</html>
 
</html>
 +
{{Template:NEU_China_A/footer}}

Latest revision as of 03:27, 18 October 2018

Improved Biobrick

Improvement


This year, we chose BBa_K381001 (PyeaR-GFP) as an alternative to our inflammatory sensor, due to promoter PyeaR is sensitive to nitrate and nitrite. When nitrate and nitrite enter E. coli, they will be converted to nitric oxide. Then nitric oxide will bind to the repressor protein NsrR that inactivates PyeaR to inhibit transcription of downstream genes.


We learned that the iGEM 2010 Team BCCS-Bristol had used BBa_K381001 to detect the soil nitrate and nitrite to demonstrate the fertility of soil. Thus, farmers can determine which soils are fertilized by detecting the fluorescence of GFP reporter gene. In this way, farmers only need to apply fertilizer in places where there is no fertility, which can save excess fertilizer. Given the economic costs and the impact of eutrophication on ecosystems, the use of BBa_K381001 has great benefits for both agriculture and the environment. However, due to the influence of outdoor temperature, GFP fluorescence density fluctuated significantly. This instability is unfavorable for the detection of soil fertility. In addition, the detection of GFP fluorescence signal requires special equipment that is not readily available for farmers. Therefore, we replaced GFP with blue chromoprotein (amilCP encoded protein) for visual detection. On the one hand, amilCP expression is less affected by temperature and is a more stable reporter than GFP. On the other hand, blue chromoprotein can be visualized by human eyes, instead of requiring the special equipment. Therefore, we believe that our improved part BBa_K2817007 is very beneficial to farmers.


According to the results of the ShanghaiTechChina_B 2016 team, 100μM Sodium Nitroprusside Dihydrate (SNP) aqueous solution can continually release NO, and the NO concentration is stable at about 5.5μM. Since our project also tested for inflammatory signals, we chose this concentration before testing for BBa_K381001 and BBa_K2817007.


The construction of BBa_K381001 can be seen from Figure 1A. We transformed the plasmid containing BBa_K381001 into DH5α competent E. coli strain and cultured at 37 ℃ overnight to dilute to OD600 = 0.4. Then we took half of the bacteria as control and the rest was added SNP aqueous solution, and induced at 37 ℃ for 6 h. Then the fluorescence intensity of cells was observed under microplate reader (Figure 1B) and fluorescence inverted microscope (Figure 1C). The histogram of GFP fluorescent density and microscope images indicated that PyeaR could be effectively activated by NO and there was almost no leakage expression.


Figure 1. The test of BBa_K381001. A, the construction of BBa_K381001. B, Histogram of GFP fluorescence: LB control, without SNP, with 100μM SNP. C, GFP fluorescence image from top to bottom: without SNP, with 100μM SNP.


The construction of BBa_K2817007 can be seen from Figure 2A. We transformed the plasmid containing BBa_K2817007 into DH5α, and cultured at 37 ℃ overnight to dilute to OD = 0.4. Then we took half as control and the other half added SNP aqueous solution and induced at 37 ℃ for 6 h. We also set up a negative control group which doesn’t contain amilCP. After 6 h at 37 ℃, 1 mL of the bacterial solution was centrifuged at 8,000 r.p.m for 1 min (Figure 2B). We could directly observe the result of PyeaR being activated by NO without special equipment.

Figure 2. The test of BBa_K2817007. A, the construction of BBa_K2817007. B, Pellets of bacteria transformed with plasmid containing BBa_K2817007 after induction of 6h. From left to right: negative control group, without SNP group, with 100μM SNP group.


In conclusion, we confirmed our improvement through an experimental comparison between the two parts. In the future, we will further confirm the situation of different concentrations of NO and different temperature conditions.