Line 25: | Line 25: | ||
<p>Figure 2 shows cell number increase over the same simulation as Figure 1. The cell numbers reach very high levels as they are growing nearly exponentially the entire time. Only once the Ethylene glycol is all consumed does the system stabilize as start to decay. Figure 3. shows the degradation of PET as a solid overall in grams, instead of repeat unit concentration like in Figure 1.</p> | <p>Figure 2 shows cell number increase over the same simulation as Figure 1. The cell numbers reach very high levels as they are growing nearly exponentially the entire time. Only once the Ethylene glycol is all consumed does the system stabilize as start to decay. Figure 3. shows the degradation of PET as a solid overall in grams, instead of repeat unit concentration like in Figure 1.</p> | ||
+ | |||
+ | <center> | ||
+ | <img src = "https://static.igem.org/mediawiki/2018/c/c2/T--RHIT--FIG23OMod.png"> | ||
+ | </center> | ||
</div> | </div> | ||
<div class = "column half_size"> | <div class = "column half_size"> | ||
<center> | <center> | ||
− | |||
Figure 2. Simulated Culture Growth on 10 g of PET | Figure 2. Simulated Culture Growth on 10 g of PET | ||
</center> | </center> | ||
Line 36: | Line 39: | ||
<div class = "column half_size"> | <div class = "column half_size"> | ||
<center> | <center> | ||
− | |||
Figure 3. Simulated Consumption of 10 g of PET | Figure 3. Simulated Consumption of 10 g of PET | ||
</center> | </center> | ||
Line 44: | Line 46: | ||
<p>One way to improve this model in the future is by experimentally determining some of the estimated values of PETase and MHETase. Another way is if better methods for converting grams of PET to concentrations, without having to make the assumption of equal accessibility, would be found it could improve the accuracy of the model.</p> | <p>One way to improve this model in the future is by experimentally determining some of the estimated values of PETase and MHETase. Another way is if better methods for converting grams of PET to concentrations, without having to make the assumption of equal accessibility, would be found it could improve the accuracy of the model.</p> | ||
</div> | </div> | ||
+ | |||
+ | <div class = "column full_size"> | ||
+ | <h3>Sensitivity Analysis:</h3> | ||
+ | <p> A basic sensitivity analysis of different chosen and unknown parameters of the model were tested to see their effect on the degradation output. The following table documents the ranges at which these various parameters were biologically relevant. </p> | ||
+ | <center> | ||
+ | <img style="width:75%" src = "https://static.igem.org/mediawiki/2018/1/15/T--RHIT--OverallModelSA.jpg"> | ||