Difference between revisions of "Team:Utrecht"

Line 13: Line 13:
 
<div id = "customelementM">
 
<div id = "customelementM">
 
<h1> Project Description </h1>
 
<h1> Project Description </h1>
 
<p>Bacteria need to respond to a wide range of chemical substances which can be harmful or          beneficial to them. They use sensory proteins that bind and respond to different chemical substances. These proteins are modular and consist of domains that are highly conserved among different species. Several recombinant proteins have been made in the past showing that their potential to be used as engineered biosensors.  Our team will create a living biosensor that can utilize different receptors to detect a broad range of chemicals through an adapted chemotaxis pathway by using bioluminescence. This new diagnostic laboratory tool is re-usable, innovative, inexpensive, flexible, and sustainable compared to current detection systems which often make use of
 
monoclonal antibodies. This new diagnostic laboratory tool is applicable to different areas of research, including concentration-dependent detection of toxins which affect the environment, pathogens, disease states, and pesticides or chemicals affecting agriculture.</p>
 
  
<p>Chemotaxis in <i>E. coli</i> is mediated by a highly conserved, specific, and well-studied  pathway. It consists of a two-component system, in which a receptor activates the kinase autophosphorylation activity of CheA. CheA subsequently donates its phosphoryl group to the response regulator protein CheY, which translocates to the flagellar motor where it interacts with Flim. This interaction results in a change of the rotational direction of the flagellum. As a consequence, the bacteria reorientates itself in a random way.<br>  
+
<p>Humans have been polluting water with natural products for hundreds of years. However, during the last decennia the amount of unnatural chemicals that are being produced, used and carelessly disposed, rapidly increases. The disastrous effects of water pollution by emerging contaminants on animals, humans and environment becomes more and more evident.</p>  
  Our team will utilize the chemotaxis pathway to create a living sensor that can detect a wide range of chemical substances in a way that is cheaper, easier to use, and faster than the currently used antibody based detection methods. We will do this by expressing a kinase dependent split luciferase (KDSL) assay that measures the phosphorylation state of CheY, in an <i>E. coli</i> UU1250 strain that lacks all wild type chemotaxis receptors but expresses proof-of-principle custom made fusion receptors instead. This assay uses a heterodimerizing luciferase which only dimerizes upon binding of a ligand, by abrogating steric hindrance.<br></p>
+
<p>Emerging contaminants are pollutants with a rising concern, for example ecological systems and human health.  
 +
Around a 140.000 kilograms of medical waste a year is present in dutch waters. This leads to huge consequences in ecological systems and human health (Joost van Kasteren, 2016; Nieuwenhuis, 2016). One of the biggest source of the pollution are hospitals (Belfroid et al., 1999). “The possible effects of pharmaceuticals include behavioral changes, tissue damage and effects on reproduction of water organisms, as a result of which the ecosystem as a whole may be disrupted.”- RIVM (Moermond, Smit, van Leerdam, van der Aa, N. G. F. M., & montforts, M. H. M. M., 2016).
 +
The first step in analysing and mitigating the effects is to detect these contaminants in water and locate the source of the contamination.</p>
 +
<p>Currently, a set of biosensors are used. These however are not specific at all. Only stress is detected, after which an alarm will ring. Examples of these biosensors are algae and daphnia. As another disadvantage, the biosensor might get used the pollution, resulting in needing a higher concentration of contaminants before performing stress (Epema, 2018). </p>  
 +
<p>Another example is the microtox-test. It is based on a bioluminescent bacteria: Photobacterium phosphoreum. The bacterium is continuously luminescent, trough metabolizing organic compounds. When stressed by pollutions/contimaniants the bacterium stops metabolising light. If the signal gets below 50%, pollution is confirmed. These pollution however, is quite broad and does not give an indication of the kind of contaminant or any idea about the concentration (ALS global, 2018; Johnson, 2005).</p>
 +
<p>These methods are used by rijkswaterstaat, a company that controls water quality in surface water. For these controls, a limit in concentration is set. If this limit is exceeded, purification of the water needs the find place (Epema, 2018).</p>  
 +
<p>But before surface water becomes surface water, it is cleaned by sewage treatment. However, sewage treatment only focuses on cleaning organic compounds, negletting the pharmaceuticals. An essay indicating which groups of compounds that get in the treatment and out is valuable information indicating the efficiency of the treatment. The ideal biosensor would be one that  can detect specific groups of compounds at once with a direct indication of concentration. With an indication of the toxic compound the search in de mass spectrometer is much easier. This is where our biosensor comes in.</p>
 +
</br>
  
<p>The assay consists of the N-terminal (N-luc2-416) and C-Terminal (C-luc398-550) halves of bacterial luciferase fused to a short linker. This linker consists of CheZ196-214, and CheY53-67 flanked by two 5 amino acid long linker sequences (GGSGG). CheY53-67 contains the D57 residue that is phosphorylated by CheA when the receptor is stimulated due to the binding of a ligand. CheZ196-214 contains the CheY binding site of CheZ. Increased activity of CheA will phosphorylate the D57 residue of CheY53-67. This will allow CheZ196-214 to bind P- CheY53-67. This causes stearic hindrance which prevents the N-luc and C-luc halves of luciferase to reconstitute which abrogates luciferase activity.<br>  
+
<p>We will be using the chemotaxis pathway of the bacteria Escherichia coli. The chemotaxis pathway allows the bacterium to swim towards substances it needs to survive and is mediated by a highly conserved, specific, and well-studied pathway. It consists of a two-component system, a tumbling state, in which the bacteria awaits new stimuli, and a running state, in which it responds to a detected stimulus. When the receptor has no attractant bound, the chemotaxis pathway is constitutively active. In this case the Tar receptor activates the kinase CheA. CheA subsequently transfers its phosphoryl group to the response regulator CheY. Phosphorylated CheY (CheY-P) translocates to the flagellar motor, where it interacts with motor proteins FliM and FliN. This causes the flagellar motor to change its rotational direction, causing the bacterium to tumble. CheY-P is dephosphorylated by CheZ. Upon binding of an attractant, the Tar receptor becomes inactivated and the equilibrium of the pathway is set to low activity, causing the bacterium to switch to a running state.</p>
  We will create two different types of chemotaxis receptors by fusing the ligand binding domains of the cytokinin receptor PcrK, and the epinephrin receptor QseC to the intracellular domain of the <i>E. coli</i> Tar receptor. We opt to use three different fusion points for both receptors based on previously published successful recombinant chemotaxis receptors <sup>[1]</sup>. We will modify these sensors so they can measure different concentrations of ligand by modifying the methyl accepting residues of the Tar methylation helixes, and expressing different levels of recombinant receptor.<br></p>
+
<p>We will perform multiple adjustments to make our biosensor as good as possible.</p>
 
+
<img src="https://static.igem.org/mediawiki/2018/5/53/T--Utrecht--2018--Chemotaxis_Pathway--Main002.png" alt="Chemotaxis_Pathway.png" width  = 500 height = 600>
<p><b>If our proof-of-principle system shows successful concentration-dependent detection of chosen ligands, it will further pave the way for cheap, effective, and modular bacterial-based detection systems.</b></p>
+
<p> As a first step a light signal will be coupled to the binding of a substance with the receptor. A combination of LuxAB and eYFP is used to make BRET (Bioluminescence Resonance Energy Transfer).  In close proximity, luxAB will activate eYFP. EYFP activation results in a detectable light. LuxAB and eYFP proteins are coupled to cq. CheZ and CheY. When no substance is bound, CheY and CheZ bind, causing a light signal to appear.  If a substance binds, the light signal will disappear. The decrease in light signal is a method to detect whether a compound has bind or not.</p>
 +
<img src="https://static.igem.org/mediawiki/2018/c/ce/T--Utrecht--2018--BRET_Assay--Main003.png" alt="BRET_Assay.png" width  = 700 height = 400>  
 +
<p>Secondly we will customize the sensory domain while the rest of the pathway remains intact. As new sensory domain, the adrenaline receptor is used. With this receptor we hope to detect adrenaline and adrenaline-like substances. This concept provides a more broad range of detection with one receptor. Later we hope to change the sensory domain to multiple receptors, allowing to detect more groups of contaminants in water. The ligand binding domains of the cytokinin receptor PcrK, and the epinephrine receptor QseC are similar to the intracellular domain of the E. coli Tar receptor. We opt to use three different fusion points for both receptors based on previously published successful recombinant chemotaxis receptors. We will modify these sensors so they can measure different concentrations of ligand by modifying the methyl accepting residues of the Tar methylation helixes, and expressing different levels of recombinant receptor.</p>
 +
<p>Finally the sensory domain of the biosensor is methylated on 4 sites, resulting in a change in affinity of the receptor. This allows us to measure different concentrations. The methylations will be accomplished with SDM (site directed mutagenesis).</p>
 +
</br>
 +
<p>In conclusion, our biosensor is a cost-effective and durable method to measure emerging contaminants in drinking or surface water. This can be used to detect which contaminants are present and can function as a control step to check if the purification of water succeeded. It will also provide an indication of the concentration level.</p>
 
   
 
   
 
</div>
 
</div>
Line 29: Line 38:
 
<div id = "footer">
 
<div id = "footer">
  
1. Bi, S., Pollard, A. M., Yang, Y., Jin, F., & Sourjik, V. (2016). Engineering hybrid chemotaxis receptors in bacteria. ACS synthetic biology, 5(9), 989-1001.
+
insert references
  
 
</div>
 
</div>

Revision as of 08:25, 13 August 2018

Project Description

Humans have been polluting water with natural products for hundreds of years. However, during the last decennia the amount of unnatural chemicals that are being produced, used and carelessly disposed, rapidly increases. The disastrous effects of water pollution by emerging contaminants on animals, humans and environment becomes more and more evident.

Emerging contaminants are pollutants with a rising concern, for example ecological systems and human health. Around a 140.000 kilograms of medical waste a year is present in dutch waters. This leads to huge consequences in ecological systems and human health (Joost van Kasteren, 2016; Nieuwenhuis, 2016). One of the biggest source of the pollution are hospitals (Belfroid et al., 1999). “The possible effects of pharmaceuticals include behavioral changes, tissue damage and effects on reproduction of water organisms, as a result of which the ecosystem as a whole may be disrupted.”- RIVM (Moermond, Smit, van Leerdam, van der Aa, N. G. F. M., & montforts, M. H. M. M., 2016). The first step in analysing and mitigating the effects is to detect these contaminants in water and locate the source of the contamination.

Currently, a set of biosensors are used. These however are not specific at all. Only stress is detected, after which an alarm will ring. Examples of these biosensors are algae and daphnia. As another disadvantage, the biosensor might get used the pollution, resulting in needing a higher concentration of contaminants before performing stress (Epema, 2018).

Another example is the microtox-test. It is based on a bioluminescent bacteria: Photobacterium phosphoreum. The bacterium is continuously luminescent, trough metabolizing organic compounds. When stressed by pollutions/contimaniants the bacterium stops metabolising light. If the signal gets below 50%, pollution is confirmed. These pollution however, is quite broad and does not give an indication of the kind of contaminant or any idea about the concentration (ALS global, 2018; Johnson, 2005).

These methods are used by rijkswaterstaat, a company that controls water quality in surface water. For these controls, a limit in concentration is set. If this limit is exceeded, purification of the water needs the find place (Epema, 2018).

But before surface water becomes surface water, it is cleaned by sewage treatment. However, sewage treatment only focuses on cleaning organic compounds, negletting the pharmaceuticals. An essay indicating which groups of compounds that get in the treatment and out is valuable information indicating the efficiency of the treatment. The ideal biosensor would be one that can detect specific groups of compounds at once with a direct indication of concentration. With an indication of the toxic compound the search in de mass spectrometer is much easier. This is where our biosensor comes in.


We will be using the chemotaxis pathway of the bacteria Escherichia coli. The chemotaxis pathway allows the bacterium to swim towards substances it needs to survive and is mediated by a highly conserved, specific, and well-studied pathway. It consists of a two-component system, a tumbling state, in which the bacteria awaits new stimuli, and a running state, in which it responds to a detected stimulus. When the receptor has no attractant bound, the chemotaxis pathway is constitutively active. In this case the Tar receptor activates the kinase CheA. CheA subsequently transfers its phosphoryl group to the response regulator CheY. Phosphorylated CheY (CheY-P) translocates to the flagellar motor, where it interacts with motor proteins FliM and FliN. This causes the flagellar motor to change its rotational direction, causing the bacterium to tumble. CheY-P is dephosphorylated by CheZ. Upon binding of an attractant, the Tar receptor becomes inactivated and the equilibrium of the pathway is set to low activity, causing the bacterium to switch to a running state.

We will perform multiple adjustments to make our biosensor as good as possible.

Chemotaxis_Pathway.png

As a first step a light signal will be coupled to the binding of a substance with the receptor. A combination of LuxAB and eYFP is used to make BRET (Bioluminescence Resonance Energy Transfer). In close proximity, luxAB will activate eYFP. EYFP activation results in a detectable light. LuxAB and eYFP proteins are coupled to cq. CheZ and CheY. When no substance is bound, CheY and CheZ bind, causing a light signal to appear. If a substance binds, the light signal will disappear. The decrease in light signal is a method to detect whether a compound has bind or not.

BRET_Assay.png

Secondly we will customize the sensory domain while the rest of the pathway remains intact. As new sensory domain, the adrenaline receptor is used. With this receptor we hope to detect adrenaline and adrenaline-like substances. This concept provides a more broad range of detection with one receptor. Later we hope to change the sensory domain to multiple receptors, allowing to detect more groups of contaminants in water. The ligand binding domains of the cytokinin receptor PcrK, and the epinephrine receptor QseC are similar to the intracellular domain of the E. coli Tar receptor. We opt to use three different fusion points for both receptors based on previously published successful recombinant chemotaxis receptors. We will modify these sensors so they can measure different concentrations of ligand by modifying the methyl accepting residues of the Tar methylation helixes, and expressing different levels of recombinant receptor.

Finally the sensory domain of the biosensor is methylated on 4 sites, resulting in a change in affinity of the receptor. This allows us to measure different concentrations. The methylations will be accomplished with SDM (site directed mutagenesis).


In conclusion, our biosensor is a cost-effective and durable method to measure emerging contaminants in drinking or surface water. This can be used to detect which contaminants are present and can function as a control step to check if the purification of water succeeded. It will also provide an indication of the concentration level.