Difference between revisions of "Team:Valencia UPV/Experiments"

Line 210: Line 210:
 
                                 <ul>
 
                                 <ul>
 
                                     <p>In this experiment we wanted to test the feasibility of the concept of breaking the seal we put in pipette tips and blowing through the synge to get the contents out.</p>
 
                                     <p>In this experiment we wanted to test the feasibility of the concept of breaking the seal we put in pipette tips and blowing through the synge to get the contents out.</p>
                                    <li>
+
                                         <p>Materials:</p>
                                         <p><i>Materials:</i></p>
+
 
                                         <ul>
 
                                         <ul>
 
                                             <li>
 
                                             <li>
Line 235: Line 234:
 
                                             </li>
 
                                             </li>
 
                                         </ul>
 
                                         </ul>
                                    </li>
+
                                         <p>Procedure:</p>
                                    <li>
+
                                         <p><i>Procedure:</i></p>
+
 
                                         <ol>
 
                                         <ol>
 
                                             <li>
 
                                             <li>
Line 255: Line 252:
 
                                             </li>
 
                                             </li>
 
                                         </ol>
 
                                         </ol>
                                    </li>
 
 
                                 </ul>
 
                                 </ul>
 
                                 <!-- Digital microfluidics -->
 
                                 <!-- Digital microfluidics -->
Line 263: Line 259:
 
                                 <ul>
 
                                 <ul>
 
                                     <p>For the first experiment of droplet movement the objective was to determine the important parameters that affect this technology.</p>
 
                                     <p>For the first experiment of droplet movement the objective was to determine the important parameters that affect this technology.</p>
                                     <li>
+
                                      
                                         <p><i>Materials:</i></p>
+
                                         <p>Materials:</p>
 
                                         <ul>
 
                                         <ul>
 
                                             <li>
 
                                             <li>
Line 280: Line 276:
 
                                         </ul>
 
                                         </ul>
 
                             </p>
 
                             </p>
                             </li>
+
                              
                             <li>
+
                              
                                 <p><i>Procedure:</i></p>
+
                                 <p>Procedure:</p>
 
                                 <ol>
 
                                 <ol>
 
                                     <li>
 
                                     <li>
Line 303: Line 299:
 
                                     </li>
 
                                     </li>
 
                                 </ol>
 
                                 </ol>
                             </li>
+
                              
 
                             <p>For the second iteration of droplet movement test the objective was to add automation to the movement:</p>
 
                             <p>For the second iteration of droplet movement test the objective was to add automation to the movement:</p>
                             <li>
+
                              
                                 <p><i>Materials:</i></p>
+
                                 <p>Materials:</p>
 
                                 <ul>
 
                                 <ul>
 
                                     <li>
 
                                     <li>
Line 327: Line 323:
 
                                     </li>
 
                                     </li>
 
                                 </ul>
 
                                 </ul>
                            </li>
+
                                 <p>Procedure:</p>
                            <li>
+
                                 <p><i>Procedure:</i></p>
+
 
                                 <ol>
 
                                 <ol>
 
                                     <li>
 
                                     <li>
Line 350: Line 344:
 
                                     </li>
 
                                     </li>
 
                                 </ol>
 
                                 </ol>
                             </li>
+
                              
 
                             <p>Extending onto the previous experiment we designed a PCB that would serve as the surface from printeria. This time we used 6 concatenated IC.</p>
 
                             <p>Extending onto the previous experiment we designed a PCB that would serve as the surface from printeria. This time we used 6 concatenated IC.</p>
                             <li>
+
                              
                                 <p><i>Materials:</i></p>
+
                                 <p>Materials:</p>
 
                                 <ul>
 
                                 <ul>
 
                                     <li>
 
                                     <li>
Line 374: Line 368:
 
                                     </li>
 
                                     </li>
 
                                 </ul>
 
                                 </ul>
                             </li>
+
                              
                             <li>
+
                              
                                 <p><i>Procedure:</i></p>
+
                                 <p>Procedure:</p>
 
                                 <ol>
 
                                 <ol>
 
                                     <li>
 
                                     <li>
Line 397: Line 391:
 
                                     </li>
 
                                     </li>
 
                                 </ol>
 
                                 </ol>
                             </li>
+
                              
 
                             </ul>
 
                             </ul>
 
                             <!-- Hot/cold zone -->
 
                             <!-- Hot/cold zone -->
Line 407: Line 401:
 
</p>
 
</p>
 
                             <ul>
 
                             <ul>
                                 <li>
+
                                  
                                     <p><i>Materials:</i></p>
+
                                     <p>Materials:</p>
 
                                     <ul>
 
                                     <ul>
 
                                         <li>
 
                                         <li>
Line 468: Line 462:
 
                                         </li>
 
                                         </li>
 
                                     </ul>
 
                                     </ul>
                                 </li>
+
                                  
                                 <li>
+
                                  
                                     <p><i>Procedure:</i></p>
+
                                     <p>Procedure:</p>
 
                                     <ol>
 
                                     <ol>
 
                                         <li>
 
                                         <li>
Line 515: Line 509:
 
                                         </li>
 
                                         </li>
 
                                     </ol>
 
                                     </ol>
                                 </li>
+
                                  
 
                             </ul>
 
                             </ul>
 
                             <!-- Electroporator -->
 
                             <!-- Electroporator -->
Line 523: Line 517:
 
                             <ul>
 
                             <ul>
 
                                 <p>On this experiment the objective was to test the electroporator module for Printeria.</p>
 
                                 <p>On this experiment the objective was to test the electroporator module for Printeria.</p>
                                 <li>
+
                                  
                                     <p><i>Materials:</i></p>
+
                                     <p>Materials:</p>
 
                                     <ul>
 
                                     <ul>
 
                                         <li>
 
                                         <li>
Line 539: Line 533:
 
                                         </li>
 
                                         </li>
 
                                     </ul>
 
                                     </ul>
                                 </li>
+
                                  
                                 <li>
+
                                  
                                     <p><i>Procedure:</i></p>
+
                                     <p>Procedure:</p>
 
                                     <p>To test the electroporation module, we transformed 10G electrocompetent cells with 1 to 2 <meta charset="utf-8"> &mu;L of the <a href="http://parts.igem.org/Part:BBa_K2656105" target="_blank">BBa_K26560105</a> transcriptional unit previously assembled into an alpha GoldenBraid vector (KmR). Thus, this plasmid express the sfGFP protein and so express fluorescence under UV light.</p>
 
                                     <p>To test the electroporation module, we transformed 10G electrocompetent cells with 1 to 2 <meta charset="utf-8"> &mu;L of the <a href="http://parts.igem.org/Part:BBa_K2656105" target="_blank">BBa_K26560105</a> transcriptional unit previously assembled into an alpha GoldenBraid vector (KmR). Thus, this plasmid express the sfGFP protein and so express fluorescence under UV light.</p>
 
                                     <ol>
 
                                     <ol>
Line 563: Line 557:
 
                                         </li>
 
                                         </li>
 
                                     </ol>
 
                                     </ol>
                                 </li>
+
                                  
 
                             </ul>
 
                             </ul>
 
                             <a class="anchorOffset" id="imCharact"></a>
 
                             <a class="anchorOffset" id="imCharact"></a>

Revision as of 23:03, 17 October 2018

Stack Multipurpose HTML Template

Experiments

During the development of Printeria, experimentation has been one of the fundamental aspects in each step of our project. The design of new experiments and protocols has allowed us to validate the results obtained from the device or the laboratory with the theoretical schemes and to guarantee the repeatability of each experience. These experiments were intended to cover three key objectives of the project:

  • To demonstrate the functioning of the Printeria device through the concept tests of the technologies separately and through the tests and protocols related to Printeria established in the Web Lab.

  • Characterize the parts in an experimental way in order to include the maximum information in our Printeria Part Collection.

  • Obtain as much information as possible about the reporter proteins commonly used in Web Lab experiments, such as GFP, YFP or sfGFP.

Check the results of our experiments yourself...

Printeria protocols & experiments

Printeria Wet Lab

In regard to the lab work, several lines of experiments have been carried out with the objective of ensuring the biological functioning of Printeria. We have kept a record of our daily lab work through different notebooks, so you can access the documents for each group of experiments by clicking their respective buttons.

You can also read the collection of protocols we have followed to proceed with our experiments, so they could be easily repeated by future iGEM teams.

Level 0 assembly (DNA Basic parts adaptation)

Printeria needs a toolkit of DNA basic parts adapted to be assembled with the Golden Gate assembly method. We have designed them as they appear on our Design page. You can check the chronological construction phases of these parts going to:

Destination vector experiments

We have done several experiments to select the way to introduce the Level 1 destination plasmid, in order to obtain the lowest number of bacteria without the desired insert resulting from the Golden Gate assembly reaction, and thus trying to avoid the necessity of the plate screening step. The progressive process of decision has been recorded in our:

Experiments with competent cells

Several experiments were done to decide how to introduce the E. coli chassis into Printeria. It included transformation efficiency experiments with freeze drying competent cells and with competent cells maintained at -20ºC and room temperature. All the experiments are chronologically listed in our:

Level 1 assembly (Composite Parts Assembly)

In order to characterize our DNA basic parts, we had to assemble composite parts using the Golden Gate technology (Level 1 assembly) with our DNA basic part collection. By this way we were able to check the robustness of the protocol and to verify that its efficiency was high enough to be done by Printeria.

pBioBrickator plasmid construction and composite parts adaptation

As it is explained in the Part Collection page , we have designed the BBa_K2656200 vector, adapted from the standard pSB1C3 backbone, to convert our Golden Gate transcriptional units to BioBricks. Thus, we were able to introduce each transcriptional unit into a BioBrick compatible vector with a Type IIS enzyme reaction. This process can be checked going to:

Printeria device

In the Printeria project, the experiments carried out on the machine developed by the Printeria Hardware team stand out in importance. With them, we have tried to verify the automation process that our device offers to the user. Below are described both the materials and the procedures of the most important experiments our Printeria equipment.

Input system

    In this experiment we wanted to test the feasibility of the concept of breaking the seal we put in pipette tips and blowing through the synge to get the contents out.

    Materials:

    • Arduino

    • Peristaltic pump

    • Solenoid

    • Syringe

    • Input carrousel

    • Stepper motor

    • Sealed pipette tips

    Procedure:

    1. The pipette tips are loaded with 4 μL of liquid and are placed in place on the input carrousel.

    2. The stepper motor spins it to get the filled pipette tips under the syringe.

    3. The solenoid is activated, moving down the syringe into the tip.

    4. The pump blows filtered air into the tip, releasing the liquid.

Digital microfluidics

    For the first experiment of droplet movement the objective was to determine the important parameters that affect this technology.

    Materials:

    • HV supply

    • Pad prototype PCB 1

    • Parafilm

    • Silicone oil

    Procedure:

    1. A thin layer of silicone oil is placed on top of the pads of the PCB.

    2. The parafilm is stretched to be as thin as possible.

    3. Another layer of silicone oil is placed on top of the parafilm.

    4. 15 μL of water are placed on top of one of the pads.

    5. We manually connected and disconnected wires from the HV voltage supply set at 300 V.

    For the second iteration of droplet movement test the objective was to add automation to the movement:

    Materials:

    • HV supply

    • Pad prototype PCB 2

    • IC: HV507

    • Arduino

    • Parafilm

    • Silicone oil

    Procedure:

    1. A thin layer of silicone oil is placed on top of the pads of the PCB.

    2. The parafilm is stretched to be as thin as possible.

    3. Another layer of silicone oil is placed on top of the parafilm.

    4. 15 μL of water are placed on top of one of the pads.

    5. Using the arduino we send commands of which pad to turn on, moving the droplet

    Extending onto the previous experiment we designed a PCB that would serve as the surface from printeria. This time we used 6 concatenated IC.

    Materials:

    • HV supply

    • Pad prototype PCB final

    • IC: HV507

    • Arduino

    • Parafilm

    • Silicone oil

    Procedure:

    1. A thin layer of silicone oil is placed on top of the pads of the PCB.

    2. The parafilm is stretched to be as thin as possible.

    3. Another layer of silicone oil is placed on top of the parafilm.

    4. 15 μL of water are placed on top of one of the pads.

    5. Using the arduino we send commands of which pad to turn on, moving the droplet.

Hot/cold zone

The objective of this experiment is to test the concept of a hot and cold zone to replace a thermocycler.

    Materials:

    • Peltier device

    • Power resistor

    • Arduino

    • Variable voltage power supply

    • IRFZ44N mosfet

    • Thermistors

    • 2k2 and 10k resistors

    • Intel stock cooler

    • BBa_P10500 plasmid

    • gBlock of BBa_K2656024 adapted to be assembled into P10500

    • BsmBI endonuclease

    • T4 DNA ligase

    • Bovine serum albumine

    • T4 DNA ligase buffer

    • 10G electrocompetent cells

    • Electroporator

    • Electroporation cuvette

    • LB-agar plates with Kanamycin

    • SOC recovery medium

    Procedure:

    1. Assemble the circuit.

    2. Set up the reaction following the Golden Gate assembly protocol.

    3. Pipette the drop where the reaction is taking place between the zone at 16ºC and the one at 37ºC during 25 cycles following these times:

    4. Golden Gate assembly reaction protocol. That schema must be run 25 cycles.

      Temperature (ºC)

      Time (minutes)

      37

      3

      16

      4

    5. Transform the electrocompetent cells with 9 μL of the reaction result.

Electroporator

    On this experiment the objective was to test the electroporator module for Printeria.

    Materials:

    • Electroporator PCB

    • Arduino

    • HV Supply

    • Curvette

    Procedure:

    To test the electroporation module, we transformed 10G electrocompetent cells with 1 to 2 μL of the BBa_K26560105 transcriptional unit previously assembled into an alpha GoldenBraid vector (KmR). Thus, this plasmid express the sfGFP protein and so express fluorescence under UV light.

    1. Pipette 1 μL of DNA (80.5 ng/ μL) into 50 μL 10G aliquot

    2. Transfer into the electroporation cuvette

    3. Turn on the electroporation module, with 5 ms of set point and 1.5 kV.

    4. Add 700 μL SOC liquid medium and incubate for 1h with vigorous shaking

    5. Plate 300 μL into agar plate with kanamycin antibiotic

    6. Incubate for 16-18h at 37ºC

Parts characterization

This year, Valencia UPV iGEM team has designed an extensive Part Collection in purpose of allowing the user to design multiple genetic constructions and experiments. One of our main objectives has been to show the user clear and structured information about the pieces that make up the Printeria kit. For this reason, we have considered the characterization of the parts as a priority when developing the project. In this way, we have elaborated an experimental protocol which have allowed us to systematically obtain and structure information from the parts.

Experimental protocol

The Printeria Modeling and Lab team and have jointly designed an experimentation protocol for the laboratory experiments. Thanks to it, and from the colonies of the different TU the experimental data can be obtained, processed and ready to be optimized.

Materials:

  • Printeria transcriptional units (see our Printeria Part Collection)

  • Measuring equipment: Biotek Cytation3

  • 96 well plate

  • MATLAB 2018a software

Protocol:

  1. A colony or a Glycerol stock corresponding to a TU assembled by our Lab team is used to inoculate LB culture medium (with the appropriate antibiotic, in the cases of the TU, with Kanamycin) and grow overnight at 37ºC and 250 r.p.m.

  2. A 10:1 dilution of the culture is performed changing the culture media to M9 minimal medium and grow for 4 hours at 37ºC and 250 r.p.m.

  3. The culture is chilled in an ice-water bath anfd the optical density at 600nm (OD600) of the culture is measured with a spectrophotometer. Then a calculation is performed (using this Excel sheet) to make a dilution in order to bring the OD600 of the culture to 0.1OD600 with the appropriate culture volume to inoculate 8 replicas into 200uL wells.

  4. The experiment is designed on the measuring equipment. In our case, we use the Biotek Cytation3 equipment. We establish the equipment parameters.

    Parameters

    Description

    Time

    06:00:00 (HH:MM:SS) usually. Measurement interval: 05:00 (MM:SS)

    Number of samples

    We normally set 8 samples of reporter protein for each TU colony

    Number of medium samples

    We normally set 8 samples of medium. We normally use LB or M9 medium with Kanamycin

    Temperature

    37 ºC

    Shake

    Double Orbital. Continuously. We shake the plate before each measure

    Absorbance. Optical Density (OD) measure

    Wavelenght at 600 nm emission

    Excitacion wavelength

    We normally set 485 nm for GFP or sfGFP and 500 nm for YFP

    Emission wavelength

    We normally set 528 nm for GFP or sfGFP and 540 nm for YFP

    Gain (G)

    Normally the gain value is G = 60, although for proteins with lower fluorescence, it is recommended that G takes higher values.

    Biotek Cytation 3 experiment parameters

  5. Samples are introduced into the 96 well plate and the experiment begins.

  6. After the experiment, fluorescence and absorbance data obtained are exported to an Excel file.

  7. We run the MATLAB convert_data.m script. This script uses several additional MATLAB files with which:

    1. We extract the fluorescence and absorbance matrices from the Excel file (see readExperiment3.m MATLAB function).

    2. We apply the corrections to the data (see plotExperiment_yb.m MATLAB function).

    3. We save the data of FOD, OD, molecules and time in a .mat format file.

Experiments changing RBS

We have designed two experiments following the same experimental protocol. In them we have assembled different Printeria TU with the same promoters, CDS (sfGFP reporter protein) and transcriptional terminator, but with different RBS. These experiments were used in our modeling to complete the characterization of the part in the Printeria Collection.

Printeria RBS:

Experiment 1 changing RBS. Experimental data of strong, medium and weak protein expression RBS
Experiment 2 changing RBS. Experimental data of strong and very weak protein expression RBS
Experiment 2 changing RBS. Experimental data of very weak protein expression RBS
Experiments changing promoters

We have designed an experiment following the experimental protocol. In them we have assembled different Printeria TU with the same RBS, CDS (GFP reporter protein) and transcriptional terminator, and with different promoters. After obtaining the results, and following the optimization protocol, we have obtained the parameters of the model and have validated our model.

Printeria promoters:

Experiment 1 changing promoters. Experimental data of strong, medium and weak promoters.
Experiment to compare reporter proteins with and without LVA tag

In this experiment, that we have performed following the experimental protocol, we have designed two TU. Both have the same promoters, RBS and transcriptional terminators, but different CDS. The CDS express the reporter protein YFP, however, one of them has a degradation LVA tag, which causes faster degradation.

The experimental TU and experimetal results are shown below.

YFP reporter protein:

Experiment 1 YFP vs. YFP LVA tag. Experimental data of YFP and YPF LVA tag reporter proteins.

Reporter proteins comparisons

The reporter proteins are one of the essential elements in the experimentation process of the Valencia UPV iGEM team. Thanks to them, we can quantify the protein expression of our modified bacteria, and relate it to the theoretical models designed. Proteins such as GFP, YFP, sfGFP, mRFP... are the proteins that provide us with information about the Printeria product, and that we want to show our user.

For this reason, the Printeria Modeling team and Web Lab have jointly elaborated a series of experimental procedures to obtain new information on reporter proteins and apply it in the treatment of experimental data.

Procedure for obtaining protein spectra

Obtaining excitation and emission spectra is a fundamental aspect in the process of characterization of a fluorescent protein. Each protein has a characteristic spectrum, which indicates the energy in which the molecule is excited or emits at a certain wavelength.

The characterization of the reporter proteins by excitation and emission spectra are of great importance in experimentation. When contrasting experimental information with the theoretical results of mathematical models, we experiment with numerous reporter proteins, such as fluorescence proteins or chromoproteins. However, the fluorescence data obtained must be corrected applying diferent operations in order to obtain representative fluorescence data:

  1. The subtraction of the medium fluorescence:

  2. The quotient of the fluorescence with the gain:

  3. The quotient of the fluorescence with excitation and emission efficiency:

Correction process of fluorescence data

Until now, the corrections applied to the experiments performed with these reporter proteins were the subtraction of the fluorescence of the medium, and the division by the gain factor of the measuring equipment. However, with the protein spectra we can also normalize the fluorescence data to values that would have been obtained with maximum excitation and emission.

Owing to this reason, a protocol has been established in the lab by Lab and Modeling team to obtain the spectrum of any reporter protein.

Materials:

  • Measuring equipment: Biotek Cytation3

  • 96 well plate

  • MATLAB 2018a software

Procedure:

  1. We look for the theoretical spectra of the protein to be measured or similar molecules in order to determine the wavelength at which the protein is excited or emitted at maximum energy, i.e. where the theoretical spectral peaks occurs.

  2. We define the protocol of our equipment to get the absorbance and fluorescence dataset. In our protocol, the most important parameters to be established are summarized in the following Table.

    Parameters

    Description

    Number of samples

    From 3 to 6 samples of reporter protein and 3 samples of medium (LB or M9 medium)

    Temperature

    37 ºC

    Shake

    Double Orbital. 01:00 (MM:SS)

    Absorbance. Optical Density (OD)

    Wavelenght at 600 nm emission

    Excitacion and emission scans

    The scans occur between two wavelength limit values. The established range will depend on the theoretical spectrum of the protein.

    Excitacion and emission wavelengths

    These values will depend on the range, and therefore on the spectrum. Values far from the theoretical peak lead to more attenuated fluorescence curves, and values very close to the peak can lead to overlap and error in reading the data. Therefore, a compromise must be reached between curve resolution and reading overlap.

    Gain (G)

    Normally the gain value is G = 60, although for proteins with lower fluorescence, it is recommended that G takes higher values.

    Experimental parameters

  3. The experiment is introduced, and the experimental absorbance data and the fluorescence curves of the samples are obtained with the medium fluorescence correction applied.

  4. The dataset is exported to an Excel file.

  5. The MATLAB script spectrum.m for fluorescent proteins is executed:

    1. Dataset is extracted from the Excel file. We discard readings that have suffered overlap, or that take negative values.

    2. The fluorescence curves of all samples are averaged, and the result is normalised (from 0 to 100%).

    3. Graphs of the normalized absorption and emission spectra are plotted. The X-axis represents the wavelength (nm), and the Y-axis represents the normalized fluorescence intensity (%).

In practical terms, the protocol has been applied to all of our reporter proteins: GFP, sfGFP, YFP and mRFP. All results can be found in our parts collection as well as in the iGEM catalog.

GFP spectra
sfGFP spectra
YFP spectra
mRFP spectra

In the particular case of a reporter chromoprotein, such as amilCP, we do not measure fluorescence, but absorbance. In this case, in rder to obtain the corrected absorbance curve, we must subtract from the cell absorbance data with the reporter protein the absorbance of a medium with cells without chromoprotein. Once the data have been corrected, we normalize them between values of 0 and 100 and with this we elaborate the graph. The protocol used can be found in the MATLAB script amilCP_spectrum.m.

amilCP spectra

Finally, we have also obtained the spectra of the fluorescein molecule. These spectra have been used to correct the fluorescence data used in the Interlab Study to obtain the Relative Fluorescence Units (RFU) to Molecules of Equivalent Fluorochrome (MEFL) conversion factor. In addition, the comparison between GFP and sfGFP proteins RFU has been possible thanks to fluorescein spectra.

Parameters

Value

Number of samples

6 samples. 3 samples of medium (LB or M9 medium)

Temperature

37 ºC

Shake

Double Orbital. 01:00 (MM:SS)

Absorbance. Optical Density (OD)

Wavelenght at 600 nm emission

Emission range

[495 - 580] nm

Fixed excitation wavelength

480 nm

Excitation range

[430 - 520] nm

Fixed emission wavelength

545 nm

Gain (G)

60

Experimental parameters
Fluorescein spectra

Comparison between sfGFP, GFP and YFP relative fluorescence intensity

One of the main problems we encounter when processing the results of experiments in Synthetic Biology are the units of measurement of fluorescence data. Unlike absorbance, where there is a simple conversion between Optical Density (OD) and cell number, there is no direct relationship between the Relative Units of Fluorescence (RFU) and the number of protein molecules in the cell. Moreover, RFUs vary among reporter fluoroproteins: for example, an RFU of the GFP protein does not have to be equivalent to an RFU of the mRFP protein, sfGFP, etc.

Thanks to initiatives such as the Interlab Study, we have been able to go a step further and obtain a MEFL/cellGFP factor of equivalence between the RFU of the GFP protein and the Molecules of Equivalent Fluorochrome (MEFL). This relationship is an important breakthrough, as it can give us a more accurate estimation of the amount of GFP molecules in the cell.

However, another reporter protein have been widely used in Printeria experiments, such as the sfGFP or YFP. In the case of sfGFP, these protein has a much faster folding than GFP, which translates into a higher fluorescence intensity per molecule. And that's really interesting in the field of experimentation. In the case of YFP, the Wet lab Printeria team has realized that very little is known about this reporter protein, so it has been proposed in this project to get as much information as possible about YFP and its variants (check Printeria Improve). But in both cases, the equivalence factor between fluorescence and equivalent molecules is unknown...

Therefore, in order to obtain the MEFL/cellsfGFP and MEFL/cellYFP factors, the Printeria Modeling and Lab teams have designed a comparative experiment between GFP and both reporter proteins. The experiment consists of designing two identical transcriptional units (TU), changing only the CDS sequence so that each TU will produce GFP and our protein reporter (sfGFP or YFP), respectively. It should be added that this experiment is based on two fundamental assumptions:

  1. The number of GFP molecules produced in the cells is equivalent to the number of MEFL.

  2. Given two TU with identical promoters, RBS and terminators, but with different CDS, under the same experimental conditions, the number of molecules produced by each TU is the same.

Taking these axioms into account, the materials and procedure followed to calculate the MEFL/cell factors were as follows.

Materials:

  • Measuring equipment: Biotek Cytation3

  • 96 well plate

  • MATLAB 2018a software

Procedure:

  1. From the fluorescein spectrum, and the fluorescence data obtained from the Interlab Study experiment, we apply medium, gain and efficiency corrections .

  2. The data are introduced in the Excel file of the Interlab Study. From the Fluorescein standard curve sheet we can obtain the MEFL/RFU factor, and then calculate the MEFL/cellGFP factor.

    Parameters

    Value

    Culture volume (96 well plate)

    200 μL

    Cells per μL per OD unit

    200 cells/OD μ L

    MEFL/RFU factor

    4,38.1010 MEFL/RFU

    MEFL/cellGFP factor

    273.7 MEFL OD/RFU cell

    MEFL/cell factor calculation

  3. We establish the protocol of the experiment and the parameters of our equipment. The experiment consists in the measurement of the absorbance and fluorescence of two TU with identical promoter, RBS and transcriptional terminator, but whose CDS codifies for GFP and our reporter protein. We have done two differente experiments with the same protocol, by using sfGFP TU and YFP TU. The most relevant information of the experiment is detailed in the following Table.

    Parameters

    Description

    Time

    06:00:00 (HH:MM:SS). Measurement interval: 05:00 (MM:SS)

    Number of samples

    8 samples for each TU. Total samples: 16

    Temperature

    37 ºC

    Shake

    Double Orbital Continuous

    Absorbance. Optical Density (OD)

    Wavelenght at 600 nm emission

    Excitacion wavelength

    485 nm

    Emission wavelength

    528 nm

    Gain

    60

    Experimental parameters

  4. The experiment is introduced into the equipment and the absorbance and fluorescence curves are obtained, as well as the curve of Fluorescence F/Absorbance OD or FOD ratio with the applied medium fluorescence correction.

  5. The absorbance and fluorescence data are exported to an Excel file.

  6. Running the MATLAB GFP_sfGFP_comparison.m and GFP_YFP_comparison.m script (for each experiment):

    1. We extract the FOD data from the GFP and sfGFP from the Excel file.

    2. We apply the gain and efficiency corrections of the spectrum to the FOD.

    3. We plot the FOD curves and look for a stationary equilibrium time interval in the expression of the GFP and sfGFP proteins. In our experiment, we have decided to chose the interval [145 - 290] min for sfGFP experiment and [40 - 350] min for YFP experiment.

    4. We obtain the average value of both regions.

    5. We calculate the number of GFP equivalent molecules or MEFL by multiplying the FOD data by the MEFL/cellGFP factor.

    6. If we assume that the number of molecules expressed by both TU in th experiment is the same, the number of MEFL for the calculated GFP is the same as the number of MEFL for the other reporter protein (sfGFP or YFP).

    7. We calculate the MEFL/cellsfGFP and MEFL/cellYFP factors by dividing the MEFL number by the average FOD value of the sfGFP and YFP in the stationary region, respectively.

Comparison between fluorescence intensity of GFP and sfGFP reporter proteins
Comparison between fluorescence intensity of GFP and YFP reporter proteins

Reporter protein

MEFL/cell factor (MEFL·OD/RFU·cell)

GFP

273.7

sfGFP

121.4

YFP

57.3

MEFL/cell factors calculated applying comparison protocol

With MEFL/cell factors, FOD data obtained in any experiment in which GFP, sfGFP or YFP are used as reporter proteins can be transformed into equivalent fluorescein molecules by applying the following ratio:

The new data give us a more accurate estimation of the number of molecules in the cell. Consequently, by relating the experimental results with the theoretical mathematical models in the optimization process, the parameters of the model acquire values more consistent with their physical significance, working in equivalent molecules and not in arbitrary units.