Difference between revisions of "Team:Marburg/Measurement"

Line 249: Line 249:
 
   </div>
 
   </div>
  
 +
</p>   
 +
    </div>
 +
  </div>
 
<div class="collapsible">
 
<div class="collapsible">
 
     <div class="btn_expand">Finding the best reporter</div>
 
     <div class="btn_expand">Finding the best reporter</div>

Revision as of 13:27, 15 October 2018

Measurement

Measure what is measurable, and make measurable what is not so.
-- Galileo Galilei

Highly characterized parts are an absolute prerequisite for synthetic biology to enable rational design of DNA constructs. While thousands of parts were analyzed for E. coli, no such data is available for V. natriegens making design of plasmids a guessing game. To tackle this foundational challenge for our chassis, we established a measurement and data analyzation workflow tailored to its unmatched growth rate. Initially, we carefully examined the plasmidal context yielding the highest dynamic range in reporter experiments and concluded superior performance when utilizing the lux operon and ColE1. Subsequently, we applied this protocol to obtain reproducible data for promoter strengths - including inducible promoters, - insulation by our connectors and expression influence of different oris. qPCR experiments provided additional insights into plasmid copy number dependent on reporter expression. We are certain that our data, in combination with our Marburg Collection, will foster the widespread utilization of V. natriegens in synthetic biology.
Establishing a workflow for platereader experiments

Experimental approach

Most of our data were obtained by measuring the expression of reporters in platereader experiments. In the first attempts, we failed to obtain reproducible data by applying workflows that are commonly used for E. coli. We realized that a new chassis requires overthinking existing procedures and we decided to establish a workflow for platereader experiments tailored to V. natriegens which respects species specific properties, primarily its unbeaten doubling time.

Many platereader workflows for E. coli start with growing overnight cultures of certain samples, measuring the OD600 and dilute all samples in a 96 well plate to a defined OD600 (e.g. 0.05). Depending on the number of samples, pipetting the test plate can easily take up to 45 minutes.
When first following this approach with V. natriegens, we realized that a different workflow is needed for the worlds fastest growing organism. We tested how much V. natriegens grows during the preparation of a full 96 well plate. We set up an experiment using a stationary culture of V. natriegens with a plasmid weakly expressing lux - to achieve realistic conditions - and diluted this culture 1 : 100 in a 96 well plate with one pipetting step taking 30 seconds. The result of this experiment can be seen in figure 1.
The data show an obvious trend towards higher OD for wells that were pipetted firstl. Seemingly, V. natriegens is able to recover from stationary phase and undergo almost one cell division in 45 minutes at room temperature. Please note that performing this experiment with a culture in the exponential phase, as described in some E. coli protocols, would most likely result in an even stronger trend.
With this in mind, we tried to establish a workflow that omits measuring and independently diluting individual wells. We tested to cultivate our precultures - inoculated from glycerol stocks - directly in 96 well plates and incubated this plate for five to six hours in a platereader or shaking incubator. For V. natriegens, this time frame is sufficient for all cultures to reliably reach stationary phase which equals an overnight culture for E. coli. The cultures are then diluted in two steps: 1:50 and 1:40, finally resulting in a 1:2000 dilution of the preculture. Compared to the commonly used workflows for E. coli, our approach does not consider the OD600 of individual wells but instead dilutes all cultures by the same factor.
The OD600 after 1:50 dilution of the 96 well plate is shown in figure 2. Despite not calculating dilutions for individual wells, the range of values is explicitly smaller and additionally no positional bias can be observed.
A
B
Figure 1:
Heterogeneity of 96 well plate after preparation

A) One pipetting step each 30 s, starting with A1
B) Intermediate dilution (1:50) of a preculture
Moreover, we realized that inoculating with a low cell number is advantageous when working with V. natriegens. This prolongs the exponential phase, the period in which most relevant data are acquired. A 1:2000 dilution results in a cell density much lower than the inoculum used in most E. coli experiments.The subsequent, kinetic measurement can be completed in as less as five to six hours.

Data analyisis

Besides the experimental workflow, we established an approach for fast and accurate data analysis. From a mathematical point of view, constant expression and constant degradation result in a steady state level of a molecule. In the context of bacterial reporter experiments, the molecule is a reporter protein or enzyme and the steady state level. That represents a constant signal to OD600 ratio, meaning a constant reporter concentration in the growing cells. For a stable reporter, constant degradation is actually due to dilution by cell division. Thus, the degradation rate mainly depends on the growth rate.
To conclude, we assumed that a constant signal to OD600 ratio is achieved throughout the exponential phase since the growth rate, as well as the expression from constitutive or constantly induced promoters remains stable.
With this in mind, we aimed to create an algorithm identifying the exponential growth phase and calculating the signal to OD600 ratio. In our first experiments we tried to identify a point in time at which all cultures grow exponentially, and failed. We were not able to obtain reproducible data for two reasons. Firstly, cultures grow differently, depending on the starting concentration and fitness differences caused by varying test constructs and expression strengths. Secondly, individual measurements are highly variable (we saw this especially for OD600 measurements). Therefore performing calculations with a single value is highly susceptible to outliers.
We solved both issues by developing a Matlab script that identifies the exponential phase and includes a range of seven measuring points for each individual well. The culture is assumed to be in the mid exponential phase at an OD600 of 0.2. Three timepoints (5 min intervals), each before and after the culture has first reached 0.2, are taken. Then the mean of all signal to OD600 ratios is calculated. Through this calculation, a single value is assigned to each well representing the strength of reporter expression in the exponential phase. All samples were measured in four technical replicates in three subsequent independent experiments.
Consequently, every result (e.g. promoter strength) is, in total, the mean of 84 measurements. This high number of raw data leads to a high degree of reproducibility and, as we believe, to highly accurate characterization data.

Example Matlab code

clear all
close all
%% Import Platereader raw data
Lux_Data_raw_Day1 = xlsread('Connector_Lux_071018.xlsx','All Cycles');
OD_Data_raw_Day1 = xlsread('Connector_OD_071018.xlsx','All Cycles');

Lux_Data_raw_Day2 = xlsread('Connector_Lux_071018_2.xlsx','All Cycles');
OD_Data_raw_Day2 = xlsread('Connector_OD_071018_2.xlsx','All Cycles');

Lux_Data_raw_Day3 = xlsread('Connector_Lux_081018.xlsx','All Cycles');
OD_Data_raw_Day3 = xlsread('Connector_OD_081018.xlsx','All Cycles');

%% Merge all data in two matrices
OD_Data(:,:,1) = OD_Data_raw_Day1;
OD_Data(:,:,2) = OD_Data_raw_Day2;
OD_Data(:,:,3) = OD_Data_raw_Day3;

Lux_Data(:,:,1) = Lux_Data_raw_Day1;
Lux_Data(:,:,2) = Lux_Data_raw_Day2;
Lux_Data(:,:,3) = Lux_Data_raw_Day3;

%% Blank substraction and cut off
for h = 1:size(Lux_Data,3)
for k = 1:size(Lux_Data,2)
        Blank = mean(Lux_Data([60,72,84,96],k,h));
    for j = 1:size(Lux_Data,1)
        Lux_Data(j,k,h) = Lux_Data(j,k,h)-Blank;
        if Lux_Data(j,k,h) < 50
           Lux_Data(j,k,h) = 50; % Cut off for Lux signal
        end
    end
end
end

for h = 1:size(OD_Data,3)
for k = 1:size(OD_Data,2)
        Blank = mean(OD_Data([60,72,84,96],k,h));
    for j = 1:size(OD_Data,1)
        OD_Data(j,k,h) = OD_Data(j,k,h)-Blank;
        if OD_Data(j,k,h) < 0.01
           OD_Data(j,k,h) = 0.01; % Cut off for OD
        end
    end
end
end

%% Calculating ratio around OD 0.2

Ratios = zeros(size(OD_Data,1),1,3);
for q = 1:size(OD_Data,3) % looping over days
for o = 1:size(OD_Data,1) % looping over samples
    for p = 1:size(OD_Data,2)-3 % looping through time points
        if OD_Data(o,p,q) > 0.2 && OD_Data(o,p+1,q) > 0.2 && Ratios(o,q) == 0
           Ratios(o,q) = mean(Lux_Data(o,p-3:p+3,q)./OD_Data(o,p-3:p+3,q));
        end
    end
end
end

%% Calculating mean and std of individial samples

for k = 1:12
Samples(k,1,1:3) = mean(Ratios([k,k+12,k+24,k+36],:)); % calculate mean of technical triplicates
Samples(k,2,1:3) = std(Ratios([k,k+12,k+24,k+36],:)); % calculate std of technical triplicates
end

for k = 13:24
Samples(k,1,1:3) = mean(Ratios([k+36,k+48,k+60,k+72],:)); % calculate mean of technical triplicates
Samples(k,2,1:3) = std(Ratios([k+36,k+48,k+60,k+72],:)); % calculate std of technical triplicates
end

%% Sort samples for top and bottom row

Names = {'J23100', '5Con1 long','5Con2 long','5Con3 long','5Con4 long',...
        '5Con5 long','5Con1 short','5Con2 short','5Con3 short',...
        '5Con4 short','5Con5 short','5Con1 long','5Con2 long','5Con3 long',...
        '5Con4 long','5Con5 long','5Con1 short','5Con2 short','5Con3 short',...
        '5Con4 short','5Con5 short', 'Promoter Dummy'};
Top_row = Samples(1:11,:,:); 
Bot_row = Samples(13:23,:,:);

SortedValues = [];
for k = 1:size(Top_row,1)
SortedValues = [SortedValues; Top_row(k,:,:); Bot_row(k,:,:)];
end
SortedValues = [SortedValues;Samples(12,:,:)];
SortedValues(22,:,:) = []; 

%% Calculate relativ strength

Relative_strength = SortedValues;
for h = 1:size(SortedValues,3)
for k = 1:size(SortedValues,1)
    Relative_strength(size(SortedValues,1)-k+1,2,h) = ...
        Relative_strength(size(SortedValues,1)-k+1,2,h)/Relative_strength(1,1,h);
    Relative_strength(size(SortedValues,1)-k+1,1,h) = ...
        Relative_strength(size(SortedValues,1)-k+1,1,h)/Relative_strength(1,1,h);
end
end

%% plot relative strenths

figure(1) % constructs with J23100 
hold on
bar(mean(Relative_strength([1:11,22],1,1:3),3),'facecolor',[125/255,202/255,97/255])
errorbar((mean(Relative_strength([1:11,22],1,1:3),3)),...
    std(Relative_strength([1:11,22],1,1:3),1,3),'linestyle','none','color','k')
set(gca, 'YScale', 'log')
ylabel('normalized Luminescence/OD_6_0_0')
set(gca,'Color','w')
xticks([1:12])
xticklabels(Names([1:11,22]))
xtickangle(45)
ylim([0.001 3])
yticks([0.001,0.01,0.05, 0.1, 0.5, 1.0, 2.0 ])
yticklabels([0.001,0.01,0.05, 0.1, 0.5, 1.0, 2.0])

figure(2) % constructs with promoter dummy 
hold on
bar(mean(Relative_strength([1,12:22],1,1:3),3),'facecolor',[125/255,202/255,97/255])
errorbar((mean(Relative_strength([1,12:22],1,1:3),3)),...
    std(Relative_strength([1,12:22],1,1:3),1,3),'linestyle','none','color','k')
set(gca, 'YScale', 'log')
ylabel('normalized Luminescence/OD_6_0_0')
set(gca,'Color','w')
xticks([1:12])
xticklabels(Names([1,12:22]))
xtickangle(45)
ylim([0.001 3])
yticks([0.001,0.01,0.05, 0.1, 0.5, 1.0, 2.0 ])
yticklabels([0.001,0.01,0.05, 0.1, 0.5, 1.0, 2.0])

Finding the best reporter

Figure 4: Mean ratio of reporter signal over medium blank during the coarse of the experiment.
After having established a reliable workflow for V. natriegens, we investigated three different reporters and measured the signal to blank ratio. Test constructs (shown in figure xxxxx) were built by using the same set of parts except for the coding sequence. sfGFP, RFP, YFP and the lux operon were analyzed for their performance in V. natriegens. The best signal to blank ratio by far was achieved for the lux operon (2000), followed by sfGFP (3), RFP (1) and YFP (no detectable signal). The main explanation for the superior performance of the lux operon is the almost complete absence of background signal without reporter expression. This makes the lux operon a perfect reporter that can even be used to analyze extremely low levels of expression caused by very weak promoters or terminator readthrough. Based on this finding, we decided to use the lux operon as our reporter for all subsequent experiments.

A
B
C
D
Figure 2: Test constructs for reporter experiment
Plasmids were built with four different reporters.
A) Lux B) RFP C) sfGFP D) YFP
In contrast to fluorescence reporters, the enzymes expressed from the lux operon lead to continuous emission of light. This can result in enhanced crosstalk between neighboring wells. The extent of crosstalk highly depends on the type of 96 well plate that is used in the experiment. We analyzed the crosstalk in clear and black 96 well plates by placing a single lux expressing sample in well C3 and filled all remaining wells with medium. As can be seen in figure xxxx, the signal from a single well is sufficient to significantly illuminate a huge portion of the clear plate (~ 1 % signal overflow to neighboring wells) while the crosstalk is reduced tenfold when using a black plate (~ 0.1 % signal overflow to neighboring wells).
A
B
Figure 3: Luminescence pattern in clear (A) and black (B) 96 well plate
200 µL of one Lux expressing sample was placed in C3 while all other wells were filled with medium
Thus, we used black plates and payed attention not to place the brightest cultures in direct proximity to the darkest cultures. Therefore we do not see crosstalk as a decisive argument against the lux operon. However, algorithms are under development that will allow for a mathematical correction to further improve the performance of the lux operon as reporter (Georg und seine Leute unpublished)

Finding the best ori

Figure 3: Testing the Lux expression from plasmids with different oris
Data were normalized over the strongest construct ColE1. Error bars represent the standard deviation of the measurements of three independent experiments
The dynamic range of a reporter experiment does not only depend on the used reporter but also on the copy number of the tested plasmids, which is determined by the used origin of replication. We wanted to identify the ori which yields the highest dynamic range when expressing the lux operon. To do that, we constructed three plasmids expressing lux. All parts, except for the ori, were identical and tested them for signal strength. We obtained the highest expression from the construct harbouring the ColE1 ori, followed by p15A and pMB1 (figure xxxx). We suggest that ColE1 yields plasmids with the highest copy number. We performed qPCR experiments that that support this hypothesis. We observed a qualitative correlation between copy number and expression strength. As a high dynamic range is essential for analyzing weak expression levels, we chose ColE1 as our default ori for all subsequent experiments.

B. Marchal