Interlab

IGEM is an international Synthetic Biology competition, which aims to set up standard protocols that work in any laboratory on the planet. To manage this task, Interlab Study was created, inviting all teams to participate by performing the same experiment: making measures of the Green Fluorescent Protein (GFP) to determine the feasible cell population.

In order to determine cell population, scientists usually use spectrophotometry to measure cells culture absorbance in 600 nm, and through it, the optical density (OD) can be obtained. So, theoretically, the higher cells number the higher OD. However, the values of OD obtained are under high variability, because of different calibration and precision between labs equipment, different glassware size, and others lab-to-lab factors. In addition, through this methodology, it isn’t possible to separate dead feasible cells.

In this sense, to respond to all the problems above, the methodology of measuring GFP is another way to determine feasible cells, once the dead ones will not express GFP. Through the GFP measurement methodology, the Measurement Committee wants our help to answer the following question:

‘’Can we reduce lab-to-lab variability in fluorescence measurements by normalizing to absolute cell count or colony-forming units (CFUs) instead of OD?‘’

In order to achieve this goal, Team USP-EEL-Brazil followed the Interlab protocols and sent the results to iGEM's measurement committee.

Materials and Methods

In order to make the experiments, we followed the method in the link below: (colocar o link)

The plasmids used are available in the iGEM kit:

Device                 Part Number Plate           Location

Negative control  BBa_R0040 Kit Plate 7   Well 2D

Positive control   BBa_I20270 Kit Plate 7   Well 2B

Test Device 1      BBa_J364000 Kit Plate 7   Well 2F

Test Device 2      BBa_J364001 Kit Plate 7   Well 2H

Test Device 3      BBa_J364002 Kit Plate 7   Well 2J

Test Device 4      BBa_J364007 Kit Plate 7   Well 2L

Test Device 5      BBa_J364008 Kit Plate 7   Well 2N

Test Device 6      BBa_J364009 Kit Plate 7   Well 2P

Equipment used for measurements: TECAN INFINITY M200 PRO Plate used for measurements: Corning® Costar Clear Polystyrene 96-Well Plates

Results

Go to top