Difference between revisions of "Team:ZJU-China/Safety"

Line 170: Line 170:
 
}
 
}
 
@media only screen and (max-width:990px){
 
@media only screen and (max-width:990px){
 +
.igem_content_wrapper {
 +
    width: 200% !important;
 +
}
 +
 +
.igem_2018_team_content {
 +
width: 200% !important;
 +
}
 +
 +
.cnt {
 +
margin-left: -3em !important;
 +
}
 +
 +
.tl {
 +
margin-left:-2em !important;
 +
}
 +
 +
.tl:after {
 +
margin-left:0 !important;
 +
}
 +
 +
.nav-toggle {
 +
float: right !important;
 +
}
 
nav.navbar.bootsnav ul.nav > li.dropdown > a.dropdown-toggle:after,
 
nav.navbar.bootsnav ul.nav > li.dropdown > a.dropdown-toggle:after,
 
nav.navbar.bootsnav ul.nav > li.dropdown.on > a.dropdown-toggle:after{ content: " "; }
 
nav.navbar.bootsnav ul.nav > li.dropdown.on > a.dropdown-toggle:after{ content: " "; }

Revision as of 07:38, 16 October 2018

Improve Part
SAFETY 

Our project aims to detect the injury based on a cell-free device with three connected enzymes which fixed on a biofilm scaffold. We use blood specimens with biochemical analysis to calibrate our device and help us with our machine learning modeling to set a diagnosis criterion.



Project Safety Biofilm Scaffold

Our biofilm scaffold consists of curli which is the protein found on the surface of E.Coli. Curli may facilitate bacteria’s invasion into host cells and activate corresponding cytokines and inflammatory mediators in plasma. But the system we wish to produce will be ultimately cell-free and no living organisms will be included. Besides, curli will be immobilized and covered by Nafion on the electrode, so contact with curli will not happen. Therefore, biofilm scaffold is relatively safe.

Blood Samples

We have gotten approval from our university authority and collected some blood samples from SIR RUN RUN SHAW HOSPITAL, which is classified as a Grade 3 Class A hospital by Chinese government. The procedure of blood sampling was done by medical personnel using ideal blood collection equipment. Besides, our experiment was conducted under professional doctors' supervision and waste was collected by the specialties in the hospital. (It is also an essential part of Integrated Human Practice.)


Our project meets ethical requirements. Blood samples we got from hospital are all remaining samples after satisfying patients’ pathological diagnosis need. We keep secret of patients’ privacy information. We conduct experiments with clinical material following our country's laws and our university's rules.


The main issue for work with blood samples is the potential for infection. Clinical samples may be contaminated with pathogens. The high risk, well known viral agents such as Human Immunodeficiency Virus (HIV), Hepatitis B virus (HBV) and Hepatitis C Virus (HCV) are not the only agents that may be present in blood. Other viruses such as HTLV1 and B19 as well as various bacterial agents may also be present. Regarding the likely incidence of a pathogen in blood samples, several factors should be considered. These include known medical history of a patient or donor, whether the samples are from individuals showing clinical symptoms of infectious disease, the incidence of the various pathogens that are endemic in the local population or donor group and the type of sample. Fortunately, SIR RUN RUN SHAW HOSPITAL offered us the physiological indices of blood samples and other relevant information. So, the samples we used are from formal approach and relatively less dangerous. To minimize the risks,we have made Standard Operating Procedure (SOP) which is strictly followed in our iGEM lab.

Standard Operating Procedure (SOP)

As insurance, Blood samples from all patients should be considered infective. The following precautions followed in our lab are also recommended for all health-care workers in clinical laboratories.

1. All the experiments where blood is involved must be conducted in a separate room within the laboratory.

2. All specimens of blood should be put in a well- constructed container with a secure lid to prevent leaking. Care should be taken when dealing with each specimen to avoid contaminating the outside of the container and of the laboratory form accompanying the specimen.

3. Lab surface including correlated equipment is decontaminated with chemical disinfectant prior and after disposal.

4. Every piece of material that has been in direct contact with blood should be disposed of correctly via the clinical waste route when work activities are completed.

5. All persons processing blood specimens should wear gloves. Gloves should be changed, and hands washed after completion of specimen processing.

6. Use of sharp objects (e.g. needles, syringes, scissors) should be limited for fear of injuries and cross infection.

7. All persons should wash their hands after completing blood specimens’ processing.

General Safety

Working with living modified organisms is always a risk. All standard precautions must be taken. Before starting to work in the lab, every member of our team was asked to attend laboratory safety lesson and take an biosafety examination.

Wearing

Everyone wears protective lab coats, enclosed leather shoes, gloves and safety glasses before laboratory activities.

Fig.1 Working with the Clean Bench
Storage

The chemical and biological reagents are stored in the proper place and suitable temperature. Hazardous or corrosive chemicals are stored separately.

Fig.2 Storage for chemical and biological reagents
Waste

Waste should be classified and disposed of separately.

Safety Apparatus

Our iGEM lab is equipped with safety apparatus such as fire extinguishers, emergency showers, eyewash stations, and first aid kits in case of dire situations.

Fig.3 The fire extinguisher
Fig.4 The fire blanket
Fig.5 The emergency shower
Fig.6 The eyewash equipment
Fig.7 The first-aid case
References

[1] Michelle M. Barnhart Matthew R. Chapman. Curli Biogenesis and Function. Annual Review of Microbiology(2006):131-147

[2] CDC.Recommendations for Prevention of HIV Transmission in Health-Care Settings.MMWR,1987;36

[3] Z Botyanszki, PKR Tay, PQ Nguyen, MG Nussbaumer, NS Joshi.Engineered catalytic biofilms: Site-specific enzyme immobilization onto E. coli curli nanofibers. Biotechnology & Bioengineering, 2015, 112 (10) :2016-2024