Difference between revisions of "Team:HBUT-China/Safety"

(Prototype team page)
 
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{HBUT-China}}
+
{{ HBUT-China/templates/head }}
 
<html>
 
<html>
 +
 
  
 +
    <section class="section"></section>
  
<div class="column full_size">
+
      <section class="section">
  
<h1> Safety </h1>
+
       
<p>Please visit the <a href="https://2018.igem.org/Safety">Safety Hub</a> to find this year's safety requirements & deadlines, and to learn about safe & responsible research in iGEM.</p>
+
        <div class="container" >
 +
            <center>
 +
                <h1 style="font-size:350%;">
 +
                    Safety
 +
                </h1>
 +
                <!-- <p class="subtitle">
 +
                        Wuhan China
 +
                     
 +
                    </p> -->
 +
            </center>
 +
            <p class="subtitle">
  
<p>On this page of your wiki, you should write about how you are addressing any safety issues in your project. The wiki is a place where you can <strong>go beyond the questions on the safety forms</strong>, and write about whatever safety topics are most interesting in your project. (You do not need to copy your safety forms onto this wiki page.)</p>
+
            </p>
 +
            <div class="content " style="width:80%;margin-left: auto;margin-right: auto;">
 +
                    <center>
 +
                    <p class="subtitle" style="margin-left: auto;margin-right: auto;">
 +
                            Overview
 +
                    </p>
 +
                    <p> </p>
 +
                    </center>
 +
                    <article class="message">
 +
                        <div class="message-body">
 +
                            <p style="text-justify: inter-ideograph;text-align: justify;">This year, team HBUT-China build up a system in E. coli which can detect nickel ions in the environment, using the methods of synthetic biology. Even if the chassis organism we used were barely E. coli DH5alpha, which are classified into Risk Group 1, it was also necessary for our team members who were in charge of the wet-lab experiments to receive lab safety training. Our PI, Dr.Dai Jun and Dr.Liu Zhijie, who are experienced and scrupulous, offered us training on experimental skills and lab safety. Here we want to share our experiences on lab safety control.</p>
 +
                        </div>
 +
                    </article>
  
</div>
+
                    <center>
 +
                    <p class="subtitle" style="margin-left: auto;margin-right: auto;">
 +
                            1. General Safety Training
 +
                    </p>
 +
                    </center>
 +
                    <div class="content" style="text-justify: inter-ideograph;text-align: justify;">
 +
                        <p> </p>
 +
                        <p style="margin-left: auto;margin-right: auto;">
 +
                                Before we started our experiments, all of our team members responsible for the wet-lab experiments received detailed and rigid training on biosafety and lab safety from Dai and Liu. The training included standard experimental procedures, usage of biosafety cabinets and normative disposal of experimental waste etc. During the first few weeks since we started our experiments, Dr.Liu stayed with us all the way in the lab to supervise our manipulations. He gave us guidance and enlightened us when necessary. During our time in lab, we kept thorough lab records, including protocols, consideration on error-prone steps and careful discussions etc. None of us conducted experiments on our own until it could pass a check on lab safety and experimental operations.
 +
                        </p>
 +
                    </div>
  
 +
                    <center>
 +
                    <p class="subtitle" style="margin-left: auto;margin-right: auto;">
 +
                            2. Chassis Organism Safety
 +
                    </p>
 +
                    </center>
 +
                    <div class="content" style="text-justify: inter-ideograph;text-align: justify;">
 +
                        <p> </p>
 +
                        <p style="margin-left: auto;margin-right: auto;">
 +
                                The chassis organisms used in our project is E. coli DH5alpha, which is classified into Risk Group 1 and Safety Level 1. Because of this, It does not cause disease in healthy adult humans and is allowed to be operated in open bench. Our genetically modified bacteria were cautiously operated and discarded and surly not released to the natural environment to prevent interference to the natural environment.
 +
                        </p>
 +
                    </div>
  
<div class="column two_thirds_size">
+
                    <center>
<h3>Safe Project Design</h3>
+
                    <p class="subtitle" style="margin-left: auto;margin-right: auto;">
 +
                            3. Experiment Safety
 +
                    </p>
 +
                    </center>
 +
                    <div class="content" style="text-justify: inter-ideograph;text-align: justify;">
 +
                        <p> </p>
 +
                        <p style="margin-left: auto;margin-right: auto;">
 +
                                In order to minimize potentially risks that could be brought about by certain instruments and reagents, our members were requested to use normative protective equipment and follow the safety manuals throughout our lab time. Instruments like alcohol burner and centrifugal machine were carefully used according to the safety manuals. Gloves, lab coats, pants and close-toed shoes are demanded during lab time, and it is not allowed to touch about when wearing gloves. Besides, no food or drink is allowed in the working space.
 +
                        </p>
 +
                        <p> </p>
 +
                        <div class="columns">
 +
                            <div class="column">
 +
                                <img src="https://static.igem.org/mediawiki/2018/3/3e/T--HBUT-China--safety1.jpg" alt="">
 +
                            </div>
 +
                            <div class="column">
 +
                                <img src="https://static.igem.org/mediawiki/2018/2/20/T--HBUT-China--safety2.jpg" alt="">
 +
                            </div>
 +
                            <div class="column">
 +
                                <img src="https://static.igem.org/mediawiki/2018/7/74/T--HBUT-China--safety3.jpg" alt="">
 +
                            </div>
 +
                        </div>
 +
                    </div>
 +
            </div>
  
<p>Does your project include any safety features? Have you made certain decisions about the design to reduce risks? Write about them here! For example:</p>
 
  
<ul>
+
        </div>
<li>Choosing a non-pathogenic chassis</li>
+
    </section>
<li>Choosing parts that will not harm humans / animals / plants</li>
+
<li>Substituting safer materials for dangerous materials in a proof-of-concept experiment</li>
+
<li>Including an "induced lethality" or "kill-switch" device</li>
+
</ul>
+
  
</div>
 
  
<div class="column third_size">
+
</html>
<h3>Safe Lab Work</h3>
+
{{ HBUT-China/templates/footer }}
 
+
<p>What safety procedures do you use every day in the lab? Did you perform any unusual experiments, or face any unusual safety issues? Write about them here!</p>
+
 
+
 
+
<h3>Safe Shipment</h3>
+
 
+
<p>Did you face any safety problems in sending your DNA parts to the Registry? How did you solve those problems?</p>
+
</div>
+
 
+
 
+
</html>
+

Latest revision as of 01:37, 8 October 2018

Safety

Overview

This year, team HBUT-China build up a system in E. coli which can detect nickel ions in the environment, using the methods of synthetic biology. Even if the chassis organism we used were barely E. coli DH5alpha, which are classified into Risk Group 1, it was also necessary for our team members who were in charge of the wet-lab experiments to receive lab safety training. Our PI, Dr.Dai Jun and Dr.Liu Zhijie, who are experienced and scrupulous, offered us training on experimental skills and lab safety. Here we want to share our experiences on lab safety control.

1. General Safety Training

Before we started our experiments, all of our team members responsible for the wet-lab experiments received detailed and rigid training on biosafety and lab safety from Dai and Liu. The training included standard experimental procedures, usage of biosafety cabinets and normative disposal of experimental waste etc. During the first few weeks since we started our experiments, Dr.Liu stayed with us all the way in the lab to supervise our manipulations. He gave us guidance and enlightened us when necessary. During our time in lab, we kept thorough lab records, including protocols, consideration on error-prone steps and careful discussions etc. None of us conducted experiments on our own until it could pass a check on lab safety and experimental operations.

2. Chassis Organism Safety

The chassis organisms used in our project is E. coli DH5alpha, which is classified into Risk Group 1 and Safety Level 1. Because of this, It does not cause disease in healthy adult humans and is allowed to be operated in open bench. Our genetically modified bacteria were cautiously operated and discarded and surly not released to the natural environment to prevent interference to the natural environment.

3. Experiment Safety

In order to minimize potentially risks that could be brought about by certain instruments and reagents, our members were requested to use normative protective equipment and follow the safety manuals throughout our lab time. Instruments like alcohol burner and centrifugal machine were carefully used according to the safety manuals. Gloves, lab coats, pants and close-toed shoes are demanded during lab time, and it is not allowed to touch about when wearing gloves. Besides, no food or drink is allowed in the working space.