Difference between revisions of "Team:ZJU-China/Safety"

Line 388: Line 388:
 
<h5>Fig.2 Dilution of fluorescein <sup style="font-family: .8em;">[1]</sup></h5>
 
<h5>Fig.2 Dilution of fluorescein <sup style="font-family: .8em;">[1]</sup></h5>
 
<p style="padding-left: 1em;"></br>Measure the plate in plate reader, the excitation filter was set to 485nm/10nm and the emission filter was set to 525nm/10nm. Pathlength correction was turned off. The gain setting was 50. Fluorescence was from the top. The temperature setting was 26.6&deg;C. Record the data.</p>
 
<p style="padding-left: 1em;"></br>Measure the plate in plate reader, the excitation filter was set to 485nm/10nm and the emission filter was set to 525nm/10nm. Pathlength correction was turned off. The gain setting was 50. Fluorescence was from the top. The temperature setting was 26.6&deg;C. Record the data.</p>
<span class="psg_subtitle">Cell measurement</span>
+
<p style="padding-left: 1em;">Make a 1:10 dilution of of the overnight cultures prepared after colony selection in LB medium + Chloramphenicol and measure Abs 600 of these 1:10 diluted cultures. Then dilute the cultures further to a target Abs600 of 0.02 in a final volume of 12 ml LB medium + Chloramphenicol in 50 mL falcon tube (amber or covered with foil to block light). Incubate the cultures at 37&deg;C and 220 rpm. Take 500 µL samples of the cultures from each of the 8 devices, two colonies per device, at 0 and 6 hours of incubation and add them into 96 well plates as shown below. Place samples on ice before measurements.</p>
+
<h5>Fig.3 Loading samples <sup style="font-family: .8em;">[1]</sup></h5>
+
<p style="padding-left: 1em;"></br>Measure the samples (Abs 600 and fluorescence measurement). The cell measurement was under the same condition with the particle standard curve and the fluorescence standard curve, using the same plate.</p>
+
<span class="psg_subtitle">Counting colony-forming units (CFUs)</span>
+
<p>Measure the OD600 of cell cultures, making sure to dilute to the linear detection range of the plate reader. Then dilute the overnight culture to OD600 = 0.1 in 1 mL of LB + Cam media. Do this in triplicate for each culture and check the OD600 to make sure it is 0.1.</p>
+
<p></br>Do the following serial dilutions as blow.</p>
+
<h5>Fig.4 Dilutions <sup style="font-family: .8em;">[1]</sup></h5>
+
<p></br>Count the colonies on each plate with fewer than 300 colonies. And multiple the colony count by the final dilution factor on each plate to get the colony forming units (CFU) per 1mL of an OD600 = 0.1 culture.</p>
+
 
 
 
<span class="psg_ttl">Results</span>
 
<span class="psg_ttl">Results</span>

Revision as of 12:48, 13 October 2018

Improve Part
SAFETY 

Our project aims to detect the injury based on a cell-free device with three connected enzymes which fixed on a biofilm scaffold. We use blood specimens with biochemical analysis to calibrate our device and help us with our machine learning modeling to set a diagnosis criterion.



Project Safety Biofilm Scaffold

Our biofilm scaffold consists of curli which is the protein found on the surface of E.Coli. Curli may facilitate bacteria’s invasion into host cells and activate corresponding cytokines and inflammatory mediators in plasma. But the system we wish to produce will be ultimately cell-free and no living organisms will be included. Besides, curli will be immobilized and covered by Nafion on the electrode, so contact with curli will not happen. Therefore, biofilm scaffold is relatively safe.

Blood Samples

We have gotten approval from our university authority and collected some blood samples from SIR RUN RUN SHAW HOSPITAL, which is classified as a Grade 3 Class A hospital by Chinese government. The procedure of blood sampling was done by medical personnel using ideal blood collection equipment. Besides, our experiment was conducted under professional doctors' supervision and waste was collected by the specialties in the hospital. (It is also an essential part of Integrated Human Practice.)


Our project meets ethical requirements. Blood samples we got from hospital are all remaining samples after satisfying patients’ pathological diagnosis need. We keep secret of patients’ privacy information. We conduct experiments with clinical material following our country's laws and our university's rules.


The main issue for work with blood samples is the potential for infection. Clinical samples may be contaminated with pathogens. The high risk, well known viral agents such as Human Immunodeficiency Virus (HIV), Hepatitis B virus (HBV) and Hepatitis C Virus (HCV) are not the only agents that may be present in blood. Other viruses such as HTLV1 and B19 as well as various bacterial agents may also be present. Regarding the likely incidence of a pathogen in blood samples, several factors should be considered. These include known medical history of a patient or donor, whether the samples are from individuals showing clinical symptoms of infectious disease, the incidence of the various pathogens that are endemic in the local population or donor group and the type of sample. Fortunately, SIR RUN RUN SHAW HOSPITAL offered us the physiological indices of blood samples and other relevant information. So, the samples we used are from formal approach and relatively less dangerous. To minimize the risks,we have made Standard Operating Procedure (SOP) which is strictly followed in our iGEM lab.

Standard Operating Procedure (SOP)

As insurance, Blood samples from all patients should be considered infective. The following precautions followed in our lab are also recommended for all health-care workers in clinical laboratories.


• OD600 Reference Point


Add 100 µl LUDOX into wells A1, B1, C1, D1 and 100 µl of H2O into wells A2, B2, C2, D2. Then measure absorbance at 600 nm of all samples in all standard measurement modes in instrument and turn off the pathlength correction at the same time. The temperature setting was 26.6°C. Record the data.


• Particle Standard Curve


Obtain the tube labeled “Silica Beads“ from the InterLab test kit and vortex vigorously for 30 seconds. Then immediately pipet 96 µL microspheres into a 1.5 mL eppendorf tube. Add 904 µL of ddH2O to the microspheres and vortex well.


Prepare the serial dilution of microspheres as shown below. Set 4 copies.

Fig.1 Dilution of microspheres [1]


Measure the plate in plate reader, the excitation filter was set to 485nm/10nm and the emission filter was set to 525nm/10nm. Pathlength correction was turned off. The gain setting was 50. Fluorescence was from the top. The temperature setting was 26.6°C. Record the data.


• Fluorescence standard curve


Spin down fluorescein stock tube. Prepare 10x fluorescein stock solution (100 µM) by resuspending fluorescein in 1 mL of 1xPBS. Dilute the 10x fluorescein stock solution with 1xPBS to make a 1x fluorescein solution with concentration 10 μM.


Prepare the serial dilutions of fluorescein as shown below. Set 4 copies.

Fig.2 Dilution of fluorescein [1]


Measure the plate in plate reader, the excitation filter was set to 485nm/10nm and the emission filter was set to 525nm/10nm. Pathlength correction was turned off. The gain setting was 50. Fluorescence was from the top. The temperature setting was 26.6°C. Record the data.

Results OD600 Reference point
Tab.1 OD600 reference point
Particle Standard Curve
Fig.5 Particle standard curve 1 | Fig.6 Particle standard curve 2
Fluorescence standard curve
Fig.7 Fluorescence standard curve 1 | Fig.8 Fluorescence standard curve 2
Cell measurement
Tab.2 Raw plate reader measurements of fluorescence raw at 0 Hour
Tab.3 Raw plate reader measurements of fluorescence raw at 6 Hour
Tab.4 Raw data of Abs600 measurement at 0 hour
Tab.5 Raw data of Abs600 measurement at 6 hour


The results of the CFUs and the flow cytometry data have been submitted in time by online forms and a zip file.

Discussion


Our experiments have got a great result, showing that the protocol is rather detailed and easy to operate. We are pleased to share our data with other teams around the world and we sincerely hope the Interlab study this year goes well.

References

[1] https://static.igem.org/mediawiki/2018/0/09/2018_InterLab_Plate_Reader_Protocol.pdf

[2] https://2018.igem.org/Measurement/InterLab

[3] https://2018.igem.org/Measurement/InterLab/Plate_Reader

[4] https://2018.igem.org/Measurement/InterLab/Flow_Cytometry

Part Number Relative Strength
BBa_R0085(wild type) 1
BBa_K2721000 20.99
BBa_K2721001 17.75
BBa_K2721002 7.63
BBa_K2721003 13.92