Difference between revisions of "Team:Uppsala/Worm Culturing/Experiment"

Line 342: Line 342:
 
<p>Since small strongyles can be present in horses without large strongyles, but the opposite doesn’t occur, a system to separate the two types of strongyles was needed. The only pre-existing system employed by researchers that intend to collect nematodes of a certain class is the use of a pick under a microscope. This however is very time consuming and doesn’t allow obtaining a high concentration of nematodes and therefore a different procedure was needed. With this goal a microfluidic chip has been created. <p>
 
<p>Since small strongyles can be present in horses without large strongyles, but the opposite doesn’t occur, a system to separate the two types of strongyles was needed. The only pre-existing system employed by researchers that intend to collect nematodes of a certain class is the use of a pick under a microscope. This however is very time consuming and doesn’t allow obtaining a high concentration of nematodes and therefore a different procedure was needed. With this goal a microfluidic chip has been created. <p>
  
 
+
<br><img src="https://static.igem.org/mediawiki/2018/8/80/T--Uppsala--separator.png" height="70%" width="70%"> <p>
 +
<p><b>Figure 4:</b> shows the result from a sterilization test. The aliquote that was put into the rightmost flask proved to be sterile<br>
 
<p>The chip presented a single channel that splits in 2. The solution containing both types of nematodes, and any kind of contaminant, can be pumped inside the single channel. 2 valves, connected to the 2 split channels, can be used to redirect the flow from the main channel to one of the 2. Positioning this chip under a microscope, and analysing a strongyle when reaching the bifurcation allows the determination of the nature of the nematode. The flow is then directed towards the collection tubes. <p>
 
<p>The chip presented a single channel that splits in 2. The solution containing both types of nematodes, and any kind of contaminant, can be pumped inside the single channel. 2 valves, connected to the 2 split channels, can be used to redirect the flow from the main channel to one of the 2. Positioning this chip under a microscope, and analysing a strongyle when reaching the bifurcation allows the determination of the nature of the nematode. The flow is then directed towards the collection tubes. <p>
 
<p>This system, even though it doesn’t allow an immediate separation of all the large strongyles from the sample, leads to a quicker separation compared to hand picking. A low flow pump, such as a pressure or a syringe pump, is required. These details are described in the protocol we developed.<br>
 
<p>This system, even though it doesn’t allow an immediate separation of all the large strongyles from the sample, leads to a quicker separation compared to hand picking. A low flow pump, such as a pressure or a syringe pump, is required. These details are described in the protocol we developed.<br>

Revision as of 15:38, 15 October 2018