Difference between revisions of "Team:Uppsala/Transcriptomics/cDNA Conversion"

 
(11 intermediate revisions by 5 users not shown)
Line 35: Line 35:
  
  
<div class="svg-wrapper">
+
<div class="svg-wrapper" id="Project_Description">
  
  
Line 193: Line 193:
 
             <div id="toctitle"></div>
 
             <div id="toctitle"></div>
 
             <ul>
 
             <ul>
                 <li class="toclevel tocsection"><a href="#Project_Description" class="scroll"> <span id="whereYouAre"> Project Description  </span> </a>
+
                 <li class="toclevel tocsection"><a href="#Project_Description" class="scroll"> <span id="whereYouAre"> Transcriptomics</span> </a>
 
                         <ul>
 
                         <ul>
                             <li class="toclevel nav-item active"><a href="#top" class="nav-link scroll"> Overview </a></li>
+
                             <li class="toclevel nav-item active"><a href="#top" class="nav-link scroll"> cDNA Conversion</a></li>
                             <li class="toclevel nav-item"><a href="#Problem" class="nav-link scroll">  Problem  </a></li>
+
                             <li class="toclevel nav-item"><a href="#Exp" class="nav-link scroll">  Experiment</a></li>
                             <li class="toclevel nav-item"><a href="#Solution" class="nav-link scroll">  Solution </a></li>
+
                             <li class="toclevel nav-item"><a href="#Res" class="nav-link scroll">  Results</a></li>
                             <li class="toclevel nav-item"><a href="#References" class="nav-link scroll"> References </a></li>
+
                             <li class="toclevel nav-item"><a href="#Tro" class="nav-link scroll"> Troubleshooting</a></li>
 +
                            <li class="toclevel nav-item"><a href="#Disc" class="nav-link scroll"> Discussion</a></li>
 +
                            <li class="toclevel nav-item"><a href="#Conc" class="nav-link scroll"> Conclusion</a></li>
 +
                            <li class="toclevel nav-item"><a href="#Ref" class="nav-link scroll"> References</a></li>
 +
 
 +
 
 
                         </ul>
 
                         </ul>
 
                 </li>
 
                 </li>
Line 238: Line 243:
 
      
 
      
  
<h1>cDNA Conversion</h1>
+
<h1 id="top">cDNA Conversion</h1>
  
  
Line 244: Line 249:
 
</p>  
 
</p>  
  
<h2>Experiment</h2>
+
<h2 id="Exp">Experiment</h2>
  
<p>The aim of this experiment was the conversion of RNA to cDNA through reverse transcription primed by oligo-dT. The process consists of 3 major steps - complementary DNA strand synthesis, RNA digestion and synthesis of second strand (IDT, 2018). The steps we conducted are described below:<br><br>
+
    <p>The aim of this experiment was the conversion of RNA to cDNA through reverse transcription primed by oligo-dT. The process consists of 3 major steps - complementary DNA strand synthesis, RNA digestion and synthesis of second strand [1]. The steps we conducted are described below:</p><br>
  
<b>Synthesis of complementary DNA strand:</b><br>
+
    <h3>Synthesis of Complementary DNA Strand</h3>
Due to previous polyA addition to 3´OH, all RNA molecules have similar sequence at end which only differs in number of added adenine bases. This allows using polyT primers (Oxford Nanopore) to anneal to RNA template and reverse transcriptase (SuperScript IV, ThermoFisher) can initiate the transcription. <br><br>
+
<p>Due to previous polyA addition to 3'OH, all RNA molecules have similar sequence at 3' end which only differs in number of added adenine bases. This allows us to use polyT primers (Oxford Nanopore) to anneal to RNA template and reverse transcriptase (SuperScript IV, ThermoFisher) can initiate the transcription. <br>
  
A second, so-called strand switching primer is added to the reaction. This compensates for under-representations of 5´ends in cDNA by introducing an additional template and therefore protecting the terminal base pairs. Terminal transferase activity of the RT adds a number of deoxycytidine bases. The SSP primer is complementary to these bases and acts as an extended template for the RT, not only protecting the terminal bases, but also allowing to introduce sequence of choice into the newly synthesized first strand. <br><br>
+
A second, so-called strand switching primer is added to the reaction. This compensates for under-representations of 5´ends in cDNA by introducing an additional template and therefore protecting the terminal base pairs. Terminal transferase activity of the RT adds a number of deoxycytidine bases. The SSP primer is complementary to these bases and acts as an extended template for the RT, not only protecting the terminal bases, but also allowing to introduce sequence of choice into the newly synthesized first strand.</p> <br>
  
<b>RNA template digestion:</b><br>
+
    <h3>RNA Template Digestion</h3>
RNA template needs to be removed before the second DNA strand can be synthesized. This is done by adding ribonucleases (RNAse Cocktail Enzyme Mix, ThermoFischer) into the reaction and incubating. The enzyme mix consists of RNase A and T1. <br><br>
+
    <p>RNA template needs to be removed before the second DNA strand can be synthesized. This is done by adding ribonucleases (RNAse Cocktail Enzyme Mix, ThermoFischer) into the reaction and incubating. The enzyme mix consists of RNase A and T1.</p> <br>
  
<b>Second strand synthesis:</b><br>
+
    <h3>Second Strand Synthesis</h3>
The second DNA strand is synthesized using LongAmp Taq Polymerase (NEB) incubated for one round. Primers used in the reaction are complementary to the sequences introduced by SSP and VNP primers. </p><br>
+
<p>The second DNA strand is synthesized using LongAmp Taq Polymerase (NEB) incubated for one round. Primers used in the reaction are complementary to the sequences introduced by SSP and VNP primers. </p>
  
<h2> Results </h2>
+
<h2 id="Res"> Results </h2>
<p>Initially, very low concentrations of cDNA were achieved. It has been decided to amplify the product using the same primers, which are used for 2nd strand synthesis in order to see if any cDNA was synthesized what so ever. After visulizing the amplified PCR product with cDNA as a template as seen in <b>Figure 1</b>, we could conclude that cDNA was infact successfully synthesized. It has a similiar size distribution as bacterial mRNA, alhought strong band at 270 bp was of unclear origin. <br><br> </p>
+
<p>Initially, very low concentrations of cDNA were achieved. It has been decided to amplify the product using the same primers, which are used for 2nd strand synthesis in order to see if any cDNA was synthesized what so ever. After visulizing the amplified PCR product with cDNA as a template as seen in Figure 1, we could conclude that cDNA was in fact successfully synthesized. It has a similiar size distribution as bacterial mRNA, alhought strong band at 270 bp was of unclear origin. <br><br> </p>
  
 
<p>The remaining task was to ensure that we synthesized enough cDNA. Eventually, we have managed to achieve high yields of cDNA after excessive trouble shooting, which revealed that the reason for low yield was inefficient polyadenylation as described <a href="https://2018.igem.org/Team:Uppsala/Transcriptomics/PolyA_Tailing"> here</a>.<br><br></p>  
 
<p>The remaining task was to ensure that we synthesized enough cDNA. Eventually, we have managed to achieve high yields of cDNA after excessive trouble shooting, which revealed that the reason for low yield was inefficient polyadenylation as described <a href="https://2018.igem.org/Team:Uppsala/Transcriptomics/PolyA_Tailing"> here</a>.<br><br></p>  
Line 272: Line 277:
 
                             <!-- Here you put your paragraphs -->  
 
                             <!-- Here you put your paragraphs -->  
 
                            
 
                            
                             <h3> cDNA yield</h3>
+
                             <h3> cDNA Yield</h3>
 
<p>The amount of cDNA as measured by Qubit (Thermo Fisher). Typically, the cDNA amount would be equal to roughly twice the mass of the input RNA. For 125 ng of mRNA input we have synthesized (in an usual experiment) about 300 ng of cDNA. This amount was sufficient for further experiments.</p>
 
<p>The amount of cDNA as measured by Qubit (Thermo Fisher). Typically, the cDNA amount would be equal to roughly twice the mass of the input RNA. For 125 ng of mRNA input we have synthesized (in an usual experiment) about 300 ng of cDNA. This amount was sufficient for further experiments.</p>
  
   <h3> RNA contamination</h3>
+
   <h3> RNA Contamination</h3>
<p>cDNA which was synthesized during this experiment was used to prepare sequencing library. Due to the suboptimal sequencing performance as described <a href="https://2018.igem.org/Team:Uppsala/Transcriptomics/Sequencing"> here</a>, we began to investigate among other factors the quality of the input cDNA. After extensive troubleshooting it was determined that RNA was still present in the cDNA samples despite digestion and cleaning steps. In several samples very high amount of RNA has been found, often corresponding to the input quantity. RNA content was measured using Qubit HS RNA Kit specific to RNA.  Unfortunately, efficient way of removing RNA has not been found during the course of the project, which is the main reason for poor sequencing results.</p></br>
+
<p>cDNA which was synthesized during this experiment was used to prepare the sequencing library. Due to the suboptimal sequencing performance as described <a href="https://2018.igem.org/Team:Uppsala/Transcriptomics/Sequencing"> here</a>, we began to investigate among other factors the quality of the input cDNA. After extensive troubleshooting it was determined that RNA was still present in the cDNA samples despite digestion and cleaning steps. In several samples very high amount of RNA has been found, often corresponding to the input quantity. RNA content was measured using Qubit HS RNA Kit specific to RNA.  Unfortunately, an efficient way of removing RNA has not been found during the course of the project, which is the main reason for poor sequencing results.</p></br>
  
 
<p>The following section describes the various troubleshooting approaches to investigating the RNA contamination.</p>
 
<p>The following section describes the various troubleshooting approaches to investigating the RNA contamination.</p>
Line 289: Line 294:
 
                           <!-- Here goes the big image to the right -->  
 
                           <!-- Here goes the big image to the right -->  
 
                           <img src="https://static.igem.org/mediawiki/2018/9/99/T--Uppsala--cDNAgel.png" height="75%" id="pic">  
 
                           <img src="https://static.igem.org/mediawiki/2018/9/99/T--Uppsala--cDNAgel.png" height="75%" id="pic">  
                             <p><b>Figure 1:</b> Amplified cDNA using primers provided in the kit shows that cDNA has been indeed synthesized. The sizes correspond approximately to size distribution of bacterial distribution. A strong band (270 bp) is seen which suggests preferential amplification of certain small fragments. </p>
+
                             <p><b>Figure 1.</b> Amplified cDNA using primers provided in the kit shows that cDNA has been indeed synthesized. The sizes correspond approximately to size distribution of bacterial distribution. A strong band (270 bp) is seen which suggests preferential amplification of certain small fragments. </p>
 
                              
 
                              
 
                         </div>
 
                         </div>
Line 299: Line 304:
 
                 <!--End of template with side picture -->
 
                 <!--End of template with side picture -->
  
 +
<div class="card-holder">
 +
<h2 id="Tro">Troubleshooting</h2>
  
<h2>Troubleshooting</h2>
+
<h3>Does Mix of RNA/DNA Interfere with Qubit Measurement?</h3>
 
+
<h3>Does mix of RNA/DNA interfere with Qubit measurement?</h3>
+
  
 
<h4>Hypothesis:</h4>  
 
<h4>Hypothesis:</h4>  
<p>The measured RNA in the sample could be caused due to lack of specificity of Qubit dye eg. RNA dye actually has affinity to DNA and therefore shows RNA in our samples.</p>
+
<p>The measured RNA in the sample could be due to lack of specificity of Qubit dye eg. RNA dye actually has affinity to DNA and therefore shows RNA in our samples.</p>
  
 
<h4>Experiment:</h4>  
 
<h4>Experiment:</h4>  
<p>Samples containing only RNA or DNA in concentration of 10 ng/µl were prepared in triplicate and each measured with two different Qubit kits (RNA HS Kit, DNA HS Kit, Thermo Fisher). </p>
+
<p>Samples containing only RNA or DNA in concentration of 10 ng/µl were prepared in triplicate and each sample was measured with two different Qubit kits (RNA HS Kit, DNA HS Kit, Thermo Fisher). </p>
  
 
<h4>Results:</h4>  
 
<h4>Results:</h4>  
<p>  Measuring RNA (or DNA) with corresponding Kit resulted in expected results eg. around 10 ng of RNA and very low amount of DNA as shown in <b>Table 1</b>. Similar results were seen for DNA sample. When DNA was added into RNA, the measured RNA amount decreased, which was the only measuring bias we have observed. </p><br><br>
+
<p>  Measuring RNA (or DNA) with corresponding Kit resulted in expected results eg. around 10 ng of RNA and very low amount of DNA as shown in Table 1. Similar results were seen for DNA sample. When DNA was added into RNA, the measured RNA amount decreased, which was the only measuring bias we have observed. </p><br><br>
  
  
<p><b>Table 1:</b> The average of measured values for each of the samples. Measuring RNA (or DNA) with corresponding Kit resulted in expected results eg. around 10 ng of RNA and very low amount of DNA. </p>
+
<p><b>Table 1.</b> The average of measured values for each of the samples. Measuring RNA (or DNA) with corresponding Kit resulted in expected results eg. around 10 ng of RNA and very low amount of DNA. </p>
  
 
<table class="pgrouptable tablesorter our-table" style="width: 100%;" cellspacing="0" cellpadding="0">
 
<table class="pgrouptable tablesorter our-table" style="width: 100%;" cellspacing="0" cellpadding="0">
Line 365: Line 370:
  
 
<h4>Conclusion</h4>
 
<h4>Conclusion</h4>
<p>The experiment only investigated interactions between dsDNA and ssRNA, which are not supposed to introduce any bias into the measurement as per manufacturer's information (ThermoFischer, 2018). The remaining question is how would a RNA:DNA hybrid be treated by the dye. It is possible that RNA was not properly digested and therefore remains in the hybrid form. A hybrid could hypothetically be detected by both RNA and DNA specific kit. Unfortunately no proven hybrid sample was available and therefore this hypothesis could not be tested. <br><br>
+
<p>The experiment only investigated interactions between dsDNA and ssRNA, which are not supposed to introduce any bias into the measurement as per manufacturer's information [2]. The remaining question is how would a RNA:DNA hybrid be treated by the dye. It is possible that RNA was not properly digested and therefore remains in the hybrid form. A hybrid could hypothetically be detected by both RNA and DNA specific kit. Unfortunately no proven hybrid sample was available and therefore this hypothesis could not be tested. <br><br>
  
It was concluded that having DNA - RNA mixture does not influence the measurement in a significant way. RNA amount is moderately decreased after addition of DNA into the sample, which would not explain the presence of RNA in cDNA samples. What remains to be investigated is how would a RNA:DNA hybrid influence the measurement. We therefore conclude that the RNA measurement in our samples is accurate and there is RNA present, either as a ssRNA of RNA:DNA hybrid. </p><br><br>
+
It was concluded that having DNA - RNA mixture does not influence the measurement in a significant way. RNA amount is moderately decreased after addition of DNA into the sample, which would not explain the presence of RNA in cDNA samples. What remains to be investigated is how a RNA:DNA hybrid would influence the measurement. We therefore conclude that the RNA measurement in our samples is accurate and there is RNA present, either as a ssRNA or RNA:DNA hybrid. </p><br><br>
  
<h3>Is RNA template properly digested? Is it carried over with the AMPure XP Beads?</h3>
+
<h3>Is RNA Template Properly Digested? Is It Carried Over with the AMPure XP Beads?</h3>
  
 
<h4>Hypothesis:</h4>  
 
<h4>Hypothesis:</h4>  
<p>RNA is found in the final cDNA product as it is not digested properly. The Rnase Cocktail contains RNAse A and T1, which are only supposed to introduce nicks into the RNA. Provided that LongAmp Taq polymerase does not degrade these fragment and that the purification beads (AMPure XP, Agencourt) do have affinity to both RNA and DNA, the RNA would be found in the sample. </p>
+
<p>RNA is found in the final cDNA product as it is not digested properly. The RNase Cocktail contains RNAse A and T1, which are only supposed to introduce nicks into the RNA. Provided that LongAmp Taq polymerase does not degrade these fragment and that the purification beads (AMPure XP, Agencourt) do have affinity to both RNA and DNA, the RNA would be found in the sample. </p>
  
 
<h4>Experiment:</h4>  
 
<h4>Experiment:</h4>  
Line 381: Line 386:
  
 
<h4>Results:</h4>  
 
<h4>Results:</h4>  
<p>Overall, it was seen that subsequent digestion of RNA contaminated samples was successful regardless of used concentration as shown below. Digestion of RNA ladder using RNase H and/or Rnase Cocktail shows complete digestion for RNase Cocktail and RNase H seems not to be working. The beads do carry over most of the RNA including rather small fragments (200 bp). The detailed results of each experiments are shown below:<br></p>
+
<p>Overall, it was seen that subsequent digestion of RNA contaminated samples was successful regardless of used concentration as shown below. Digestion of RNA ladder using RNase H and/or RNase Cocktail shows complete digestion for RNase Cocktail while RNase H seems to not be working. The beads do carry over most of the RNA including rather small fragments (200 bp). The detailed results of each experiments are shown below:<br></p>
 
<br>
 
<br>
 
<p><b>1.</b></p>
 
<p><b>1.</b></p>
Line 388: Line 393:
  
  
<p><b>Table 2:</b> The table shows treatment for 9 samples of RNA and DNA mixture, each containing 125 ng of RNA. *Corresponds to experimental set-up used during the actual cDNA synthesis. <p>
+
<p><b>Table 2.</b> The table shows treatment for 9 samples of RNA and DNA mixture, each containing 125 ng of RNA. *Corresponds to experimental set-up used during the actual cDNA synthesis. <p>
 
<table class="pgrouptable tablesorter our-table" style="width: 100%;" cellspacing="15" cellpadding="0">
 
<table class="pgrouptable tablesorter our-table" style="width: 100%;" cellspacing="15" cellpadding="0">
 
<thead><tr>
 
<thead><tr>
Line 505: Line 510:
 
<p>According to measurement with Qubit RNA HS, all samples regardless of treatment show all RNA being degraded including sample, where treatment is identical to the one used in the actual experiment. </p><br>
 
<p>According to measurement with Qubit RNA HS, all samples regardless of treatment show all RNA being degraded including sample, where treatment is identical to the one used in the actual experiment. </p><br>
  
<p><b>2.</b> The gel below in <b>Figure 2 </b>shows results of digestion of RNA ladder with the available RNases, Rnase H (line 5 and 6) and RNase Cocktail (line 7 and 8) or both (line 8 and 9).<br><br>
+
<p><b>2.</b> The gel below in Figure 2 shows results of the digestion of RNA ladder with the available RNases, RNase H (line 5 and 6) and RNase Cocktail (line 7 and 8) or both (line 8 and 9).<br><br>
  
From this experiment we can conclude that the buffer has no effect on digestion since sample in water and in reaction buffer appear the same. It can further be said that RNase Cocktail efficiently degrades the ladder, which is composed of ssRNA. RNAseH seems to not digest the ladder at all. <br><br>
+
From this experiment we can conclude that the buffer has no effect on digestion since sample in water and in reaction buffer appear the same. It can further be said that RNase Cocktail efficiently degrades the ladder, which is composed of ssRNA. RNase H seems to not digest the ladder at all. <br><br>
  
This corresponds with described ability of RNAseH to preferentially digest RNA:DNA hybrids.</p>
+
This corresponds with described ability of RNase H to preferentially digest RNA:DNA hybrids.</p>
 
      
 
      
 
     </div>
 
     </div>
Line 519: Line 524:
 
</div>
 
</div>
 
<img src="https://static.igem.org/mediawiki/2018/1/10/T--Uppsala--Transcriptomics-cDNAconv.jpg" class="center" height="50%" width="50%" >
 
<img src="https://static.igem.org/mediawiki/2018/1/10/T--Uppsala--Transcriptomics-cDNAconv.jpg" class="center" height="50%" width="50%" >
<p><b>Figure 2:</b> Results after digestion with RNases.</p><br>
+
<p><b>Figure 2.</b> Results after digestion with RNases.</p><br>
  
  
Line 529: Line 534:
 
<p>Overall, the results of this troubleshooting procedure present results conflicting with result of the actual experiment. Here the RNases are shown to work very efficiently. Most likely, RNA used in troubleshooting has different properties that the RNA template in the cDNA synthesis (could be in a form of hybrid or some other unusual form) which leads to different digestion results.</p>
 
<p>Overall, the results of this troubleshooting procedure present results conflicting with result of the actual experiment. Here the RNases are shown to work very efficiently. Most likely, RNA used in troubleshooting has different properties that the RNA template in the cDNA synthesis (could be in a form of hybrid or some other unusual form) which leads to different digestion results.</p>
  
<h2>Discussion</h2>
+
<h2 id="Disc">Discussion</h2>
  
 
<p>During the cDNA synthesis it was possible to achieve sufficiently high yields, usually exceeding double of the input mRNA amount. This cDNA was used to prepare sequencing libraries. As was shown later, it unfortunately contained undigested RNA, which significantly decrease the quality of sequencing results. We have therefore spend significant amount of time searching for the source of RNA contamination as reported in this section. <br><br>
 
<p>During the cDNA synthesis it was possible to achieve sufficiently high yields, usually exceeding double of the input mRNA amount. This cDNA was used to prepare sequencing libraries. As was shown later, it unfortunately contained undigested RNA, which significantly decrease the quality of sequencing results. We have therefore spend significant amount of time searching for the source of RNA contamination as reported in this section. <br><br>
  
The experiments above show very contradicting results. In section i) it can be seen that treatment of cDNA with RNAse Cocktail after synthesis resulted in complete clearance of RNA from the sample. RNase Cocktail has also been shown to digest RNA ladder as visualized on the gel in <b>Figure 1</b>.
+
The experiments above show very contradicting results. In section i) it can be seen that treatment of cDNA with RNase Cocktail after synthesis resulted in complete clearance of RNA from the sample. RNase Cocktail has also been shown to digest RNA ladder as visualized on the gel in Figure 1.
  
 
The same enzyme has always been used during the cDNA synthesis procedure and it remains unclear why does it efficiently digest RNA after synthesis or RNA ladder and would not work during the actual synthesis. <br><br>
 
The same enzyme has always been used during the cDNA synthesis procedure and it remains unclear why does it efficiently digest RNA after synthesis or RNA ladder and would not work during the actual synthesis. <br><br>
  
One hypothesis that we considered was the presence of RNA:DNA hybrids, which would decrease efficiency of RNAse Cocktail, which is more efficient in digesting ssDNA. RNAse H was therefore added to address this issue but clearance of RNA from samples did not significantly increase. Even more confusingly, digestion did work in some of the samples despite the content / treatment being identical. <br><br>
+
One hypothesis that we considered was the presence of RNA:DNA hybrids, which would decrease efficiency of RNase Cocktail, which is more efficient in digesting ssDNA. RNase H was therefore added to address this issue but clearance of RNA from samples did not significantly increase. Even more confusingly, digestion did work in some of the samples despite the content/treatment being identical. <br><br>
  
<h2>Conclusion</h2>
+
<h2 id="Conc">Conclusion</h2>
<p>We have managed to successfully synthesize complementary DNA to our mRNA samples, which unfortunately did contain undigested RNA. A protocol needs to be developed that assures all of the RNA has been removed from the sample prior to the preparation of the library. Moreover, additional troubleshooting needs to be performed to determine why is the digestion not efficient. </p>
+
<p>We have managed to successfully synthesize complementary DNA to our mRNA samples, which unfortunately did contain undigested RNA. A protocol needs to be developed that assures all of the RNA has been removed from the sample prior to the preparation of the library. Moreover, additional troubleshooting needs to be performed to determine why the digestion is not efficient. </p>
  
  
Line 549: Line 554:
  
 
<div class="card-holder">
 
<div class="card-holder">
<h2>References</h2>
+
<h2 id="Ref">References</h2>
  
 
<p><b>[1]</b> IDT, Use of template switching oligos (TS oligos, TSOs) for efficient cDNA library construction, [online], 2018  
 
<p><b>[1]</b> IDT, Use of template switching oligos (TS oligos, TSOs) for efficient cDNA library construction, [online], 2018  
  <a href="https://eu.idtdna.com/pages/education/decoded/article/use-of-template-switching-oligos-(ts-oligos-tsos)-for-efficient-cdna-library-construction">https://eu.idtdna.com/pages/education/decoded/article/use-of-template-switching-oligos-(ts-oligos-tsos)-for-efficient-cdna-library-construction</a> </p><br>
+
  <a href="https://eu.idtdna.com/pages/education/decoded/article/use-of-template-switching-oligos-(ts-oligos-tsos)-for-efficient-cdna-library-construction">https://eu.idtdna.com/pages/education/decoded/article/use-of-template-switching-oligos-(ts-oligos-tsos)-for-efficient-cdna-library-construction</a> </p>
  
<p><b>[1]</b> Thermo Fisher Scientific Inc, User Guide: Qubit RNA HS Assay Kits, [online], 2015  
+
<p><b>[2]</b> Thermo Fisher Scientific Inc, User Guide: Qubit RNA HS Assay Kits, [online], 2015  
 
  <a href="https://www.thermofisher.com/order/catalog/product/Q32852">https://www.thermofisher.com/order/catalog/product/Q32852</a> </p><br>
 
  <a href="https://www.thermofisher.com/order/catalog/product/Q32852">https://www.thermofisher.com/order/catalog/product/Q32852</a> </p><br>
 
</div>
 
</div>

Latest revision as of 16:03, 3 December 2018