Difference between revisions of "Team:Uppsala/Transcriptomics/Barcoding-Library Preparation"

Line 468: Line 468:
 
<h2>Conclusion</h2>
 
<h2>Conclusion</h2>
  
<p>Library preparation is a complex procedure involving multiple enzymes and purification steps. Decreased efficiency of library preparation can be due to malfunctioning of any of the steps. The major issue in prepared libraries has been low sequencing throughput and low quality of reads. We have therefore tested if the issue is somehow connected to our samples or to the actual library prep. Since preparing library from supplied phage DNA was successful (high quality reads, decent throughput), we concluded that the issue was in fact in our input material. This has later proven to be true due to RNA contamination of the libraries as described in cDNA synthesis <b>(LINK)</b>. <br><br>
+
<p>Library preparation is a complex procedure involving multiple enzymes and purification steps. Decreased efficiency of library preparation can be due to malfunctioning of any of the steps. The major issue in prepared libraries has been low sequencing throughput and low quality of reads. We have therefore tested if the issue is somehow connected to our samples or to the actual library prep. Since preparing library from supplied phage DNA was successful (high quality reads, decent throughput), we concluded that the issue was in fact in our input material. This has later proven to be true due to RNA contamination of the libraries as described in cDNA synthesis. <br><br>
  
 
Even with RNA contamination as the potential explanation for low quality reads (RNA is being sequenced using algorithm for DNA and therefore the bases are not being recognized) the problem of low throughput persisted. Major losses are seen during the library prep (up to 75%). According to Oxford Nanopore, this loss is expected, Question is whether it would be worth to increase input material above the recommendation of a manufacturer to achieve higher throughput. <br><br>
 
Even with RNA contamination as the potential explanation for low quality reads (RNA is being sequenced using algorithm for DNA and therefore the bases are not being recognized) the problem of low throughput persisted. Major losses are seen during the library prep (up to 75%). According to Oxford Nanopore, this loss is expected, Question is whether it would be worth to increase input material above the recommendation of a manufacturer to achieve higher throughput. <br><br>

Revision as of 11:08, 15 October 2018