Difference between revisions of "Team:Uppsala/Transcriptomics/Barcoding-Library Preparation"

Line 213: Line 213:
 
                
 
                
  
                     <p>Each sequencing technology has its own mechanism of sequencing. Third generation of sequencing uses pores through which nucleic acid strand is pulled through to read the genetic information. In order to assure that nucleic acids pass the pore at correct speed and orientation, adaptors with motor proteins need to be attached to ends of cDNA molecules. Motor protein then anneals to the pore and pulls the molecule through (Oxford Nanopore, 2018). <br><br>
+
                     <p>Each sequencing technology has its own mechanism of sequencing. Third generation of sequencing uses pores through which nucleic acid strand is pulled through to read the genetic information. In order to assure that nucleic acids pass the pore at correct speed and orientation, adaptors with motor proteins need to be attached to ends of cDNA molecules. Motor protein then anneals to the pore and pulls the molecule through [1]. <br><br>
  
 
                         Other the adaptors, barcodes are also attached to the cDNA sample. In our application, two different samples are sequenced simultaneously using one flow cell. In order to distinguish which molecule belongs to what sample, barcodes (short DNA fragments with known sequence) are ligated to the cDNA. Subsequent bioinformatic analysis allows sorting the reads according to the barcodes and assign them into two distinct samples.  
 
                         Other the adaptors, barcodes are also attached to the cDNA sample. In our application, two different samples are sequenced simultaneously using one flow cell. In order to distinguish which molecule belongs to what sample, barcodes (short DNA fragments with known sequence) are ligated to the cDNA. Subsequent bioinformatic analysis allows sorting the reads according to the barcodes and assign them into two distinct samples.  
Line 223: Line 223:
  
 
                     <h2 id="Res">Results</h2>
 
                     <h2 id="Res">Results</h2>
                     <p>At this stage, the limited amount of material limits ways of assuring that the library preparation was successful. Under normal circumstances, it would be possible to check quality of cDNA library with Nanodrop. But due to rather small volume and concentration, it was decided that only quantity will be measured using Qubit ( (as Nanodrop has shown to not being very accurate below concentrations of 30 ng/µl). Table 1 shows the usual yield in various steps. </p><br><br>
+
                     <p>At this stage, the limited amount of material limits ways of assuring that the library preparation was successful. Under normal circumstances, it would be possible to check quality of cDNA library with Nanodrop. But due to rather small volume and concentration, it was decided that only quantity will be measured using Qubit (as Nanodrop has shown to not being very accurate below concentrations of 30 ng/µl). Table 1 shows the usual yield in various steps. </p><br><br>
  
  

Revision as of 22:48, 17 October 2018