Line 22: | Line 22: | ||
<h3>Safety</h3> | <h3>Safety</h3> | ||
</br> | </br> | ||
− | <p1> Our genetic circuit is activated/deactivated by the redox state of the transcription factor (SoxR). SoxR oxidation is modulated by small redox molecules, such as pyocyanin. However, after Dr. Francesca Ceroni, a PI at Imperial who was pregnant at the time declined to meet us in the lab out of concern of toxic substances as well as <a href="https://2018.igem.org/Team:Imperial_College/Public_Engagement#opinion"><b>public concern</b></a> on the toxicity of our system, we realized that toxicity is a huge factor in downstream implementation of our system. Pyocyanin is a toxin synthesised by the pathogen Pseudomonas aeruginosa and is implicated in its virulence <a href="https://www.sciencedirect.com/science/article/pii/S0924857912002105?via%3Dihub" class="highlight">(https://www.sciencedirect.com/science/article/pii/S0924857912002105?via%3Dihub</a>.) We also realized that using another cheaper redox molecule could not only make our system cheaper to use, but also replace inducer molecules such as IPTG due to their price. Using PMS which is a small redox molecule, we can activate a gene much like IPTG would with p<i>lac</i>. Not only is PMS far cheaper than both pyocyanin and IPTG, it is also non-toxic and makes our system more applicable for real world applications. | + | <p1> Our genetic circuit is activated/deactivated by the redox state of the transcription factor (SoxR). SoxR oxidation is modulated by small redox molecules, such as pyocyanin. However, after Dr. Francesca Ceroni, a PI at Imperial who was pregnant at the time declined to meet us in the lab out of concern of toxic substances as well as <a href="https://2018.igem.org/Team:Imperial_College/Public_Engagement#opinion"><b>public concern</b></a> on the toxicity of our system, we realized that toxicity is a huge factor in downstream implementation of our system. Pyocyanin is a toxin synthesised by the pathogen Pseudomonas aeruginosa and is implicated in its virulence <a href="https://www.sciencedirect.com/science/article/pii/S0924857912002105?via%3Dihub" class="highlight" target="_blank">(https://www.sciencedirect.com/science/article/pii/S0924857912002105?via%3Dihub</a>.) We also realized that using another cheaper redox molecule could not only make our system cheaper to use, but also replace inducer molecules such as IPTG due to their price. Using PMS which is a small redox molecule, we can activate a gene much like IPTG would with p<i>lac</i>. Not only is PMS far cheaper than both pyocyanin and IPTG, it is also non-toxic and makes our system more applicable for real world applications. |
</br></br> | </br></br> | ||
<h4>Toxicity comparison between Pyocyanin and PMS</h4></br> | <h4>Toxicity comparison between Pyocyanin and PMS</h4></br> | ||
− | The 2012 OSHA Hazard Communication Standard ranks hazard ratings with the use of categories, with Category 0 being the lowest risk and Category 4 being the highest. With regards to toxicity, pyocyanin is a Category 4 substance and extreme care was taken during our wet lab to ensure our own safety and any contact with pyocyanin would warrant immediate medical attention, PMS on the other hand is a Category 0 substance and thus is far easier and safer to handle. OSHA pages on PMS <a href="http://datasheets.scbt.com/sc-215700.pdf" class="highlight">(http://datasheets.scbt.com/sc-215700.pdf)</a>: OSHA pages on Pyocyanin <a href="http://datasheets.scbt.com/sds/aghs/en/sc-205475.pdf" class="highlight"> (http://datasheets.scbt.com/sds/aghs/en/sc-205475.pdf)</a>. | + | The 2012 OSHA Hazard Communication Standard ranks hazard ratings with the use of categories, with Category 0 being the lowest risk and Category 4 being the highest. With regards to toxicity, pyocyanin is a Category 4 substance and extreme care was taken during our wet lab to ensure our own safety and any contact with pyocyanin would warrant immediate medical attention, PMS on the other hand is a Category 0 substance and thus is far easier and safer to handle. OSHA pages on PMS <a href="http://datasheets.scbt.com/sc-215700.pdf" class="highlight" target="_blank">(http://datasheets.scbt.com/sc-215700.pdf)</a>: OSHA pages on Pyocyanin <a href="http://datasheets.scbt.com/sds/aghs/en/sc-205475.pdf" class="highlight" target="_blank"> (http://datasheets.scbt.com/sds/aghs/en/sc-205475.pdf)</a>. |
</br></br> | </br></br> | ||
<h4>Cost comparison between PMS and common inducer molecules</h4></br> | <h4>Cost comparison between PMS and common inducer molecules</h4></br> |
Revision as of 12:21, 16 October 2018