Difference between revisions of "Team:Bielefeld-CeBiTec/InterLab"

 
(87 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{:Team:Bielefeld-CeBiTec/Basic_Navbar}}
 
{{:Team:Bielefeld-CeBiTec/Basic_Navbar}}
{{:Team:Bielefeld-CeBiTec/CSS}}
 
  
 
<html>
 
<html>
 
<head>
 
<head>
 +
<link rel="stylesheet" type="text/css"
 +
href="https://2018.igem.org/Team:Bielefeld-CeBiTec/CSS?action=raw&ctype=text/css" />
 
  <link rel="stylesheet" href="https://cdnjs.cloudflare.com/ajax/libs/font-awesome/4.7.0/css/font-awesome.min.css">
 
  <link rel="stylesheet" href="https://cdnjs.cloudflare.com/ajax/libs/font-awesome/4.7.0/css/font-awesome.min.css">
  
 
<script>
 
<script>
 
+
window.onscroll = function() {scrollFunction(); checkOffset();};
window.onscroll = function() {scrollFunction()};
+
  
 
function scrollFunction() {
 
function scrollFunction() {
Line 17: Line 17:
 
}
 
}
 
}
 
}
 +
 +
function checkOffset() {
 +
    if($('#page-arrow-top').offset().top + $('#page-arrow-top').height()
 +
                                          >= $('#footer').offset().top - 10)
 +
        $('#page-arrow-top').css('position', 'absolute');
 +
    if($(document).scrollTop() + window.innerHeight < $('#footer').offset().top)
 +
        $('#page-arrow-top').css('position', 'fixed'); // restore when you scroll up
 +
}
  
 
function topFunction() {
 
function topFunction() {
Line 35: Line 43:
 
 
  
<body style="height:100%;">
+
<body style="height:100%";>
   
+
 
 +
<div class="title_picture">
 +
<img src="https://static.igem.org/mediawiki/2018/1/16/T--Bielefeld-CeBiTec--cycler_vk.png" style="width:100%">
 +
</div>   
 +
 
 +
              <div class="sidenavi" id="side_bar">
 +
 +
<li class="side_list">
 +
<a href="#pro">Protocol</a>
 +
</li>
 +
<li class="side_list">
 +
<a href="#ma">Material</a>
 +
</li>
 +
<li class="side_list">
 +
<a href="#re">Results</a>
 +
</li>
 +
 
 +
</div>
 +
 
 
       <div class="container">
 
       <div class="container">
 
           <div class="main_content">
 
           <div class="main_content">
 
 
 
                  
 
                  
                 <div class="title">Interlab Study</div>
+
                 <div class="title">Interlab Study </div>
  
  <article>
+
   
<br>
+
Reproducibility of results in different laboratories is crucial to facilitate science. We participated in the interlab study to support the iGEM community and provide them with data for the interlab comparison of measurement results.
+
</br>         
+
<h2>Material</h2>
+
  
<br>                                        
+
<article>  
We applied the protocol for plate reader[link] that was provided by the iGEM HQ.         
+
Reproducibility of results in different laboratories is crucial to facilitate science. We participated in the interlab study to support the iGEM community and provide them with data for the comparison of measurement results between different labs. The headquarter has already confirmed that the bronze medal criteria for the interlab study has been fulfilled.   
</br>
+
</article>
<br>
+
   
This year a positive and negative control additionally to six other plasmids containing GFP (green fluorescent protein) genes with different Anderson promoters were transformed into Escherichia coli K-12 DH5α. The following devices were tested:
+
<a name="pro" id="pro" class="shifted-anchor"></a>
</br>
+
<h2>Protocol</h2>
 +
 
 +
<article>                                 
 +
We applied the <a href="https://static.igem.org/mediawiki/2018/0/09/2018_InterLab_Plate_Reader_Protocol.pdf">protocol for plate reader</a> that was provided by the iGEM HQ.         
 +
This year a positive and negative control additionally to six other plasmids containing GFP (green fluorescent protein) genes with different Anderson promoters were transformed into Escherichia coli DH5α. The following devices were tested:
 
<br>
 
<br>
Negative control BBa_R0040: TetR repressible promoter
+
Negative control: BBa_R0040
 
<br>
 
<br>
Positive control BBa_I20270: GFP with weak RBS (ribosomal binding site)
+
Positive control: BBa_I20270
 
<br>
 
<br>
Test Device 1 BBa_J364000
+
Test Device 1: BBa_J364000
 
<br>
 
<br>
Test Device 2 BBa_J364001  
+
Test Device 2: BBa_J364001  
 
<br>
 
<br>
Test Device 3 BBa_J364002  
+
Test Device 3: BBa_J364002  
 
<br>
 
<br>
Test Device 4 BBa_J364007  
+
Test Device 4: BBa_J364007  
 
<br>
 
<br>
Test Device 5 BBa_J364008  
+
Test Device 5: BBa_J364008  
 
<br>
 
<br>
Test Device 6 BBa_J364009  
+
Test Device 6: BBa_J364009  
 
<br>   
 
<br>   
<br>
+
All devices were transformed into <i>Escherichia coli</i> DH5α using 5 µL from the distribution plates. Colonies were picked and colony PCR was conducted to ensure whether transformation with the correct insert was successful. Afterwards the colonies were incubated overnight in 5 mL LB medium and 25 µg mL-1 chloramphenicol.
All devices were transformed into Escherichia coli K-12 DH5α using 5 µL from the distribution plates. Colonies were picked and colony PCR was conducted to ensure whether transformation with the correct insert was successful. Afterwards the colonies were incubated overnight in 5 mL LB medium and 25 µg mL-1 chloramphenicol.
+
For measurements two cultures of each device were grown overnight in 5 mL LB media with 25 µg mL<sup>-1</sup> chloramphenicol at 37 °C.
For measurements two cultures of each plate were picked and grown overnight in 5 mL LB media with 25 µg mL<sup>-1</sup> chloramphenicol at 37 °C.
+
</br>
+
 
<br>
 
<br>
 
The bacteria cultures were diluted to OD<sub>600</sub> of 0.02 in a total volume of 12 mL LB with 25 µg mL<sup>-1</sup> chloramphenicol in 50 mL falcon tubes covered in foil and incubated in darkness for 6 hours at 37&nbsp;°C and 220 rpm. 500 µL samples were taken after 0 and 6 hours of incubation and stored on ice until the measurement. Absorbance was measured by OD<sub>600</sub>, fluorescence by excitation at 485 nm and emission at 530 nm.
 
The bacteria cultures were diluted to OD<sub>600</sub> of 0.02 in a total volume of 12 mL LB with 25 µg mL<sup>-1</sup> chloramphenicol in 50 mL falcon tubes covered in foil and incubated in darkness for 6 hours at 37&nbsp;°C and 220 rpm. 500 µL samples were taken after 0 and 6 hours of incubation and stored on ice until the measurement. Absorbance was measured by OD<sub>600</sub>, fluorescence by excitation at 485 nm and emission at 530 nm.
</br>
 
 
<br>
 
<br>
 
To determine the amount of colony forming units (CFU) per mL the overnight culture of the negative and positive control were diluted to OD<sub>600</sub> 0.1 in LB medium with 25 µg mL<sup>-1</sup> chloramphenicol in a total volume of 1 mL. The culture was further diluted in LB medium with 25 µg mL-1 chloramphenicol in five dilutions steps according to figure 1. Dilution steps three, four and five were put on LB plates containing  25 µg mL<sup>-1</sup> chloramphenicol and incubated overnight.
 
To determine the amount of colony forming units (CFU) per mL the overnight culture of the negative and positive control were diluted to OD<sub>600</sub> 0.1 in LB medium with 25 µg mL<sup>-1</sup> chloramphenicol in a total volume of 1 mL. The culture was further diluted in LB medium with 25 µg mL-1 chloramphenicol in five dilutions steps according to figure 1. Dilution steps three, four and five were put on LB plates containing  25 µg mL<sup>-1</sup> chloramphenicol and incubated overnight.
 
</br>
 
</br>
 
</article>
 
</article>
                    <figure role="group">
+
 
 +
<figure role="group">
 
                       <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/d/d0/T--Bielefeld-CeBiTec--InterlabStudyDilutionPlan_MO.png">
 
                       <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/d/d0/T--Bielefeld-CeBiTec--InterlabStudyDilutionPlan_MO.png">
 
                       <figcaption>
 
                       <figcaption>
                           <b>Figure 1:Dilution steps for measuring the CFU per mL of the negative and positive control. Figure from iGEM Headquarter </b>
+
                           <b>Figure 1: </b>Dilution steps for measuring the CFU per mL of the negative and positive control. Figure from <a href="https://static.igem.org/mediawiki/2018/0/09/2018_InterLab_Plate_Reader_Protocol.pdf">iGEM Headquarter</a>.
 
                       </figcaption>
 
                       </figcaption>
                  </figure>
+
</figure>
 +
 
 +
<a name="ma" id="ma" class="shifted-anchor"></a>                                                           
 +
<h2>Material</h2>
 +
 
 
<article>
 
<article>
<br>
+
                                                       
                                                           
+
<h2>Material</h2>
+
</br>
+
<br>                                                       
+
 
Incubator: We used the GFL Type 30/32 incubator at 37 °C and 220 rpm. We covered the glass front with paper to make sure the samples grew in darkness.
 
Incubator: We used the GFL Type 30/32 incubator at 37 °C and 220 rpm. We covered the glass front with paper to make sure the samples grew in darkness.
</br>
 
 
<br>                   
 
<br>                   
 
Cuvette measurement: For the first OD<sub>600</sub> measurement of the overnight cultures we used an Eppendorf 6131 BioPhotometer.
 
Cuvette measurement: For the first OD<sub>600</sub> measurement of the overnight cultures we used an Eppendorf 6131 BioPhotometer.
</br>
 
 
<br>                   
 
<br>                   
 
Plate reader: Our plate reader model was the Tecan Infinite M200 (Roche). The excitation wavelength was set to 485 nm and emission wavelength was detected at 530 nm [1].
 
Plate reader: Our plate reader model was the Tecan Infinite M200 (Roche). The excitation wavelength was set to 485 nm and emission wavelength was detected at 530 nm [1].
</br>
 
 
<br>                   
 
<br>                   
96 well plate: We used the 96 well microplates in black (polystyrene) from Greiner Bio-One  for our measurements with the plate reader.
+
96 well plate: We used the 96 well microplates in black (polystyrene) from Greiner Bio-One  for our measurements with the plate reader.                                                 
</br>                                                  
+
 
<br>     
 
<br>     
E. coli strains
+
<i>E. coli strains</i>
</br>
+
 
<br>                                       
 
<br>                                       
E. coli DH5-α
+
<i>E. coli</i> DH5α
</br>
+
<br>  
<br>                  
+
</article>       
 +
       
 +
<a name="re" id="re" class="shifted-anchor"></a> 
 
<h2>Results</h2>  
 
<h2>Results</h2>  
</br>
+
 
 +
<article>
 +
In order to quantify the results of the Interlab Study two standard measurements have been carried out.The first standard curve shows the measures fluorescence of fluorescein in different concentrations (Figure 2) and the second standard curve shows absorption measurements of silica beads in different dilutions.
 +
</article>
  
 
<figure role="group">
 
<figure role="group">
 
                       <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/2/2c/T--Bielefeld-CeBiTec--InterlabStudyFluoresceinStandard_MO.png">
 
                       <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/2/2c/T--Bielefeld-CeBiTec--InterlabStudyFluoresceinStandard_MO.png">
 
                       <figcaption>
 
                       <figcaption>
                           <b>Figure 2:Fluorescein Standard curve. </b>
+
                           <b>Figure 2: </b>Fluorescein Standard curve. Fluorescein standard curve for calibration before measurements. Fluorescein has a similar emission and excitation as GFP. As all instruments vary in measurement units it is important to calibrate each instrument.
 
                       </figcaption>
 
                       </figcaption>
                  </figure>
+
</figure>
 +
 
 +
 
 +
<figure role="group">
 +
                      <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/d/de/T--Bielefeld-CeBiTec--InterlabStudyParticleStandard_MO.png">
 +
                      <figcaption>
 +
                          <b>Figure 3: </b>Particle Standard curve. Silica beads were diluted and absorption at 600 nm was measured. This enables calibration of absorption measurement of the instrument.
 +
                      </figcaption>
 +
</figure>
 +
 
 
<article>
 
<article>
balalba
+
Cultures were treated as described in the <a href="https://static.igem.org/mediawiki/2018/0/09/2018_InterLab_Plate_Reader_Protocol.pdf">protocol</a>. The overnight cultures were diluted to OD<sub>600</sub> 0.02 and cultivated at 37 °C and 220 rpm for six hours. Samples were taken after 0 h and 6 h. The OD<sub>600</sub> and fluorescence of all samples were measured. The OD<sub>600</sub> after 0 h and 6 h can be seen in figure 4. The fluorescence of the samples after 0 h and 6 h can be seen in figure 5.
 +
<br>In both figures it becomes clear that the growth of the colony seems to be independent from the fluorescence. The negative control shows of course the smallest fluorescence. The highest fluorescence has device 1 followed by device 4. Device 6 and 4 show the smallest fluorescence of the devices. The highest OD<sub>600</sub> after 6 hours has the negative control and device 3. Device 5 reveals the slowest growth after 6 hours but does not show the smallest fluorescence.</br>
 
</article>
 
</article>
<br>
 
  
 
<figure role="group">
 
<figure role="group">
                       <img class="https://static.igem.org/mediawiki/2018/d/de/T--Bielefeld-CeBiTec--InterlabStudyParticleStandard_MO.png">
+
                       <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/c/ca/T--Bielefeld-CeBiTec--InterlabStudyOD600_MO.png">
 
                       <figcaption>
 
                       <figcaption>
                           <b>Figure 3:Particle Standard curve. </b>
+
                           <b>Figure 4: </b> OD<sub>600</sub> after 0 h and 6 h of the negative control, positive control and the six test devices.
 
                       </figcaption>
 
                       </figcaption>
                  </figure>
+
</figure>
  
  
<html>
+
<figure role="group">
 +
                      <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/8/8a/T--Bielefeld-CeBiTec--InterlabStudyFluorescence_MO.png">
 +
                      <figcaption>
 +
                          <b>Figure 5: </b> Fluorescence after 0h and 6h of the negative control, positive control and the six test devices.
 +
                      </figcaption>
 +
</figure>
 +
 
 +
 
 +
<article>
 +
Furthermore the colony forming units per 0.1 OD<sub>600</sub> of the positive and the negative control were determined. Overnight cultures were diluted to an OD<sub>600</sub> of 0.1. The samples were diluted as seen in figure 1. Dilutions 3,4 and 5 were put on LB Agar + chloramphenicol plates. The CFU of the positive and the negative control is illustrated in figure 6.
 +
</article>
 +
<figure role="group">
 +
                      <img class="figure eighty" src="https://static.igem.org/mediawiki/2018/4/46/T--Bielefeld-CeBiTec--CFU_MO.png">
 +
                      <figcaption>
 +
                          <b>Figure 6: </b> Colony Forming Units (CFU) of the Negative and the Positive Control. Dilution 3, 4 and 5 of both cultures were considered.
 +
                      </figcaption>
 +
</figure>
 +
 
 +
 
 +
<table id="t01" class="centern">
 +
<caption class="table_caption"> <b>Table 1:</b> Colony forming units (CFU) of different dilutions of the negative and the positive control.</caption>
 +
  <tr>
 +
<th>Negative Control</th>
 +
 
 +
<th>Dilution 3 [CFU x mL<sup>-1</sup>]</th>
 +
<th>Dilution 4 [CFU x mL<sup>-1</sup>]</th>
 +
<th>Dilution 5 [CFU x mL<sup>-1</sup>]</th>
 +
  </tr>
 +
  <tr>
 +
 
 +
<th>Colony 1</th>
 +
<td>1,10 x 10<sup>8</sup></td>
 +
<td>8,48 x 10<sup>7</sup></td>
 +
<td>1,12 x 10<sup>8</sup></td>
 +
  </tr>
 +
  <tr>
 +
<th></th>
 +
<td>7,38 x 10<sup>7</sup></td>
 +
<td>6,56 x 10<sup>7</sup></td>
 +
<td>8,00 x 10<sup>7</sup></td>
 +
  </tr>
 +
  <tr>
 +
<th></th>
 +
<td>1,01 x 10<sup>8</sup></td>
 +
<td>1,00 x 10<sup>8</sup></td>
 +
<td>1,28 x 10<sup>8</sup></td>
 +
  </tr>
 +
<tr>
 +
<th>Colony 2</th>
 +
<td>9,15 x 10<sup>7</sup></td>
 +
<td>1,05 x 10<sup>8</sup></td>
 +
<td>9,60 x 10<sup>7</sup></td>
 +
  </tr>
 +
<tr>
 +
<th></th>
 +
<td>9,78 x 10<sup>7</sup></td>
 +
<td>9,52 x 10<sup>7</sup></td>
 +
<td>1,20 x 10<sup>8</sup></td>
 +
  </tr>
 +
<tr>
 +
<th></th>
 +
<td>1,03 x 10<sup>8</sup></td>
 +
<td>9,84 x 10<sup>7</sup></td>
 +
<td>1,36 x 10<sup>8</sup></td>
 +
  </tr>
 +
<tr>
 +
<th>Positive Control</th>
 +
 
 +
 +
  </tr>
 +
 
 +
<th>Colony 1</th>
 +
<td>9,47 x 10<sup>7</sup></td>
 +
<td>1,05 x 10<sup>8</sup></td>
 +
<td>9,60 x 10<sup>7</sup></td>
 +
  </tr>
 +
  <tr>
 +
<th></th>
 +
<td>1,15 x 10<sup>8</sup></td>
 +
<td>1,15 x 10<sup>8</sup></td>
 +
<td>8,80 x 10<sup>7</sup></td>
 +
  </tr>
 +
  <tr>
 +
<th></th>
 +
<td>7,84 x 10<sup>7</sup></td>
 +
<td>8,72 x 10<sup>7</sup></td>
 +
<td>6,40 x 10<sup>7</sup></td>
 +
  </tr>
 +
<tr>
 +
<th>Colony 2</th>
 +
<td>9,22 x 10<sup>7</sup></td>
 +
<td>8,96 x 10<sup>7</sup></td>
 +
<td>7,20 x 10<sup>7</sup></td>
 +
  </tr>
 +
<tr>
 +
 
 +
<th></th>
 +
<td>8,54 x 10<sup>7</sup></td>
 +
<td>1,14 x 10<sup>8</sup></td>
 +
<td>9,60 x 10<sup>7</sup></td>
 +
  </tr>
 +
<tr>
 +
<th></th>
 +
<td>8,48 x 10<sup>7</sup></td>
 +
<td>9,68 x 10<sup>7</sup></td>
 +
<td>1,04 x 10<sup>8</sup></td>
 +
  </tr>
 +
 
 +
 
 +
 
 +
 
 +
</table>
 +
<br>
 +
</br>
 +
 
 +
                   
 +
                  </div>
 +
                 
 +
 
 +
 +
 
 +
    </div>
 +
 
 +
 
 +
<!-- Footer -->
 +
<footer id="footer" class="w3-container w3-padding-32 w3-center w3-black w3-xlarge" style="position: absolute; width:100%; z-index:200;">
 +
  <a class="footer-icon" href="https://www.facebook.com/igembielefeld/"> <i class="fa fa-facebook-official" ></i></a>
 +
  <a class="footer-icon" href="https://www.instagram.com/igem.bielefeld/?hl=de"><i class="fa fa-instagram"></i></a>
 +
  <a class="footer-icon" href="https://twitter.com/iGEM_Bielefeld"><i class="fa fa-twitter"></i></a>
 +
</footer>
 +
 
 +
<img id="page-arrow-top"  src="https://static.igem.org/mediawiki/2018/7/7e/T--Bielefeld-CeBiTec--top_arrow_white_vk.png" style="width:3%" onclick="topFunction()"></img>
 +
 
 +
      </div>
 +
 
 +
       
 +
 
 +
 
 +
 
 +
 
 +
 
 +
</body>
 +
 
 +
</html>

Latest revision as of 02:42, 18 October 2018

Interlab Study
Reproducibility of results in different laboratories is crucial to facilitate science. We participated in the interlab study to support the iGEM community and provide them with data for the comparison of measurement results between different labs. The headquarter has already confirmed that the bronze medal criteria for the interlab study has been fulfilled.

Protocol

We applied the protocol for plate reader that was provided by the iGEM HQ. This year a positive and negative control additionally to six other plasmids containing GFP (green fluorescent protein) genes with different Anderson promoters were transformed into Escherichia coli DH5α. The following devices were tested:
Negative control: BBa_R0040
Positive control: BBa_I20270
Test Device 1: BBa_J364000
Test Device 2: BBa_J364001
Test Device 3: BBa_J364002
Test Device 4: BBa_J364007
Test Device 5: BBa_J364008
Test Device 6: BBa_J364009
All devices were transformed into Escherichia coli DH5α using 5 µL from the distribution plates. Colonies were picked and colony PCR was conducted to ensure whether transformation with the correct insert was successful. Afterwards the colonies were incubated overnight in 5 mL LB medium and 25 µg mL-1 chloramphenicol. For measurements two cultures of each device were grown overnight in 5 mL LB media with 25 µg mL-1 chloramphenicol at 37 °C.
The bacteria cultures were diluted to OD600 of 0.02 in a total volume of 12 mL LB with 25 µg mL-1 chloramphenicol in 50 mL falcon tubes covered in foil and incubated in darkness for 6 hours at 37 °C and 220 rpm. 500 µL samples were taken after 0 and 6 hours of incubation and stored on ice until the measurement. Absorbance was measured by OD600, fluorescence by excitation at 485 nm and emission at 530 nm.
To determine the amount of colony forming units (CFU) per mL the overnight culture of the negative and positive control were diluted to OD600 0.1 in LB medium with 25 µg mL-1 chloramphenicol in a total volume of 1 mL. The culture was further diluted in LB medium with 25 µg mL-1 chloramphenicol in five dilutions steps according to figure 1. Dilution steps three, four and five were put on LB plates containing 25 µg mL-1 chloramphenicol and incubated overnight.
Figure 1: Dilution steps for measuring the CFU per mL of the negative and positive control. Figure from iGEM Headquarter.

Material

Incubator: We used the GFL Type 30/32 incubator at 37 °C and 220 rpm. We covered the glass front with paper to make sure the samples grew in darkness.
Cuvette measurement: For the first OD600 measurement of the overnight cultures we used an Eppendorf 6131 BioPhotometer.
Plate reader: Our plate reader model was the Tecan Infinite M200 (Roche). The excitation wavelength was set to 485 nm and emission wavelength was detected at 530 nm [1].
96 well plate: We used the 96 well microplates in black (polystyrene) from Greiner Bio-One for our measurements with the plate reader.
E. coli strains
E. coli DH5α

Results

In order to quantify the results of the Interlab Study two standard measurements have been carried out.The first standard curve shows the measures fluorescence of fluorescein in different concentrations (Figure 2) and the second standard curve shows absorption measurements of silica beads in different dilutions.
Figure 2: Fluorescein Standard curve. Fluorescein standard curve for calibration before measurements. Fluorescein has a similar emission and excitation as GFP. As all instruments vary in measurement units it is important to calibrate each instrument.
Figure 3: Particle Standard curve. Silica beads were diluted and absorption at 600 nm was measured. This enables calibration of absorption measurement of the instrument.
Cultures were treated as described in the protocol. The overnight cultures were diluted to OD600 0.02 and cultivated at 37 °C and 220 rpm for six hours. Samples were taken after 0 h and 6 h. The OD600 and fluorescence of all samples were measured. The OD600 after 0 h and 6 h can be seen in figure 4. The fluorescence of the samples after 0 h and 6 h can be seen in figure 5.
In both figures it becomes clear that the growth of the colony seems to be independent from the fluorescence. The negative control shows of course the smallest fluorescence. The highest fluorescence has device 1 followed by device 4. Device 6 and 4 show the smallest fluorescence of the devices. The highest OD600 after 6 hours has the negative control and device 3. Device 5 reveals the slowest growth after 6 hours but does not show the smallest fluorescence.
Figure 4: OD600 after 0 h and 6 h of the negative control, positive control and the six test devices.
Figure 5: Fluorescence after 0h and 6h of the negative control, positive control and the six test devices.
Furthermore the colony forming units per 0.1 OD600 of the positive and the negative control were determined. Overnight cultures were diluted to an OD600 of 0.1. The samples were diluted as seen in figure 1. Dilutions 3,4 and 5 were put on LB Agar + chloramphenicol plates. The CFU of the positive and the negative control is illustrated in figure 6.
Figure 6: Colony Forming Units (CFU) of the Negative and the Positive Control. Dilution 3, 4 and 5 of both cultures were considered.
Table 1: Colony forming units (CFU) of different dilutions of the negative and the positive control.
Negative Control Dilution 3 [CFU x mL-1] Dilution 4 [CFU x mL-1] Dilution 5 [CFU x mL-1]
Colony 1 1,10 x 108 8,48 x 107 1,12 x 108
7,38 x 107 6,56 x 107 8,00 x 107
1,01 x 108 1,00 x 108 1,28 x 108
Colony 2 9,15 x 107 1,05 x 108 9,60 x 107
9,78 x 107 9,52 x 107 1,20 x 108
1,03 x 108 9,84 x 107 1,36 x 108
Positive Control
Colony 1 9,47 x 107 1,05 x 108 9,60 x 107
1,15 x 108 1,15 x 108 8,80 x 107
7,84 x 107 8,72 x 107 6,40 x 107
Colony 2 9,22 x 107 8,96 x 107 7,20 x 107
8,54 x 107 1,14 x 108 9,60 x 107
8,48 x 107 9,68 x 107 1,04 x 108