(4 intermediate revisions by the same user not shown) | |||
Line 33: | Line 33: | ||
<li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Experiments"><span>Experiments</span></a></li> | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Experiments"><span>Experiments</span></a></li> | ||
</li> | </li> | ||
− | <li class=" | + | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Interlab"><span>Interlab</span></a></li> |
</li> | </li> | ||
<li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Demonstrate"><span>Demonstrate</span></a></li> | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Demonstrate"><span>Demonstrate</span></a></li> | ||
Line 54: | Line 54: | ||
<li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Engagement"><span>Engagement</span></a></li> | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Engagement"><span>Engagement</span></a></li> | ||
</li> | </li> | ||
− | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/ | + | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/IAT"><span>Iat</span></a></li> |
</li> | </li> | ||
<li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Societal_Considerations"><span>Societal Considerations</span></a></li> | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Societal_Considerations"><span>Societal Considerations</span></a></li> | ||
</li> | </li> | ||
</ul> | </ul> | ||
− | <li class="dropdown nav-item"><a href="#" class="nav-link dropdown-toggle nav-link" data-toggle="dropdown" role="button" aria-haspopup="true" aria-expanded="false"> | + | <li class="dropdown nav-item"><a href="#" class="nav-link dropdown-toggle nav-link" data-toggle="dropdown" role="button" aria-haspopup="true" aria-expanded="false">Dry Lab<span class="caret"></span></a> |
<ul class="dropdown-menu"> | <ul class="dropdown-menu"> | ||
+ | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Model"><span>Model</span></a></li> | ||
+ | </li> | ||
<li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Software"><span>Software</span></a></li> | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Software"><span>Software</span></a></li> | ||
</li> | </li> | ||
− | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/ | + | <li class=""><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Automation"><span>Automation</span></a></li> |
+ | </li> | ||
+ | <li class="active"><a class="dropdown-item" href="https://2018.igem.org/Team:Waterloo/Turbidostat"><span>Turbidostat</span></a></li> | ||
</li> | </li> | ||
</ul> | </ul> | ||
Line 70: | Line 74: | ||
<div class="content"> | <div class="content"> | ||
− | <div class="titleBox row | + | <div class="titleBox row"> |
− | <div class="layer | + | <div class="layer"> |
<div class="squiggle squiggleForward col-xs-4"></div> | <div class="squiggle squiggleForward col-xs-4"></div> | ||
<div class="titleCaption col-xs-4"> | <div class="titleCaption col-xs-4"> | ||
Line 82: | Line 86: | ||
</div> | </div> | ||
− | <div class="row"><div class="col"><div class="content-main"><p>A turbidostat is a machine capable of maintaining the optical density, or turbidity, of a cell culture in liquid medium. Brian Ingalls, one of the principal investigators supervising the Waterloo iGEM team, commissioned Mark Soric, an associate of the lab, to make a turbidostat from scratch for use in the Ingalls lab. | + | <div class="row"><div class="col"><div class="content-main"><p>A turbidostat is a machine capable of maintaining the optical density, or turbidity, of a cell culture in liquid medium. Dr. Brian Ingalls, one of the principal investigators supervising the Waterloo iGEM team, and Dr. Matt Scott commissioned Mark Soric, an associate of the lab, to make a turbidostat from scratch for use in the Ingalls lab.</p> |
− | <p>Turbidostats are not widely available on the market, and | + | <p>Turbidostats are not widely available on the market, and there are currently few companies capable of tailor-making them for specific projects. The first generation of Mark Soric's design is in the Ingalls lab, and the second generation model is currently under construction. </p> |
− | < | + | <center><img src="https://static.igem.org/mediawiki/2018/1/19/T--Waterloo--turbidostatEntire.jpg" /></center> |
+ | |||
<p>The basic design has the following components:</p> | <p>The basic design has the following components:</p> | ||
<ul> | <ul> | ||
Line 94: | Line 99: | ||
<li>A vacuum connected to the Arduino</li> | <li>A vacuum connected to the Arduino</li> | ||
<li>A vacuum manifold connected to the PCB</li> | <li>A vacuum manifold connected to the PCB</li> | ||
− | <li>A 3D-printed sample vial holder, which the PCB is | + | <li>A 3D-printed sample vial holder, which houses the PCB and is bound to the vacuum manifold</li> |
<li>A 37°C incubator that contains the PCB and its associated components</li> | <li>A 37°C incubator that contains the PCB and its associated components</li> | ||
</ul> | </ul> | ||
− | <p>The machine functions as | + | <p>The machine functions as described in the following paragraphs. 40 mL sample vials are placed in the 3D printed holder, and filled with approximately 25 mL of culture. The motors connected to the PCB alternate between spinning and being still, which controls a magnetic stir bar to aerate the sample. </p> |
− | <p>The cells | + | <p>The cells do not settle down to the bottom of the vial when the motors are not stirring. However, the liquid in the vial must settle for at least 1 minute before the machine can take an accurate turbidity measurement, to prevent interference from bubbles and swirling cells. The turbidostat measures OD by shining a red LED through the sample and measuring the amount of light that passes through the sample via a photodiode opposite the LED. Before operation, a spectrophotometer is used to generate an OD calibration curve of OD to compare with the photodiode readings. </p> |
− | <p> | + | <p>In addition to a liquid sample and a stir bar, the sample vial has a lid attached to it with three ports. The first port connects to an air filter, allowing oxygen, but not dust, to travel into the containerh. The second port is a feed line, through which new liquid media can be delivered. The third is a waste line, where old media is removed via vacuum. See below for a video of a sample vial being stirred.</p> |
− | <video width="100%" height="480" controls> | + | <video width="100%" height="480" controls> |
− | <source src="" type="video/mp4"> | + | <source src="https://static.igem.org/mediawiki/2018/f/ff/T--Waterloo--turbidostatInterior.mov" type="video/mp4"> |
</video> | </video> | ||
− | <p>The | + | <p>The feed line, waste line, and LED-photodiode enable the turbidostat to maintain OD. When the OD passes a threshold, specified in the computer program and determined by the LED-photodiode pair, the following happens:</p> |
<ol> | <ol> | ||
− | <li>The peristaltic pump associated with the sample vial that passed the threshold is activated. The pump moves | + | <li>The peristaltic pump associated with the sample vial that passed the threshold is activated. The pump moves about 5 mL of liquid media from a source vial outside the incubator through the feed line and into the sample vial.</li> |
<li>The motor attached to the PCB that is associated with the vial of interest turns on. This spins the stir bar and mixes the new media with the media already in the vial.</li> | <li>The motor attached to the PCB that is associated with the vial of interest turns on. This spins the stir bar and mixes the new media with the media already in the vial.</li> | ||
− | <li>The motor turns off and the vacuum activates. This removes a volume of media equivalent to that which was | + | <li>The motor turns off and the vacuum activates. This removes a volume of media equivalent to that which was inputted in step 1 and completes the dilution process.</li> |
</ol> | </ol> | ||
<p>See below for a demonstration of step 1 (one can also hear the vacuum activating in step 3 in the background):</p> | <p>See below for a demonstration of step 1 (one can also hear the vacuum activating in step 3 in the background):</p> | ||
− | <video width="100%" height="480" controls> | + | <video width="100%" height="480" controls> |
− | <source src="" type="video/mp4"> | + | <source src="https://static.igem.org/mediawiki/2018/f/f3/T--Waterloo--turbidostatPeristalticPump.mov" type="video/mp4"> |
</video> | </video> | ||
− | <p>Upon leaving the sample vial, the extra media passes first through an intermediate vial, | + | |
− | <p>Another interesting and | + | <p>Upon leaving the sample vial, the extra media passes first through an intermediate vial, then a final waste vial. The intermediate vial is present in the event that the user wants to sample some of the most recent flushed contents, and the container is easily replaceable to allow multiple subsequent samples as necessary. The final waste vial collects unwanted cells.</p> |
+ | <p>Another interesting and important aspect of the turbidostat is that it is able to subject vials to time varying amounts of red and green light. There are red and green LEDs built into the PCB, and their intensities can be controlled via the associated MatLab program. This allows manipulation of the optogenetic system relevant to this project, while maintaining cells at a constant OD. The turbidostat also enables our team to perform long experiments, essential for this project.</p> | ||
<p>See the image below for the GUI of the turbidostat’s MatLab program (designed primarily by Mark Soric) and its assorted ancilliary data.</p> | <p>See the image below for the GUI of the turbidostat’s MatLab program (designed primarily by Mark Soric) and its assorted ancilliary data.</p> | ||
− | < | + | <center><img src="https://static.igem.org/mediawiki/2018/a/a2/T--Waterloo--turbidostatControlCenter.jpg" /></center> |
</div></div></div> | </div></div></div> | ||
</div> | </div> |
Latest revision as of 05:10, 1 December 2018
Turbidostat
A turbidostat is a machine capable of maintaining the optical density, or turbidity, of a cell culture in liquid medium. Dr. Brian Ingalls, one of the principal investigators supervising the Waterloo iGEM team, and Dr. Matt Scott commissioned Mark Soric, an associate of the lab, to make a turbidostat from scratch for use in the Ingalls lab.
Turbidostats are not widely available on the market, and there are currently few companies capable of tailor-making them for specific projects. The first generation of Mark Soric's design is in the Ingalls lab, and the second generation model is currently under construction.
The basic design has the following components:
- A MatLab program run off of a personal computer
- An Arduino Mega connected to the computer
- A printed circuit board (PCB) connected to the Arduino
- A series of sample-stirring motors connected to the PCB
- A collection of peristaltic pumps connected to the Arduino
- A vacuum connected to the Arduino
- A vacuum manifold connected to the PCB
- A 3D-printed sample vial holder, which houses the PCB and is bound to the vacuum manifold
- A 37°C incubator that contains the PCB and its associated components
The machine functions as described in the following paragraphs. 40 mL sample vials are placed in the 3D printed holder, and filled with approximately 25 mL of culture. The motors connected to the PCB alternate between spinning and being still, which controls a magnetic stir bar to aerate the sample.
The cells do not settle down to the bottom of the vial when the motors are not stirring. However, the liquid in the vial must settle for at least 1 minute before the machine can take an accurate turbidity measurement, to prevent interference from bubbles and swirling cells. The turbidostat measures OD by shining a red LED through the sample and measuring the amount of light that passes through the sample via a photodiode opposite the LED. Before operation, a spectrophotometer is used to generate an OD calibration curve of OD to compare with the photodiode readings.
In addition to a liquid sample and a stir bar, the sample vial has a lid attached to it with three ports. The first port connects to an air filter, allowing oxygen, but not dust, to travel into the containerh. The second port is a feed line, through which new liquid media can be delivered. The third is a waste line, where old media is removed via vacuum. See below for a video of a sample vial being stirred.
The feed line, waste line, and LED-photodiode enable the turbidostat to maintain OD. When the OD passes a threshold, specified in the computer program and determined by the LED-photodiode pair, the following happens:
- The peristaltic pump associated with the sample vial that passed the threshold is activated. The pump moves about 5 mL of liquid media from a source vial outside the incubator through the feed line and into the sample vial.
- The motor attached to the PCB that is associated with the vial of interest turns on. This spins the stir bar and mixes the new media with the media already in the vial.
- The motor turns off and the vacuum activates. This removes a volume of media equivalent to that which was inputted in step 1 and completes the dilution process.
See below for a demonstration of step 1 (one can also hear the vacuum activating in step 3 in the background):
Upon leaving the sample vial, the extra media passes first through an intermediate vial, then a final waste vial. The intermediate vial is present in the event that the user wants to sample some of the most recent flushed contents, and the container is easily replaceable to allow multiple subsequent samples as necessary. The final waste vial collects unwanted cells.
Another interesting and important aspect of the turbidostat is that it is able to subject vials to time varying amounts of red and green light. There are red and green LEDs built into the PCB, and their intensities can be controlled via the associated MatLab program. This allows manipulation of the optogenetic system relevant to this project, while maintaining cells at a constant OD. The turbidostat also enables our team to perform long experiments, essential for this project.
See the image below for the GUI of the turbidostat’s MatLab program (designed primarily by Mark Soric) and its assorted ancilliary data.