<p> The Fifth International InterLaboratory Measurement Study is one of the largest collaborative studies ever performed in synthetic biology, featuring the work of iGEM teams across the world. Each annual iteration of the study is dedicated to identifying and rectifying sources of variability in measurements and protocols across lab settings. This year’s edition primarily focused on standardizing absorbance and fluorescence measurements of GFP-expressing bacteria, correcting for human and machine variability across labs. </p>
 +
<p> Per the iGEM protocol, we transformed New England Biosciences 5-alpha E. coli with the eight following plasmids from the iGEM Distribution Kit 7: </p>
 +
<ul>
 +
<li> Positive Control: BBa_I20270 </li>
 +
<li> Negative Control: BBa_R0040 </li>
 +
<li> Test Device 1: BBa_J364000 </li>
 +
<li> Test Device 2: BBa_J364001 </li>
 +
<li> Test Device 3: BBa_J364002 </li>
 +
<li> Test Device 4: BBa_J364007 </li>
 +
<li> Test Device 5: BBa_J364008 </li>
 +
<li> Test Device 6: BBa_J364009 </li>
 +
<ul>
 +
 +
 +
 +
</div>
  
 
<!--
 
<!--

Revision as of 04:20, 31 July 2018

★ ALERT!

This page is used by the judges to evaluate your team for the medal criterion or award listed below.

Delete this box in order to be evaluated for this medal criterion and/or award. See more information at Instructions for Pages for awards.

Background

The Fifth International InterLaboratory Measurement Study is one of the largest collaborative studies ever performed in synthetic biology, featuring the work of iGEM teams across the world. Each annual iteration of the study is dedicated to identifying and rectifying sources of variability in measurements and protocols across lab settings. This year’s edition primarily focused on standardizing absorbance and fluorescence measurements of GFP-expressing bacteria, correcting for human and machine variability across labs.

Per the iGEM protocol, we transformed New England Biosciences 5-alpha E. coli with the eight following plasmids from the iGEM Distribution Kit 7:

  • Positive Control: BBa_I20270
  • Negative Control: BBa_R0040
  • Test Device 1: BBa_J364000
  • Test Device 2: BBa_J364001
  • Test Device 3: BBa_J364002
  • Test Device 4: BBa_J364007
  • Test Device 5: BBa_J364008
  • Test Device 6: BBa_J364009