Line 723: | Line 723: | ||
<h7><ins>Microfluidic Chip</ins></h7> | <h7><ins>Microfluidic Chip</ins></h7> | ||
− | <br> | + | <br><br> |
<h2>Designing the microfluidic chip involved meeting the regulations and requirements given by different parts of the project. Through our ideation process, we wanted a relatively cheap chip that could be easily used by end-users, which meant that the chip needed to be filled with the sample with a simple motion while avoiding contamination during the process. It also had to be portable and the results needed to be visible relatively easily. There were also specific requirements to ensure that LAMP/RPA reactions occurs properly. The reaction wells needed to have a 25um volume at least and the chip also needed to be able to withstand and transfer heat well. Engineering requirements from other parts of the Pathogene device was also present. The chip had to fit well on the heater and needed to be easily visible within the device. For the purpose of fitting well on a square heater, being easily visible, and making sure that each sample would arrive at the reaction well at the same time, the chip had a radial design. The circular chip had a circular inlet in the middle. The reactions wells were around the edges of the chip connected to the inlet by small channels.</h2> | <h2>Designing the microfluidic chip involved meeting the regulations and requirements given by different parts of the project. Through our ideation process, we wanted a relatively cheap chip that could be easily used by end-users, which meant that the chip needed to be filled with the sample with a simple motion while avoiding contamination during the process. It also had to be portable and the results needed to be visible relatively easily. There were also specific requirements to ensure that LAMP/RPA reactions occurs properly. The reaction wells needed to have a 25um volume at least and the chip also needed to be able to withstand and transfer heat well. Engineering requirements from other parts of the Pathogene device was also present. The chip had to fit well on the heater and needed to be easily visible within the device. For the purpose of fitting well on a square heater, being easily visible, and making sure that each sample would arrive at the reaction well at the same time, the chip had a radial design. The circular chip had a circular inlet in the middle. The reactions wells were around the edges of the chip connected to the inlet by small channels.</h2> | ||
<br> | <br> | ||
Line 746: | Line 746: | ||
<h7><ins>Sample Collector</ins></h7> | <h7><ins>Sample Collector</ins></h7> | ||
− | <br> | + | <br><br> |
<h2>The sample collection and preparation method used by the previous iGEM NYUAD Team involves the use of a sterile medical swab to brush the sample, swirling it inside a pre prepared solution inside a Pasteur Pipette and loading the sample using a pipette. This method requires training, careful usage, many separate pieces and both hands. Our design for the sample collector device is portable, sturdy, requires minimal training and has a mostly one handed use. Furthermore, it is cheap to produce. We achieved this design by first identifying the working principles of a pen-like design and tested them using small scale rapid prototyping and and 3D printing for more complicated structures. | <h2>The sample collection and preparation method used by the previous iGEM NYUAD Team involves the use of a sterile medical swab to brush the sample, swirling it inside a pre prepared solution inside a Pasteur Pipette and loading the sample using a pipette. This method requires training, careful usage, many separate pieces and both hands. Our design for the sample collector device is portable, sturdy, requires minimal training and has a mostly one handed use. Furthermore, it is cheap to produce. We achieved this design by first identifying the working principles of a pen-like design and tested them using small scale rapid prototyping and and 3D printing for more complicated structures. | ||
</h2> | </h2> | ||
Line 752: | Line 752: | ||
<br> | <br> | ||
<img src="https://static.igem.org/mediawiki/2018/2/29/T--NYU_Abu_Dhabi--design5.JPG"class="center"> | <img src="https://static.igem.org/mediawiki/2018/2/29/T--NYU_Abu_Dhabi--design5.JPG"class="center"> | ||
− | |||
<h2><center><i>Figure 5. Identification of sample collector working principle | <h2><center><i>Figure 5. Identification of sample collector working principle | ||
</i></center></h2> | </i></center></h2> |