(2 intermediate revisions by one other user not shown) | |||
Line 217: | Line 217: | ||
<div id="NOT0" class="cd-section"> | <div id="NOT0" class="cd-section"> | ||
<div class="NOT-title"> | <div class="NOT-title"> | ||
− | <a class="NOT-title-1" style="z-index:1;border-bottom: 3px solid #131313;text-decoration: none;"> | + | <a class="NOT-title-1" style="z-index:1;border-bottom: 3px solid #131313;text-decoration: none;font-size:30px !important;">INTERLAB</a> |
</div> | </div> | ||
</div> | </div> | ||
Line 430: | Line 430: | ||
<p class="NOT-content-p NOT-margin-pUP"> | <p class="NOT-content-p NOT-margin-pUP"> | ||
<a href="https://static.igem.org/mediawiki/2018/5/55/T--BIT-China--iGEM2018-NOT-excel.xlsx" target="_Blank" | <a href="https://static.igem.org/mediawiki/2018/5/55/T--BIT-China--iGEM2018-NOT-excel.xlsx" target="_Blank" | ||
− | style="text-decoration: none;color:#131313;">Check | + | style="text-decoration: none;color:#131313;"><b>Check |
− | here for more details.</a> | + | here for more details.</b></a> |
</p> | </p> | ||
</div> | </div> |
Latest revision as of 01:12, 18 October 2018
Interlab is aimed to improve reproducibility and compare the difference between laboratories. To complete this job,we make three sets of unit calibration measurements: an OD600 reference point, a particle standard curve, and a fluorescein standard curve. Completion of the calibrations will ensure that we understand the measurement process and that we can take the cell measurements under the same conditions. For the sake of consistency and reproducibility, we used E. coli K-12 DH5-alpha like other teams. Later, we conducted the CFU experiment. We count colonies for our two Positive Control (BBa_I20270) cultures and two Negative Control (BBa_R0040) cultures.
We use LUDOX CL-X (45% colloidal silica suspension) as a single point reference to obtain a conversion factor to transform your absorbance (AbS600) data from our plate reader into a comparable OD600 measurement.
We prepare a dilution series of monodisperse silica microspheres and measure the AbS600 in our plate reader. This measurement allow us to construct a standard curve of particle concentration which can be used to convert Abs600 measurements to an estimated number of cells.
$\surd$ Prepare the Microsphere Stock Solution
$\surd$ Prepare the serial dilution of Microspheres
$\surd$ Measure AbS600 of all samples in instrument
We will prepare a dilution series of fluorescein in four replicates and measure the fluorescence in a 96 well plate in our plate reader. By measuring these in our plate reader,we generate a standard curve of fluorescence for fluorescein concentration. Thus we are able to use this to convert our cell based readings to an equivalent fluorescein concentration.
$\surd$ Prepare the fluorescein stock solution
$\surd$ Prepare the serial dilutions of fluorescein
$\surd$ Measure fluorescence of all samples in instrument
For all of these cell measurements, we use the same plates and volumes that we used in our calibration protocol. For the first time,we have measurements that are off scale (“OVERFLOW”), so we adjust our settings to make the data in range. Finally, we get the right data.
$\surd$ Transform Escherichia coli DH5α with these following plasmids
Negative control | BBa_R0040 | Kit Plate 7 Well 2D |
Positive control | BBa_I20270 | Kit Plate 7 Well 2B |
Test Device 1 | BBa_J364000 | Kit Plate 7 Well 2F |
Test Device 2 | BBa_J364001 | Kit Plate 7 Well 2H |
Test Device 3 | BBa_J364002 | Kit Plate 7 Well 2J |
Test Device 4 | BBa_J364007 | Kit Plate 7 Well 2L |
Test Device 5 | BBa_J364008 | Kit Plate 7 Well 2N |
Test Device 6 | BBa_J364009 | Kit Plate 7 Well 2P |
$\surd$ Pick 2 colonies from each of the transformation plates and inoculate in 5-10 mL LB medium +Chloramphenicol. Grow the cells overnight (16-18 hours) at 37°C and 220 rpm
$\surd$ Cell growth, sampling, and measurement
This procedure is used to calibrate OD600 to colony forming unit (CFU) counts, which are directly relatable to the cell concentration of the culture. For the CFU protocol, we count colonies for our two Positive Control (BBa_I20270) cultures and two Negative Control (BBa_R0040) cultures.
$\surd$ Starting Sample Preparation
$\surd$ Dilution Series Instructions
$\surd$ Calculation