Protocols
Agarose Gel Electrophoresis
Materials:
agarose 0.25g TAE 25mL GelRed 2uL 6× Gel loading Dye DNA marker 4ul
Methods:
- Heat the mixture until no particle can be seen.
- Add GelRed when the temperature drops to around 55℃.
- Pour the solution into the gel casting tray with appreciate comb.
- Place the gel in the electrophoresis chamber and add enough TAE Buffer.
- Add 6× Gel loading Dye into the samples and load them. 130V, 15min of electrophoresis.
- Staining and visualization.
Notes:
The concentration of gel affects the resolution of DNA separation. For a standard agarose gel electrophoresis, a 0.8% gives good separation or resolution of large 5–10kb DNA fragments, while 2% gel gives good resolution for small 0.2–1kb fragments. 1% gels is often used for a standard electrophoresis.A-T Ligation
Materials:
PCR product x ng pClone007 Blunt Simple Vector 1ul 10×Topo Mix 1ul ddH2O up to 10ul
Size of inserted fragment (bp) | x (ng) |
100-1000 | 10-50 |
1000-2000 | 50-100 |
2000-5000 | 100-200 |
Methods:
Keep materials at room temperature (22-30℃) for 1-5 min.Notes:
- The materials should not be put on ice after ligation.
- The PCR product should use taq DNA polymerase. Otherwise they should be added into the taq DNA polymerase system and incubate in 37℃ for 10min.
BioBrick Ligation
Materials:
Linear vector DNA 20-100ng Insert DNA 5:1molar ratio over vector 10× T4 DNA Ligase Buffer 2uL T4 DNA Ligase 1 Weiss U ddH2O up to 20uL Total volume 20uL
Methods:
- Incubate 10 min at 22℃.
- Use up to 5uL of the mixture for transformation of 50uL of chemically competent cells or 1-2uL per 50uL of electrocompetent cells.
Notes:
- The electrotransformation efficiency may be improved by:
- Heat inactivation of T4 DNA ligase at 65℃ for 10 min or at 70℃ for 5 min.
- Purification of DNA.
- The overall number of transformants may be increased by extending the reaction time to 1 hour.
- If more than 2 Weiss U of T4 DNA ligase is used in 20uL reaction mixture, it is necessary to purify DNA before electrotransformation.
Chemical Transformation
Materials:
DH5α component cell DNA plasmid LB media The selection plates
Methods:
- Retrieve 1 tube of E. coli DH5α component cell on ice.
- Add 10ng DNA plasmid into the tube.
- Place the mixture on ice for 30 minutes.
- Heat shock in 42℃ water bath for 45 seconds.
- Place the mixture on ice for 2 minutes.
- Pipette 900μl of LB media into the mixture.
- Incubate at 37℃ and 220 rpm for 1 hour.
- Centrifuge 5000 rpm for 2 minutes.
- Aspirate the supernatant liquid and resuspend the bacteria in LB media.
- Add them to the selection plate.
Colony PCR
Materials:
2x Taq Master Mix 10μl Primer F 1μl Primer R 1μl Bacteria cultures 1μl dd H2O up to 20μl
Methods:
- Keep materials on ice, pipette reagents into a 100μl Eppendorf tubes.
- Gently mix the reaction. Do not vortex the tube.
- Use the centrifuge to collect all liquid to the bottom of the tube.
- Put Eppendorf tubes into the thermocycler and set up the program.
Program:
}
94℃ 5min94℃ 30s
56℃ 30s 35 cycles
72℃ 60s/kb
72℃ 7min
8℃ ∞
Gel purification with Tiangen Gel Extraction kit
Materials:
Buffer BL Buffer PN Buffer PW Buffer EB Spin columns CA2 2mL Collection Tubes
Methods:
- Excise the DNA fragment from the agarose gel with a clean shaver blade;
- Weigh the gel slice in a 1.5ml microcentrifuge tube. Add 1 volumes of Buffer PN to the same volume of gel (0.1g gel slice is treated as100μL buffer PN).
- Incubate at 65°C for 10 min (or until the gel slice has completely dissolved). To help dissolve gel, mix by inverting the tube several times every 2–3 min during the incubation.
- Add 500μl buffer BL to a column, centrifuge at 12000rpm for 1 min and discard flow through before use to maximally activate the column.
- After the gel slice has dissolved completely, wait until the sample returns to room temperature and apply the sample to the column, let stand for 2min; Centrifuge at 1200rpm for 1 min and discard the flow-through.
- Wash the column by adding 600μl buffer PW and centrifuging for 60s. Discard the flow-through.
- Repeat the last step.
- Centrifuge for 2 min to remove the residual wash buffer.
- Place the column in a clean 1.5ml microcentrifuge tube and add 30-40μl ddH2O to the center of the column; Let stand for 2min and centrifuge for 2min; (If necessary, repeat this step).
Gibson Assembly
Materials:
Linear vector plasmid 100ng Insert fragment 10:1 mole ratio (fragment to vector) 2xSoSoo Mix 5μl ddH2O up to 10μl
Methods:
- o
- Keep materials on ice, pipette reagents into a 100μl Eppendorf tubes.
- Gently mix the reaction. Do not vortex the tube.
- Use the centrifuge to collect all liquid to the bottom of the tube.
- Put Eppendorf tubes into the thermocycler and set up the program.
Program:
50℃ 1h
8℃ ∞
8℃ ∞
Golden Gate Assembly
Materials:
The relative molecular weights of DNA per base pair is 650Da. The length of the DNA (fragment or plasmid) is L bp. Then the DNA amount needed is:ddH2O up to 20ul T4 ligase buffer 2ul vector plasmid 10^10 insert fragment 10^10 x2 BsaI 1ul T4 ligase 1ul
Fragment:
Plasmid:
Methods:
- Keep materials on ice, pipette reagents into a 100μl Eppendorf tubes.
- Gently mix the reaction. Do not vortex the tube.
- Use the centrifuge to collect all liquid to the bottom of the tube.
- Put Eppendorf tubes into the thermocycler and set up the program.
Notes:
The Plasmid and/or the fragment should obtain Golden Gate restriction site.PCR Program:
}
37℃ 15min16℃ 10min 10 cycles
37℃ 10min
65℃ 10min
80℃ 10min
12℃ ∞
PCR Using Phanta Super-Fidelity DNA Polymerase
Materials:
ddH2O up to 20ul 5×SF buffer 4ul dNTPs Mix 0.4ul Primer F 0.8ul Primer R 0.8ul Template DNA 100ng DMSO (optional) 4ul Polymerase 0.4ul
Methods:
- Keep materials on ice, pipette reagents into a 100μl Eppendorf tubes.
- Gently mix the reaction. Do not vortex the tube.
- Use the centrifuge to collect all liquid to the bottom of the tube.
- Put Eppendorf tubes into the thermocycler and set up the program.
PCR Program:
}
95℃ 3min95℃ 10s
56℃ 20s 33 cycles
72℃ 2min
72℃ 10min
4℃ ∞
Plasmid extraction
Purification of plasmid using TIANGEN pure low copy plasmid kit
Materials:
Buffer BL buffer P1 Buffer P2 Buffer P3 Buffer PW Spin columns CP3 2mL Collection TubesMethods:
- Column equilibration: Place a Spin Column CP3 in a clean collection tube, and add 500 μl Buffer BL to CP3. Centrifuge for 1 min at 12,000 rpm (~13,400 × g) in a table-top microcentrifuge. Discard the flow-through and set the Spin Column CP3 back into the collection tube.
- Harvest 1-5 ml bacterial cells in a microcentrifuge tube by centrifugation at 12,000 rpm (~13,400× g) in a conventional, table-top microcentrifuge for 1 min at room temperature (15-25°C), then remove all traces of supernatant by inverting the open centrifuge tube until all medium has been drained.
- Resuspend pelleted bacterial cells in 250 μl Buffer P1. Note: Ensure that RNase A has been added to Buffer P1. No cell clumps should be visible after resuspension of the pellet.
- Add 250 μl Buffer P2 and mix thoroughly by inverting the tube 6-8 times. Note: Mix gently by inverting the tube. Do not vortex, as this will result in shearing of genomic DNA. If necessary, continue inverting the tube until the solution becomes viscous and slightly clear. Do not allow the lysis reaction to proceed for more than 5 min. If the lysate is still not clear, please reduce bacterial pellet.
- Add 350 μl Buffer P3 and mix immediately and thoroughly by inverting the tube 6-8 times. The solution should become cloudy. Note: To avoid localized precipitation, mix the solution thoroughly, immediately after addition of Buffer P3.
- Centrifuge for 10 min at 12,000 rpm (~13,400× g) in a table-top microcentrifuge. A compact white pellet will form.
- Carefully transfer the supernatant from step 6 to the Filtration Columns CS (place the CS in a collection tube) by decanting or pipetting. Centrifuge for 2 min at 12,000 rpm (~13,400× g). Note: Avoid pipetting out the precipitate.
- Transfer the flow-through in the collection tube to the Spin Column CP3 by decanting or pipetting. Centrifuge for 1 min at 12,000 rpm (~13,400× g). Discard the flow-through and set the Spin Column CP3 back into the Collection Tube.
- Recommended: Wash the Spin Column CP3 by adding 500 µl Buffer PD and centrifuging for 1 min at 12,000 rpm (~13,400× g). Discard the flow-through and set the CP3 back into the Collection Tube. Note: This step is necessary to remove trace nuclease activity when using end A+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, which have high levels of nuclease activity or high carbohydrate content.
- Wash the Spin Column CP3 by adding 600 µl Buffer PW (ensure the ethanol (96%-100%) has been added to Buffer PW) and centrifuging for 1 min at 12,000 rpm (~13,400× g). Discard the flow-through and set the CP3 back into the Collection Tube.
- Wash Spin Column CP3 by adding 600 µl Buffer PW and centrifuging for 1 min at 12,000 rpm (~13,400× g).
- Discard the flow-through, and centrifuge for an additional 2 min at 12,000 rpm (~13,400× g) to remove residual wash buffer PW. Note: Residual wash buffer will not be completely removed unless the flow-through is discarded before this additional centrifugation. We suggest open CP3 lid and stay at room temperature for a while. Residual ethanol from Buffer PW may inhibit subsequent enzymatic reactions.
- Place the Spin Column CP3 in a clean 1.5 ml microcentrifuge tube. To elute DNA, add 30-50 μl water (pH 7.0-8.5) to the center of the Spin Column CP3, let stand for 2-5 min, and then centrifuge for 2 min at 12,000 rpm (~13,400×g)
Notes:
- Add the provided Rnase A solution to buffer P1, mix and store at 2-8℃
- Check Buffer BL, P2 and P3 before use for salt precipitation. If necessary, dissolve the buffer by warming at 37 ℃ for several minutes.
- Avoid direct contact Buffer P2 and P3, immediately close the lid after use.
- All centrifugation steps are carried out at 12000rpm(~13,400×g) in table-tap microcentrifuge at room temperature (15-25℃)
- After treated with Buffer BL, use the Spin column soon, otherwise long-term placement may affect the purifying effect.
- Add ethanol to Buffer PW before use, check bottle tag for the adding volume.
Preparation of LB Medium
Materials:
Yeast extract 5g Tryptone 10g NaCl 10g H2O up to 1L Agar powder (for agar plate) 20g
Methods:
- Add reagents into an Erlenmeyer.
- Autoclave at 121 °C for 20 min.
Preparation of Minimal Medium
Minimal Medium:
Notes:
- Solvent of component I II are water; Solvent of component III IV is 1 mol/L HCl.
- Component III decomposes easily under light. Please put it into Brown grinding reagent bottle.
- Components I III and V need to be sterilized at 121°C separately to prevent reaction between component.
Coupling Circuit
Evolving Circuit
Selecting Circuit
Sensing Circuit