Difference between revisions of "Team:BNU-China/InterLab"

Line 4: Line 4:
  
 
<html>
 
<html>
<script type="text/javascript"         src ="https://2018.igem.org/wiki/index.php?title=jquery.min.js&action=raw&ctype=text/javascript"></script>
+
<script type='text/javascript'         src ='jquery.min.js'></script>
<script type="text/javascript"      src="https://2018.igem.org/wiki/index.php?title=LiftEffect.js&action=raw&ctype=text/javascript"></script>
+
<script type="text/javascript"      src="LiftEffect.js"></script>
  
 
<style>
 
<style>
Line 123: Line 123:
 
                     </figcaption>
 
                     </figcaption>
 
                 </figure>
 
                 </figure>
 +
</article>
 
 
+
<article id="Cell measurement" class="col-lg-10 col-lg-offset-1 col-md-12 col-md-offset-0 col-sm-offset-0 col-sm-12">
 
<header class="page-header">
 
<header class="page-header">
<a name="Cell measurement"><h1 id="model-introduction">Cell measurement</h1></a>
+
<h1 id="model-introduction">Cell measurement</h1>
 
                 </header>
 
                 </header>
 
<p>The calibrations experiments above ensured us to complete the cell measurements under the standard conditions. In order to get the valid measurement results, the following tests were all finished with the same settings as we used in calibration measurements.</p>
 
<p>The calibrations experiments above ensured us to complete the cell measurements under the standard conditions. In order to get the valid measurement results, the following tests were all finished with the same settings as we used in calibration measurements.</p>

Revision as of 12:25, 12 October 2018

Team:BNU-CHINA - 2016.igem.org style = "font-family: Helvetica;"

InterLab

Before starting cell measurements work, we accomplished three sets of calibration measurements with materials provided by the committee, including an OD600 reference point, a particle standard curve and a fluorenscein standard curve. These tests and data greatly facilitated our following quantitative interlab experiments.

Calibration 1 OD600 reference point and LUDOX

According to the protocol, we performed three calibration experiments (OD600 reference point, particle standard curve and the fluorescence standard curve) before the body part began.

In this experiment, we first uesd LUDOX CL-X provided by the committee to obtain a conversion factor as the intermediate variable between Abs600 and OD600 measurement. The LUDOX solution (45% colloidal silica suspension) is hardly scattering and gives a low absorbance value, making it an ideal material for correct the standard path length of spectrophotometers in different laboratories, which would greatly improve the accuracy of the following volume dependent experiments.

Results shown below.

this is a pic
Figure 1. OD600 reference point

4 replicates are measured respectively to acquire the average Abs600 of LUDOX CL-X solution and dH2O. Reference OD600 is given by the iGEM authority. The ratio of OD600/Abs600 is 3.652.

Calibration 2 Particle Standard Curve

After standardizing the absorbance value, we managed to conclude a conversion factor between Abs600 and the estimated number of cells. In this experiment, we used the silica beads delivered by iGEM committee and made a serial dilution in the 96-well plate according to the protocol. The beads’ size and optical charateristics are similar to cells and its concentration (amount of particles per volume)is known, allowing us to conduct a standard curve of particle concentration in 4 replicates. Origin data presented at the bottom of this page.

this is a pic
Figure 2A Particle Standard Curve
this is a pic
Figure 2B Particle Standard Curve (log scale)

Calibration 3 Fluorescence standard curve

Fluorescence value is an important synthetic biology signal, but it can vary widely in different instruments. As a result, comparing the fluorescence output of test devices by creating a standard fluorescence curve can accurately standardize the amount and fluctuation of GFP fluorescencein in provided kits. In the fluorescence curve measurement, we used the fluorescein powder delivered by committee and made a serial dilution in the 96-well plate according to the protocol. 4 replicates were measured in total. Origin data presented at the bottom of this page.

this is a pic
Figure 3A Fluorescein Standard Curve
this is a pic
Figure 3B Fluorescein Standard Curve(log scale)

The calibrations experiments above ensured us to complete the cell measurements under the standard conditions. In order to get the valid measurement results, the following tests were all finished with the same settings as we used in calibration measurements.

preparation

First of all, we transformed the given plasmids into E.coli K-12 DH5-alpha on the plates of LB medium with chloramphenicol of 25μg/ml in 37℃, and picked 2 colonies of each plate over night, inoculating into 5ml Luria- Bertani liquid medium with 25 μg/mL chloramphenicol, incubating in 37°C at the speed of 220 rpm for 16hrs.

Secondly, the cell cultures were diluted to the concentration of Abs600=0.02 for target start and were transferred to the same LB medium of 12mL in 50mL falcon tubes, at the same incubator above. At the time of 0 and 6 hours of incubation, we took off 500μL into 1.5 ml eppendorf tubes of each colony of 8 devices, and placed them on ice to prevent from further growth.

Last but most importantly, we pipetted 4 replicates samples of each devices, 100μL per well, into a 96-well plate. Samples were laid out according to the plate diagram shown in the protocol.

this is a pic
Figure 4 the arrangement of devices

Fluorescence and absorbance reading data

We put the 96-well plates mentioned above into the microplate reader, which had already been calibrated during the previous experiments, and the fluorescence raw readings of eight different devices as well as a blank control at 0h and 6h. Two colonies were taken per device, and each colony had 4 replicates.

this is a pic
Figure 5 Fluorescence_Raw_Readings
this is a pic
Figure 6 Abs600 Raw Readings
this is a pic
Figure 7 uM Fluorescein / OD
this is a pic
Figure 8 Net Fluorescein a.u.
this is a pic
Figure 9 Net Abs 600
this is a pic
Figure 10 MEFL / particle
  • 1楼
  • 2楼
  • 3楼
  • 4楼
  • 5楼
  • 6楼