Difference between revisions of "Team:BJRS China/InterLab"

m
Line 24: Line 24:
 
background-image:url(https://static.igem.org/mediawiki/2018/c/c4/T--BJRS_China--wikibg7v4.jpeg);
 
background-image:url(https://static.igem.org/mediawiki/2018/c/c4/T--BJRS_China--wikibg7v4.jpeg);
 
background-attachment: fixed;
 
background-attachment: fixed;
         background-size:1440px 1080px;
+
         background-size:1340px 980px;
 
         background-repeat:no-repeat;
 
         background-repeat:no-repeat;
 
}
 
}
Line 108: Line 108:
 
       <hr class="line">
 
       <hr class="line">
  
<div style="padding-left:170px;padding-right:170px;color:black">
+
<div style="padding-left:180px;padding-right:180px;color:black">
 
<h1>Preparation</h1>
 
<h1>Preparation</h1>
 
                         <h2>What Is Interlab?</h2>
 
                         <h2>What Is Interlab?</h2>

Revision as of 05:30, 17 October 2018

BJRS

InterLab


Preparation

What Is Interlab?

This is the 5th year of InterLab and we have the following question: Can we reduce lab-to-lab variability in fluorescence measurements by normalizing to absolute cell count or colony-forming units (CFUs) instead of OD?

Materials

DNA/Plasmids

  1. Negative Control: BBa_R0040
  2. Positive Control: BBa_I20270
  3. Test Device 1: BBa_J364000
  4. Test Device 2: BBa_J364001
  5. Test Device 3: BBa_J364002
  6. Test Device 4: BBa_J364007
  7. Test Device 5: BBa_J364008
  8. Test Device 6: BBa_J364009

Apparatus

  • 96 well plates (provided by Peking University)
  • Plate reader
  • Foil covered 50 ml tube
  • Eppendorf tubes
  • Pipettes

Materials

  • LUDOX CL-X
  • Silica beads
  • Fluorescein
  • Phosphate buffered saline
  • LB media
  • Chloramphenicol
  • LB plates
  • distilled water

Protocols

We followed the protocol provided by iGEM HQ so that inter-laboratory errors can be reduced. Protocols we used can be found here:

2018 InterLab Plate Reader Protocol
Help: Protocols/Transformation

Results

The results are shown in the tables and figures.

I.Calibrations

OD600 reference point:

Table 1. OD600 Reference Point.

OD<sub>600</sub> Reference Point

Particle Standard Curve

Particle Standard Curve
Figure 1. Particle Standard Curve.

Particle Standard Curve(log scale)

Particle Standard Curve(log scale)
Figure 1. Particle Standard Curve(log scale).

Fluorescein Standard Curve

Fluorescein Standard Curve
Figure 2. Fluorescein Standard Curve.

Fluorescein Standard Curve(log scale)

Fluorescein Standard Curve(log scale)
Figure 2. Fluorescein Standard Curve(log scale).

II.Cell Measurements

Fluorescence Raw

Table 2. Raw Plate Reader Measurements of Fluorescence Raw at 0 hour.

Fluorescence at 0h

Table 3. Raw Plate Reader Measurements of Fluorescence Raw at 6 hours.

Fluorescence at 6h

Abs600 Raw

Table 4. Raw Plate Reader Measurements of Abs600 Raw at 0 hour.

Abs600 at 0h

Table 5. Raw Plate Reader Measurements of Abs600 Raw at 6 hours.

Abs600 at 6h