Team:Pasteur Paris/TrainingThomas3

""

LAB SAFETY:

a time line to understand the lab worker's daily life

This role-playing shows that, during one day as a lab worker, you may have to work in laboratories with different biosafety levels. Then, a classification exists which takes into consideration the organism used, the equipment practices and procedures you have to follow. Mainly, BSL-1 and BSL-2 are used for research. However, in some important cases, you could use BSL-3 lab and more. An important point is that rules are cumulative, it means that in BSL-2 you have to apply BSL-1 rules and BSL-2 rules.

BSL-1: a basic laboratory with a biosafety level 1

This laboratory is used for basic teaching and research. In this lab, you have to use good microbiological techniques (GMT). GMT rules should be applied every time you work with any microorganism, regardless the biosafety level. No safety equipment is required except an open bench work. No isolation of laboratory is required.

BSL-2: a basic laboratory with a biosafety level 2

This laboratory is used for primary health services, diagnostic services and research. As a BSL-1 lab, you have to adopt GMT practices but also wear protective clothing. In this lab, you will see the biohazard sign. With a bench work, in this lab, you must have a class II BSC: biological safety cabinet, a protection against potential aerosols. No isolation of laboratory is required.

BSL-3: the containment laboratory with a biosafety level 3

This laboratory is used for special diagnostic services and research. You must wear special clothing. This lab is controlled for its access, and has a directional airflow. As BSL-2 lab, this lab requires a class III BSC and other primary devices for special activities. Thus, isolation of laboratory is required.

BSL-4: the maximum containment laboratory with a biosafety level 4

This laboratory is a dangerous pathogen unit. In this lab, you have an airlock entry, a shower exit and special waste disposal. Safety equipment is composed of a class III BSC with a double ended autoclave. Moreover, the air is always filtered. Thus, isolation of laboratory is required.
In this lab, you must pay attention to personnel safety monitoring capability: indeed, you must have a closed-circuit television and a two-way communication for example.

REFERENCES

World Health Organization "Laboratory Biosafety Manual. Third Edition.", Geneva (2004),http://www.who.int/csr/resources/publications/biosafety/Biosafety7.pdf