Difference between revisions of "Team:Nanjing-China/InterLab"

(Replaced content with "<p>InterLab</p>")
 
(31 intermediate revisions by 2 users not shown)
Line 1: Line 1:
<p>InterLab</p>
+
<html xmlns="http://www.w3.org/1999/xhtml">
 +
<head>
 +
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
 +
<title>Nanjing-China2018</title>
 +
<link rel="stylesheet" type="text/css" href="https://2018.igem.org/Team:Nanjing-China/CSS:2?action=raw&ctype=text/css" />
 +
<link rel="stylesheet" type="text/css" href="https://2018.igem.org/Team:Nanjing-China/CSS:loader?action=raw&ctype=text/css" />
 +
<style type="text/css">
 +
#HQ_page table p{ font-size:85%;}
 +
#HQ_page .word-note p{ text-align:center; }
 +
</style>
 +
<script type="text/javascript" src="https://2018.igem.org/Team:Nanjing-China/Javascript:1?action=raw&ctype=text/javascript"></script>
 +
<script type="text/javascript">
 +
function menuFix(){
 +
    var sfEles=document.getElementById("menu").getElementsByTagName("li");
 +
        for(var i=0;i<sfEles.length; i++){
 +
        sfEles[i].onmouseover=function(){
 +
            this.className +=(this.className.length>0?"":"")+"listshow";
 +
            }
 +
            sfEles[i].onmouseout=function(){
 +
            this.className =this.className.replace("listshow","");
 +
            }
 +
        }
 +
    }
 +
    window.onload= menuFix;
 +
function MM_changeProp(objId,x,theProp,theValue) { //v9.0
 +
  var obj = null; with (document){ if (getElementById)
 +
  obj = getElementById(objId); }
 +
  if (obj){
 +
    if (theValue == true || theValue == false)
 +
      eval("obj.style."+theProp+"="+theValue);
 +
    else eval("obj.style."+theProp+"='"+theValue+"'");
 +
  }
 +
}
 +
function MM_effectAppearFade(targetElement, duration, from, to, toggle)
 +
{
 +
Spry.Effect.DoFade(targetElement, {duration: duration, from: from, to: to, toggle: toggle});
 +
}
 +
function MM_effectBlind(targetElement, duration, from, to, toggle)
 +
{
 +
Spry.Effect.DoBlind(targetElement, {duration: duration, from: from, to: to, toggle: toggle});
 +
}
 +
</script>
 +
</head>
 +
 
 +
<body>
 +
<div id="loader">
 +
<div class="spinner">
 +
  <div class="spinner-container container1">
 +
    <div class="circle1"></div>
 +
    <div class="circle2"></div>
 +
    <div class="circle3"></div>
 +
    <div class="circle4"></div>
 +
  </div>
 +
  <div class="spinner-container container2">
 +
    <div class="circle1"></div>
 +
    <div class="circle2"></div>
 +
    <div class="circle3"></div>
 +
    <div class="circle4"></div>
 +
  </div>
 +
  <div class="spinner-container container3">
 +
    <div class="circle1"></div>
 +
    <div class="circle2"></div>
 +
    <div class="circle3"></div>
 +
    <div class="circle4"></div>
 +
  </div>
 +
</div>
 +
</div>
 +
<script type="text/javascript">
 +
            $(window).load(function() {
 +
                $("#loader").fadeOut("slow");
 +
            })
 +
</script>
 +
<div id="d">
 +
<img src="https://static.igem.org/mediawiki/2018/f/fe/T--Nanjing-China--signal-1.jpg" width="100%" onclick="MM_effectBlind('HOME', 1000, '0%', '100%', true)" />
 +
<div align="center">
 +
<div id="HOME">
 +
    <div class="sub">
 +
      <ul><li><a href="https://2018.igem.org/Team:Nanjing-China/InterLab">InterLab</a></ul></li></div>
 +
      <ul>
 +
    <li><a href="#summary">Summary</a></li>
 +
    <li><a href="#problems">Problems</a></li>
 +
            <li><a href="#details">Details</a></li></ul>
 +
</div>
 +
</div>
 +
</div>
 +
<div id="for_judge" align="center"><div class="i"><ul><a href="https://2018.igem.org/Team:Nanjing-China/For_Judges"><strong>For_judges</strong></a></ul></div></div>
 +
<div class="container" align="center">
 +
<div id="menu" >
 +
        <ul>
 +
  <li><a href="https://2018.igem.org/Team:Nanjing-China">N<font size="-1"><sub>2</sub></font> CHASER</a>
 +
    <ul>
 +
        <li><a href="https://2018.igem.org/Team:Nanjing-China/Team">Team</a></li>
 +
            <li><a href="https://2018.igem.org/Team:Nanjing-China/Members">Members</a></li>
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/Attributions">Attributions</a></li>
 +
            <li><a href="https://2018.igem.org/Team:Nanjing-China/For_Judges">For_Judges</a></li>
 +
</ul>
 +
    </li>
 +
        <li><a href="https://2018.igem.org/Team:Nanjing-China/Background">PROJECT</a>
 +
    <ul>
 +
            <li><a href="https://2018.igem.org/Team:Nanjing-China/Background">Background</a></li>
 +
        <li><a href="https://2018.igem.org/Team:Nanjing-China/Design">Design</a></li>
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/Results">Results</a></li>
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/Demonstrate"><font size="-0.1">Demonstrate</font></a></li>
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/Hardware">Hardware</a></li> 
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/InterLab">InterLab</a></li>
 +
</ul>
 +
        </li>
 +
    <li><a href="https://2018.igem.org/Team:Nanjing-China/Parts">PARTS</a>
 +
        <ul>
 +
        <li><a href="https://2018.igem.org/Team:Nanjing-China/Basic_Part">Basic_Part</a></li>
 +
        <li><a href="https://2018.igem.org/Team:Nanjing-China/Composite_Part">Composite</a></li>
 +
            <li><a href="https://2018.igem.org/Team:Nanjing-China/Improve">Improve</a></li>
 +
</ul>
 +
            </li>
 +
    <li><a href="https://2018.igem.org/Team:Nanjing-China/Model">MODELING</a></a>
 +
      </li>
 +
    <li><a href="https://2018.igem.org/Team:Nanjing-China/Human_Practices">PRACTICES</a>
 +
    <ul>
 +
        <li><a href="https://2018.igem.org/Team:Nanjing-China/Human_Practices"><font size="-1">Human_Practices</font></a></li>
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/Safety">Safety</a></li>
 +
                <li><a href="https://2018.igem.org/Team:Nanjing-China/Collaborations"><font size="-0.1">Collaboration</font></a></li>
 +
</ul>
 +
    </li>
 +
    <li><a href="https://2018.igem.org/Team:Nanjing-China/Notebook">NOTEBOOK</a></li>
 +
      </ul>
 +
  </div>
 +
  <div class="header"><img src="https://static.igem.org/mediawiki/2018/4/40/T--Nanjing-China--title-4.png" width="100%"  onload="MM_effectAppearFade(this, 1000, 0, 100, false);MM_effectBlind('HOME', 1000, '0%', '100%', true)">
 +
</div>
 +
    <div class="contain">
 +
    <div class="word">
 +
      <div style="position:absolute; top:-90px; z-index:3; left:-10px;">
 +
    <img src="https://static.igem.org/mediawiki/2018/3/35/T--Nanjing-China--PROJECT-i.png" width="45%" /></div>
 +
    </div>
 +
    <div class="word" id="summary">
 +
    <h2>Summary</h2>
 +
      <p>Our team  Nanjing-China used <em>E. coli</em> K-12 DH5-alpha to conduct the InterLab Study. The instrument used during our measurements is Tecan Infinite M1000  Pro plate reader which could read both fluorescence and absorbance from the  top of the plate. It has variable temperature settings and pathlength correction, which can  be disabled. By using this instrument, we have  accomplished assignments according to the PLATE READER AND CFU PROTOCOL, and  our data has also been accepted.</p>
 +
      </div>
 +
      <div class="word" id="problems">
 +
    <h2>Problems: </h2>
 +
      <p>Although we successfully  completed the InterLab study ultimately, during the process we also faced some  problems which quite puzzled us. </p>
 +
      <p>At first, we didn&rsquo;t  understand the purpose of InterLab and were quite confused how to start this  project. But fortunately we solved these problems with the assistance from  Vinoo Selvarajah, the Director of the Registry and iGEM HQ Representative for  the 2018 competition and began this project.</p>
 +
      <p>Yet, due to the  ignorance of instrumental usage, we were upset by the problem of properly using  the plate reader. And our data is not correct because  of the improper manipulation. With the help of our secondary PI Peiqing Sun and  our advisor Kunlun Li, we finally obtained the correct data and the data were  accepted successfully.</p>
 +
      <p>During the process  of accomplishing the InterLab project, we experienced success and failure, we  have also learned plenty of things, such as the manipulation of some  instruments, scientific methods and so on.</p>
 +
    </div>
 +
    <div class="word" id="details">
 +
      <h2>Details</h2>
 +
        <h3><u>Calibration Protocols</u></h3>
 +
        <p>We used black plates with transparent bottom for the calibration  measurements, which had flat-bottomed wells.</p>
 +
  <h3><u>Calibration 1: OD600 Reference point - LUDOX  Protocol</u></h3>
 +
      <div class="word-note" align="center">
 +
        <table border="1" cellspacing="0" cellpadding="0" width="0">
 +
          <tr>
 +
            <td width="109" valign="bottom"><p>&nbsp;</p></td>
 +
            <td width="90" valign="bottom"><p align="center">LUDOX CL-X </p></td>
 +
            <td width="90" valign="bottom"><p align="center">H<sub>2</sub>O </p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Replicate 1 </p></td>
 +
            <td width="90"><p align="center">0.0506 </p></td>
 +
            <td width="90"><p align="center">0.0372 </p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Replicate 2 </p></td>
 +
            <td width="90"><p align="center">0.050799999 </p></td>
 +
            <td width="90"><p align="center">0.0353 </p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Replicate 3 </p></td>
 +
            <td width="90"><p align="center">0.0517 </p></td>
 +
            <td width="90"><p align="center">0.033100002 </p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Replicate 4 </p></td>
 +
            <td width="90"><p align="center">0.050500002 </p></td>
 +
            <td width="90"><p align="center">0.034600001 </p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Arith. Mean </p></td>
 +
            <td width="90" valign="bottom"><p align="center">0.051 </p></td>
 +
            <td width="90" valign="bottom"><p align="center">0.035 </p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Corrected Abs600 </p></td>
 +
            <td width="90" valign="bottom"><p align="center">0.016 </p></td>
 +
            <td width="90"><p>&nbsp;</p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">Reference OD600 </p></td>
 +
            <td width="90" valign="bottom"><p align="center">0.074 </p></td>
 +
            <td width="90"><p>&nbsp;</p></td>
 +
          </tr>
 +
          <tr>
 +
            <td width="109" valign="bottom"><p align="left">OD600/Abs600 </p></td>
 +
            <td width="90" valign="bottom"><p align="center">4.669 </p></td>
 +
            <td width="90"></td>
 +
          </tr>
 +
        </table>
 +
      <p><font size="-1">Figure 1. OD600 Reference point</font></p>
 +
            </div>
 +
        <p>We used LUDOX CL-X as a single point reference to obtain a ratiometric  conversion factor to transform our absorbance data into a standard OD600&nbsp;measurement.&nbsp;</p>
 +
      <h3><u>Calibration  2: Particle Standard Curve - Microsphere Protocol</u></h3>
 +
      <div class="word-note">
 +
      <img src="https://static.igem.org/mediawiki/2018/d/dd/T--Nanjing-China--InterLab-1.jpg" width="70%" />
 +
      <p><font size="-1">Figure 2. Particle Standard Curve</font></p>
 +
      </div>
 +
      <div class="word-note">
 +
      <img src="https://static.igem.org/mediawiki/2018/c/c0/T--Nanjing-China--InterLab-2.jpg" width="70%" />
 +
      <p><font size="-1">Figure 3. Particle Standard Curve (log scale)</font></p>
 +
      </div>
 +
      <p align="left">We prepared a dilution series of monodisperse silica  microspheres and measure the Abs600 in our plate reader. The size  and optical characteristics of these microspheres were similar to cells, and  there was a known amount of particles per volume. This measurement would allow  us to construct a standard curve of particle concentration which could be used  to convert Abs600 measurements to an estimated number of cells.</p>
 +
        <h3><u>Calibration 3: Fluorescence standard curve - Fluorescein Protocol</u></h3>
 +
              <div class="word-note">
 +
      <img src="https://static.igem.org/mediawiki/2018/4/4e/T--Nanjing-China--InterLab-3.jpg" width="70%" />
 +
      <p><font size="-1">Figure 4. Fluorescein Standard Curve</font></p>
 +
      </div>
 +
      <div class="word-note">
 +
      <img src="https://static.igem.org/mediawiki/2018/d/d9/T--Nanjing-China--InterLab-4.jpg" width="70%" />
 +
      <p><font size="-1">Figure 5. Fluorescein Standard Curve (log scale)</font></p>
 +
      </div>
 +
      <p align="left">We prepared a dilution series of fluorescein in four  replicates and measure the fluorescence in a 96 well plate in our plate reader.  By measuring these in our plate reader, we generated a standard curve of  fluorescence for fluorescein concentration. We would be able to use this to  convert our cell based readings to an equivalent fluorescein concentration.</p>
 +
<h3><u>Cell measurement protocol</u></h3>
 +
<p>After completing all three of the calibration  measurements, we started performing the cell measurements. We use <em>E. coli</em> K-12 DH5-alpha strain, the same plates and volumes that we used in our  calibration protocol, as well as the same settings (e.g., filters or excitation  and emission wavelengths) that we used in our calibration measurements for the  sake of consistence.</p>
 +
    </div>
 +
    </div>
 +
<div class="footer">
 +
    <div align="center">
 +
      <div class="f">
 +
        <div class="f-word"><p><strong><u>Address</u></strong></p>
 +
            <p>Life Science Department<br />
 +
              #163 Xianlin Blvd, Qixia District<br />
 +
              Nanjing University<br />
 +
              Nanjing, Jiangsu Province<br />
 +
              P.R. of China<br />
 +
              Zip: 210046
 +
            </p></div>
 +
          <div class="f-word">
 +
            <p><strong><u>Email</u></strong></p>
 +
            <p>nanjing_china@163.com</p>
 +
            <p><strong><u>Social media</u></strong></p>
 +
            <p>Twitter button: <br/>
 +
            <a href="https://twitter.com/Guja1501">iGEM Nanjing-China@nanjing_china</a></p>
 +
        </div>
 +
        <div class="f-img">
 +
          <div align="center"><img src="https://static.igem.org/mediawiki/2017/0/04/T-Nanjing-China-%E5%8D%97%E4%BA%AC%E5%A4%A7%E5%AD%A6.png" name="img1" width="80" height="110" id="img1" /></div>
 +
        </div>
 +
          <div class="f-img">
 +
            <div align="right"><img src=" https://static.igem.org/mediawiki/2017/d/d4/T-Nanjing-China-%E5%9B%BE%E7%89%873.png
 +
" name="img2" width="80" height="110" id="img2" /></div>
 +
          </div>
 +
          <div class="f-img">
 +
            <div align="center"><img src="https://static.igem.org/mediawiki/2017/3/37/T-Nanjing-China-s1.png" name="img3" width="80" height="80" id="img3" /></div>
 +
          </div>
 +
          <div class="f-img">
 +
            <div align="right"><img src="https://static.igem.org/mediawiki/2017/d/dc/T-Nanjing-China-%E5%9B%BE%E7%89%872.png" name="img4" width="80" height="80" id="img4"  /></div>
 +
        </div>
 +
      </div>
 +
    </div>
 +
      <div class="f-b"><img src="https://static.igem.org/mediawiki/2018/5/58/T--Nanjing-China--footer-4.png" width="100%" /></div>
 +
  </div>
 +
</div>
 +
</body>
 +
</html>

Latest revision as of 02:34, 18 October 2018

Nanjing-China2018

Summary

Our team Nanjing-China used E. coli K-12 DH5-alpha to conduct the InterLab Study. The instrument used during our measurements is Tecan Infinite M1000 Pro plate reader which could read both fluorescence and absorbance from the top of the plate. It has variable temperature settings and pathlength correction, which can be disabled. By using this instrument, we have accomplished assignments according to the PLATE READER AND CFU PROTOCOL, and our data has also been accepted.

Problems:

Although we successfully completed the InterLab study ultimately, during the process we also faced some problems which quite puzzled us.

At first, we didn’t understand the purpose of InterLab and were quite confused how to start this project. But fortunately we solved these problems with the assistance from Vinoo Selvarajah, the Director of the Registry and iGEM HQ Representative for the 2018 competition and began this project.

Yet, due to the ignorance of instrumental usage, we were upset by the problem of properly using the plate reader. And our data is not correct because of the improper manipulation. With the help of our secondary PI Peiqing Sun and our advisor Kunlun Li, we finally obtained the correct data and the data were accepted successfully.

During the process of accomplishing the InterLab project, we experienced success and failure, we have also learned plenty of things, such as the manipulation of some instruments, scientific methods and so on.

Details

Calibration Protocols

We used black plates with transparent bottom for the calibration measurements, which had flat-bottomed wells.

Calibration 1: OD600 Reference point - LUDOX Protocol

 

LUDOX CL-X

H2O

Replicate 1

0.0506

0.0372

Replicate 2

0.050799999

0.0353

Replicate 3

0.0517

0.033100002

Replicate 4

0.050500002

0.034600001

Arith. Mean

0.051

0.035

Corrected Abs600

0.016

 

Reference OD600

0.074

 

OD600/Abs600

4.669

Figure 1. OD600 Reference point

We used LUDOX CL-X as a single point reference to obtain a ratiometric conversion factor to transform our absorbance data into a standard OD600 measurement. 

Calibration 2: Particle Standard Curve - Microsphere Protocol

Figure 2. Particle Standard Curve

Figure 3. Particle Standard Curve (log scale)

We prepared a dilution series of monodisperse silica microspheres and measure the Abs600 in our plate reader. The size and optical characteristics of these microspheres were similar to cells, and there was a known amount of particles per volume. This measurement would allow us to construct a standard curve of particle concentration which could be used to convert Abs600 measurements to an estimated number of cells.

Calibration 3: Fluorescence standard curve - Fluorescein Protocol

Figure 4. Fluorescein Standard Curve

Figure 5. Fluorescein Standard Curve (log scale)

We prepared a dilution series of fluorescein in four replicates and measure the fluorescence in a 96 well plate in our plate reader. By measuring these in our plate reader, we generated a standard curve of fluorescence for fluorescein concentration. We would be able to use this to convert our cell based readings to an equivalent fluorescein concentration.

Cell measurement protocol

After completing all three of the calibration measurements, we started performing the cell measurements. We use E. coli K-12 DH5-alpha strain, the same plates and volumes that we used in our calibration protocol, as well as the same settings (e.g., filters or excitation and emission wavelengths) that we used in our calibration measurements for the sake of consistence.