Campylobacter jejuni is a Gram-negative, microaerophilic, corkscrew-shaped bacteria which has been implicated as being one of the most common causes of human gastroenteritis worldwide. WHO estimates that 1 in 10 people around the world fall ill with a Campylobacter infection annually.[1] Infection with this bacteria in the UK was recently estimated to cost health services £50 million (in 2008-2009 prices), with a cost of £85 per case.[2]
Infection with Campylobacter causes common symptoms such as diarrhoea, abdominal pain, fever, headache, nausea and vomiting. [1] C. jejuni grows optimally between 37 and 42°C and is most commonly found on undercooked poultry, though it has been reported in other undercooked meat and meat products, raw milk, and in untreated drinking water [1]. The high prevalence of C. jejuni makes it an interesting target for synthetic biology-based solutions.
Treatment for Campylobacteriosis (Campylobacter-caused diarrhoeal disease) is generally only given in the most severe cases or when patients are vulnerable, and usually consists of giving more fluids and glucose-electrolyte solutions to ensure dehydration does not occur. [3] Erythromycin therapy can also be given but little clinical benefit is seen if the treatment is begun after four days of symptom onset. [4] However, the use of antibiotics can be recommended in the case of patients who are immunocompromised, pregnant, or with very severe symptoms.[3]
Prevention of this infection is very easy, with several strategies from the farm to the consumer recommended by WHO: [1]
Traditional methods for detection of Campylobacter include culturing a swabbed sample on selective media and incubating for 48 hours at 42°C under microaerobic conditions.
After isolating the bacteria in this way, identification through looking at the morphology and overall characteristics of the bacteria is carried out. Culture-based methods are relatively cheap to carry out and require less training than others techniques, but are incredibly time and labour intensive and therefore, in recent years, a move has been made towards use of rapid detection testing. [6]
More recently, techniques such as enzyme immunoassay and lateral flow systems have been utilised to test for Campylobacter, as they require only between one and two hours until a result is given. [7] However, use of these methods required much more highly trained employees to carry them out, and so therefore detection of Campylobacter in an industrial or agricultural setting would most likely have to be outsourced to a company specialising in these services. A particular study doing a comparison into three rapid detection systems showed a high number of false negative results, which can be considered an additional drawback when looking at detection of C. jejuni in order to reduce the incidence of disease outbreaks. [8]
In an attempt to reduce incidences of food poisoning by Campylobacter jejuni, and to improve upon current methods of detection, we decided to create a biosensor that was able to detect the presence of Campylobacter jejuni quickly and accurately. To do this we aimed to create a two part biosensor that will detect two sensory inputs. The first, xylulose, is a rare sugar most commonly associated with the pentose-phosphate pathway, where formation of xylulose-5-phosphate is an important intermediate step. Interestingly, xylulose was found incorporated into the polysaccharide capsule of Campylobacter jejuni strain RM1221 [9]. The presence of xylulose is not common in bacterial polysaccharide capsules, and additionally the glyosidic bonds which incorporate xylulose were found to be extremely acid-labile. A large focus of the project was aimed at xylulose. The other molecule we identified as a marker for Campylobacter was autoinducer-2 (AI-2). AI-2 is a secreted quorum sensing molecule. AI-2 is a significantly less specific biomarker, as many varied gram-positive and gram-negative bacterial species sense their population density and surrounding bacterial environment using this molecule [10] On the other hand, this ubiquity meant that AI-2 gene regulation was well characterised, with prior iGEM teams having worked on the natural E. coli AI-2 quorum sensing regulatory system.
For the detection of xylulose two possible avenues were explored: utilising the mannitol regulatory system from Pseudomonas fluorescens, which is known to detect xylulose but may have some off-target effects; and mutagenesis of the arabinose regulatory system from Escherichia coli, with an aim to change its target sugar to xylulose. The detectors for both xylulose and autoinducer-2 will form the two components of an AND gate that will ensure only a signal is seen when both xylulose and autoinducer-2 are present.
Regarding the application of our biosensor we went through several design iterations to create a device that would house the biosensor to make the application simple and easy. In addition to this we also looked at producing xylulose in a cheap and efficient way as the cost of xylulose held us back with regards to thorough testing of the biosensor elements. All of the above were done with thought of the implications with regards to human practices and how a genetically engineered biosensor would be received by the public.