Difference between revisions of "Team:Lambert GA/Demonstrate"

Line 308: Line 308:
 
<div id="target1"></div>
 
<div id="target1"></div>
 
<div id="subheading2"><b>Water Collection</b></div>
 
<div id="subheading2"><b>Water Collection</b></div>
<br><br>
+
<br>
 
<div id="content2">
 
<div id="content2">
 
In order to use our portable detection kit, a filtration system is needed to isolate pathogenic V. cholerae from water sources. Lambert iGEM has developed a spira swab to carry out these functions at a lower cost. The spira swab consists of a filter packed plastic bottle with a 2-cm hole at the bottom as an outlet for the filtered water. To demonstrate the in-field application of this water filtration method, Lambert iGEM ran a series of experiments to test the efficiencies of different filters (muslin filter, coffee filter, cheese filter, and t-shirt cloth) to determine which would be the most effective filter. By using water from a nearby creek and E. coli liquid cultures, these samples were filtered using the spira swabs containing different filters, and the remaining filtered water samples were plated onto carbenicillin plates. The muslin filter produced the least amount of colony forming units in comparison to the other filters demonstrating its efficiency isolating V. cholerae. Because V. cholerae is larger than E.coli, the spira swab is able to allow V. cholerae to flow through while still letting the muslin filter trap unwanted sediments and bacteria validating the effectiveness of the spira swab in our detection kit.
 
In order to use our portable detection kit, a filtration system is needed to isolate pathogenic V. cholerae from water sources. Lambert iGEM has developed a spira swab to carry out these functions at a lower cost. The spira swab consists of a filter packed plastic bottle with a 2-cm hole at the bottom as an outlet for the filtered water. To demonstrate the in-field application of this water filtration method, Lambert iGEM ran a series of experiments to test the efficiencies of different filters (muslin filter, coffee filter, cheese filter, and t-shirt cloth) to determine which would be the most effective filter. By using water from a nearby creek and E. coli liquid cultures, these samples were filtered using the spira swabs containing different filters, and the remaining filtered water samples were plated onto carbenicillin plates. The muslin filter produced the least amount of colony forming units in comparison to the other filters demonstrating its efficiency isolating V. cholerae. Because V. cholerae is larger than E.coli, the spira swab is able to allow V. cholerae to flow through while still letting the muslin filter trap unwanted sediments and bacteria validating the effectiveness of the spira swab in our detection kit.
  
  
 
+
<br><br>
 
<br>
 
<br>
 
<div style="text-align: center">
 
<div style="text-align: center">

Revision as of 19:22, 17 October 2018

D E M O N S T R A T E



































CAPTIVATE ™ Kit


In recognition of the dire crisis cholera outbreaks have presented to the world, inflicting harm on millions and killing hundreds of thousands, we present a new solution to ensure a proactive response to cholera outbreaks can be mounted by targeting contamination within the water sources. CAPTIVATE™ constitutes a portable diagnostic kit to test the water in local areas to determine whether Vibrio Cholerae is present or not. Cholera diagnosis requires This diagnostic kit includes Lambert iGEM’s hardware components such as the 3-D Fuge, Chrome-Q, Chrome-Q Base, and the Electropen System. The kit also contains the wet-lab components including the Spira Swab (gauze water filter), freeze-dried Biosensor cells in culture tubes, and a RNA extraction kit. The kit is capable of powering a phone for the Color-Q app and a cooling system needed for certain wet-lab parts of the project through a solar panel. CAPTIVATE ™ portable diagnostic kit could work in conjunction of existing World Health Organization treatment kits which can provide a more efficient assessment to determine if cholera exists in that water source.

Materials
  • Scoop (collection jar-disposable water bottle)
  • Muslin (Muslin will be placed in the 100 mL Nalgene bottle filled with diH2O: This diH2O can be obtained from boiling the water when sterilizing the muslin cloths).
  • 100 ml Nalgene bottle with 2cm.hole at the bottom (will be wrapped around with aluminum foil to keep sterile)
  • Sterile 100 mL Nalgene bottle
  • Crochet Hook, or other straight stick that can be sterilized and reused
  • lysozyme in TE buffer
  • proteinase K
  • Rneasy Mini Kit
  • 1M HCl
  • 10 ml sterile distilled H2O (1ml needed for spin columns, and disposal of biosensor cells)
  • Electropen System (Cuvette and Electropen)
  • X-gal
  • Freeze-Dried Cells in a vial
  • LB in vials
  • Culture Tubes
  • Microcentrifuge Tubes
  • PCR Tubes
  • 50 ml conical tubes
  • Lego spectrophotometer
  • 1% sodium hydrochlorite
  • 10% glycerol
  • Chrome-Q Dome & Chrome-Q base
  • Color-Q app and phone connected to the solar panel.
  • 3-D fuge
  • pipette/micropipette

Water Collection

In order to use our portable detection kit, a filtration system is needed to isolate pathogenic V. cholerae from water sources. Lambert iGEM has developed a spira swab to carry out these functions at a lower cost. The spira swab consists of a filter packed plastic bottle with a 2-cm hole at the bottom as an outlet for the filtered water. To demonstrate the in-field application of this water filtration method, Lambert iGEM ran a series of experiments to test the efficiencies of different filters (muslin filter, coffee filter, cheese filter, and t-shirt cloth) to determine which would be the most effective filter. By using water from a nearby creek and E. coli liquid cultures, these samples were filtered using the spira swabs containing different filters, and the remaining filtered water samples were plated onto carbenicillin plates. The muslin filter produced the least amount of colony forming units in comparison to the other filters demonstrating its efficiency isolating V. cholerae. Because V. cholerae is larger than E.coli, the spira swab is able to allow V. cholerae to flow through while still letting the muslin filter trap unwanted sediments and bacteria validating the effectiveness of the spira swab in our detection kit.




Picture of a Lambert iGEM member demonstrating a water collection method.


Electropen




Biosensor Cells


Freeze Drying Protocol
  1. Add 5 ml of sterile LB media and 5ul of chloramphenicol and ampicillin to a culture tube.
  2. Obtain the desired plate. Take 1-3 colonies from the biosensor cells’ plate with a sterilized inoculating loop. Stir vigorously to ensure colonies are dispensed into solution.
  3. Place culture tubes on a rack in the incubator. Set to shake and temperature to 36-38 C, and grow overnight.
  4. Centrifuge liquid culture and discard the supernatant. Resuspend the pellet in 5ml of Microbial Freeze Drying Buffer with tryptic soy broth.
  5. Aliquot 500ul of the suspension into sterile vials with stopper.
  6. Turn on the lyophilizer and start the condenser. Set the shelf to 4°C.
  7. Center the vials on the shelf. Either manually or with programmed controls, freeze the samples down to -40°C. This should take about 30-60 minutes, but it is very dependent upon the lyophilizer. If the rate of freezing can be controlled, a practical rate is to drop the temperature by 1°C per minute. The samples should be visually frozen.
  8. Let the samples sit at -40°C for 1 hour to complete freezing.
  9. Turn on the vacuum pump. Within 10-20 minutes, the vacuum should be under 200 millitorr (mtorr).
  10. After the vacuum is below 200 mtorr, increase the temperature of the shelf for primary drying. The temperature can be up to -15°C. Let continue overnight.
  11. For second drying, raise the shelf temperature to 20°C and dry for 2 hours.
  12. With the stoppering mechanism, pit the stoppers on the vacuum. Turn off vacuum.
  13. Store at 4°C in the dark.

In-Field Preparation of Cells
*Tubes should be on ice at all times unless centrifuging*
  1. Resuspend in 5 ml of LB agar. Incubate for two hour.
  2. Aliquot 1 ml of that liquid culture into 4 ml of sterile LB.
  3. Shake in an incubator overnight. If no incubator present, let sit at room temperature for a day and a half.
  4. Add the 5 ml liquid culture into 500 ml of sterile LB.
  5. Using the portable spectrophotometer, check the optical density every hour. Continue growing until the OD is 0.6.
  6. Pour cells into 50 ml conical tubes, on ice. Keep there for 30 minutes.
  7. Pipet up the bottom 1.5 ml in the tube and transfer to a microcentrifuge tube.
  8. With the 3D-fuge, centrifuge cells for 20 minutes, discard supernatant.
  9. Add 1.5 ml of ice-cold sterile into the microcentrifuge to resuspend. Add into empty 50 ml conical tube.
  10. Add another 11.5 ml of ice-cold sterile milliQ water to each conical tube, pipet up and down.
  11. Combine samples into 2 total conical tubes.
  12. Let sit on ice for 30 minutes. Take bottom 1.5 ml of each sample and transfer into a empty microcentrifuge tube.
  13. With 3D-fuge, centrifuge for 20 minutes, discard supernatant, and repeat steps 9 and 10.
  14. Let sit for 30 minutes on ice.
  15. Transfer bottom 1.5 ml into a microcentrifuge tube. Centrifuge for 20 minutes, discard supernatant, and add 1.5 ml of ice-cold 10% glycerol.
  16. Transfer the microcentrifuge into an empty conical tube. Add 23.5 ml of ice-cold 10% glycerol.
  17. Let sit for 30 minutes on ice. Repeat steps 15 and 16.
  18. Let sit for 30 minutes on ice. Take bottom 1.5 ml and transfer into a microcentrifuge tube. Centrifuge with 3D-fuge for 20 minutes.
  19. Resuspend in 1.5 ml of ice-cold 10% glycerol. Transfer into conical tube and add 2.5 ml of ice-cold 10% glycerol.
  20. Aliquot 1 ml into microcentrifuge tubes. Store in -80 freezer.