Team:NCHU Taichung/InterLab

NCHU_Taichung

Interlab

Introduction

Reliable and standardized units are key point in all disciplines. It just like a language for everyone to understand the experimental data well. Fortunately, we do have one, that is fluorescence!! fluorescence is very useful in revealing genetic function and modification. We also can use fluorescence as a marker protein, and then we can digitalize our experimental data. However, fluorescence data from different people can have diversity. So, the iGEM’s Fifth International Interlaboratory Study is to test if we can decrease the difference by normalizing to colony-forming units (CFUs) instead of OD?

Protocol

Day 1

Calibration 1:​ OD​600​ Reference point - LUDOX Protocol

Materials:

1ml LUDOX CL-X, dd H2O, 96 well plate, black with clear flat bottom preferred

Method:
  1. Add 100 μl LUDOX into wells A1, B1, C1, D1.
  2. Add 100 μl of dd H2O into wells A2, B2, C2, D2.
  3. Measure absorbance at 600 nm of all samples in the measurement mode you plan to use for cell measurements.
  4. Record the data in the table below or in your notebook.
  5. Import data into Excel sheet provided. (​OD600 reference point tab​)

Calibration 2:​ Particle Standard Curve - Microsphere Protocol

Method:
Prepare Microsphere Stock Solution:
  1. “Silica Beads” from the InterLab test kit and vortex vigorously for 30 seconds.
  2. Immediately pipet 96 μL microspheres into a 1.5 mL Eppendorf tube.
  3. Add 904 μL of dd H2O to the microspheres.
  4. Vortex well. This is your Microsphere Stock Solution.
Prepare the serial dilution of Microspheres:
  1. Add 100 μl of dd H2O​ into wells A2, B2, C2, D2....A12, B12, C12, D12.
  2. Vortex the tube containing the stock solution of microspheres vigorously for 10 seconds.
  3. Immediately add 200 μl​ ​of microspheres stock​ ​solution into A1.
  4. Transfer 100 μl of microsphere stock solution from A1 into A2.
  5. Mix A2 by pipetting up and down 3x and transfer 100 μl into A3…
  6. Mix A3 by pipetting up and down 3x and transfer 100 μl into A4...
  7. Mix A4 by pipetting up and down 3x and transfer 100 μl into A5...
  8. Mix A5 by pipetting up and down 3x and transfer 100 μl into A6...
  9. Mix A6 by pipetting up and down 3x and transfer 100 μl into A7...
  10. Mix A7 by pipetting up and down 3x and transfer 100 μl into A8...
  11. Mix A8 by pipetting up and down 3x and transfer 100 μl into A9...
  12. Mix A9 by pipetting up and down 3x and transfer 100 μl into A10...
  13. Mix A10 by pipetting up and down 3x and transfer 100 μl into A11...
  14. Mix A11 by pipetting up and down 3x and transfer 100 μl into ​liquid waste.
  15. Repeat dilution series for rows B, C, D.
Particle Standard Curve
  1. Measure Abs​600​ of all samples in instrument.
  2. Record the data in your notebook.
  3. Import data into Excel sheet provided (​particle standard curve tab​)

Calibration 3: ​Fluorescence standard curve - Fluorescein Protocol

Materials:

Fluorescein (provided in kit), 10ml 1xPBS pH 7.4-7.6, 96 well plate, black with clear flat bottom

Method:
Prepare the fluorescein stock solution:
  1. Spin down fluorescein kit tube to make sure pellet is at the bottom of tube.
  2. Prepare 10x fluorescein stock solution (100 μM) by resuspending fluorescein in 1 mL of 1xPBS.
  3. Dilute the 10x fluorescein stock solution: 100 μL of 10x fluorescein stock into 900 μL 1x PBS
Prepare the serial dilutions of fluorescein:
  1. Add 100 μl of PBS​ into wells A2, B2, C2, D2....A12, B12, C12, D12.
  2. Add 200 μl​ ​of fluorescein 1x stock​ solution into A1, B1, C1, D1.
  3. Transfer 100 μl of fluorescein stock solution from A1 into A2.
  4. Mix A2 by pipetting up and down 3x and transfer 100 μl into A3…
  5. Mix A3 by pipetting up and down 3x and transfer 100 μl into A4...
  6. Mix A4 by pipetting up and down 3x and transfer 100 μl into A5...
  7. Mix A5 by pipetting up and down 3x and transfer 100 μl into A6...
  8. Mix A6 by pipetting up and down 3x and transfer 100 μl into A7...
  9. Mix A7 by pipetting up and down 3x and transfer 100 μl into A8...
  10. Mix A8 by pipetting up and down 3x and transfer 100 μl into A9...
  11. Mix A9 by pipetting up and down 3x and transfer 100 μl into A10...
  12. Mix A10 by pipetting up and down 3x and transfer 100 μl into A11...
  13. Mix A11 by pipetting up and down 3x and transfer 100 μl into ​liquid waste.
  14. Repeat dilution series for rows B, C, D
​Fluorescence standard curve:
  1. Measure fluorescence of all samples in instrument.
  2. Record the data in your notebook.
  3. Import data into Excel sheet provided (​fluorescein standard curve tab​)

Day 2

Cell measurement protocol

Materials:

Competent cells (​ Escherichia coli strain DH5α), LB (Luria Bertani) media, Chloramphenicol (stock concentration 25 mg/mL dissolved in EtOH), 50 ml Falcon tube, 1.5 ml Eppendorf tubes for sample storage, Ice bucket with ice, Micropipettes and tips 96 well plate, black with clear flat bottom preferred, Devices (from Distribution Kit, all in pSB1C3 backbone)

Device
Device Part Number
Negative control BBa_R0040
Positive control BBa_I20270
Test device 1 BBa_J364000
Test device 2 BBa_J364001
Test device 3 BBa_J364002
Test device 4 BBa_J364007
Test device 5 BBa_J364008
Test device 6 BBa_J364009
Method:

transform ​ Escherichia coli DH5α with these following plasmids (all in pSB1C3)

Device Part Number
Negative control BBa_R0040
Positive control BBa_I20270
Test device 1 BBa_J364000
Test device 2 BBa_J364001
Test device 3 BBa_J364002
Test device 4 BBa_J364007
Test device 5 BBa_J364008
Test device 6 BBa_J364009

Day 3

Method:
  1. Pick 2 colonies from each of the transformation plates and inoculate in 5-10 mL LB medium + Chloramphenicol.
  2. Grow the cells overnight (16-18 hours) at 37°C and 220 rpm.

Day 4

Cell growth, sampling, and assay

  1. Make a 1:10 dilution of each overnight culture in LB+Chloramphenicol (0.5mL of culture into 4.5mL of LB+Chlor)
  2. Measure Abs​600​ of these 1:10 diluted cultures.
  3. Record the data in your notebook.
  4. Dilute the cultures further to a target Abs​600 of 0.02 in a final volume of ​12 ml LB medium + Chloramphenicol in 50 mL falcon tube.
  5. Take 500 µL samples of the diluted cultures at 0 hours into 1.5 ml Eppendorf tubes, prior to incubation. Place the samples on ice.
  6. Incubate the remainder of the cultures at 37°C and 220 rpm for 6 hours.
  7. Take 500 µL samples of the cultures at 6 hours of incubation into 1.5 ml Eppendorf tubes. Place samples on ice.
  8. measure your samples (Abs​600 and fluorescence measurement)
  9. Record data in your notebook.
  10. Import data into Excel sheet provided (​fluorescence measurement tab​)

Measurement

Layout for Abs​600​ and Fluorescence measurement. At the end of the experiment, you should have two plates to read. You will have one plate for each time point: 0 and 6 hours. On each plate you will read both fluorescence and absorbance.

Day 5

Colony Forming Units per 0.1 OD600 E. coli cultures

This protocol assumes that 1 bacterial cell will give rise to 1 colony.

For the CFU protocol, you will need to count colonies for your two Positive Control (BBa_I20270) cultures and your two Negative Control (BBa_R0040) cultures

Method:

Starting Sample Preparation:
  1. Add 25 μL culture to 175 μL LB + Cam in a well in a black 96-well plate, with a clear, flat bottom. Each well should have 200 μL.
  2. Dilute your overnight culture to OD600 = 0.1 in 1mL of LB + Cam media. Do this in triplicate for each culture.
  3. Check the OD600 and make sure it is 0.1.
Dilution Series Instructions
  1. You will need 3 LB Agar + Cam plates (36 total).
  2. Prepare three 2.0 mL tubes (36 total) with 1900 μL of LB + Cam media for Dilutions 1, 2, and 3.
  3. Prepare two 1.5 mL tubes (24 total) with 900 μL of LB + Cam media for Dilutions 4 and 5.
  4. Label each tube according to the figure below (Dilution 1, etc.) for each Starting Sample.
  5. Pipet 100 μL of Starting Culture into Dilution 1. Discard tip. Do NOT pipette up and down. Vortex tube for 5-10 secs.
  6. Repeat Step 5 for each dilution through to Dilution 5 as shown below.
  7. Aseptically spread plate 100 μL on LB + Cam plates for Dilutions 3, 4, and 5.
  8. Incubate at 37°C overnight and count colonies after 18-20 hours of growth.
CFU/mL/OD Calculation Instructions
  1. Count the colonies on each plate with fewer than 300 colonies.
  2. Multiple the colony count by the Final Dilution Factor on each plate.

Result

OD600 reference point

LUDOX CL-X ddH2O
Replicate 1 0.081 0.037
Replicate 2 0.090 0.036
Replicate 3 0.093 0.038
Replicate 4 0.084 0.037
Arith. Mean 0.087 0.037
Corrected Abs600 0.050
Reference OD600 0.063
OD600/Abs600 1.260

Particle standard curve

Fluorescein Standard Curve

Dilution Series Instructions

OD600 8*10^5 dilution plate 8*10^6 dilution plate CFUs 1*10^8 CFU/ml
BBa_I20270 Culture 1. Dilution Replicate 1 0.1528 716 264 211200000
BBa_I20270 Culture 1. Dilution Replicate 2 0.1531 8884 264 211200000
BBa_I20270 Culture 1. Dilution Replicate 3 0.156 854 152 121600000
BBa_I20270 Culture 2. Dilution Replicate 1 0.1402 816 146 116800000
BBa_I20270 Culture 2. Dilution Replicate 2 0.1405 836 114 91200000
BBa_I20270 Culture 2. Dilution Replicate 3 0.1409 839 102 81600000
BBa_R0040 Culture 1. Dilution Replicate 1 0.1302 629 156 124800000
BBa_R0040 Culture 1. Dilution Replicate 2 0.1305 691 188 150400000
BBa_R0040 Culture 1. Dilution Replicate 3 0.1303 634 94 75200000
BBa_R0040 Culture 2. Dilution Replicate 1 0.1188 405 223 178400000
BBa_R0040 Culture 2. Dilution Replicate 2 0.1189 367 298 238400000
BBa_R0040 Culture 2. Dilution Replicate 3 0.1190 416 367 293600000

For more detailed data, check InterLabData.xlsx